We present results from a detailed GEANT4 simulation of a proposed Muon Tomography System that employs compact Micro Pattern Gas Detectors with high spatial resolution. A basic Point-Of-Closest-Approach algorithm is applied to reconstructed muon tracks for forming 3D tomographic images of interrogated targets. Criteria for discriminating materials by Z and discrimination power achieved by the technique for simple scenarios are discussed for different integration times. The simulation shows that Muon Tomography can clearly distinguish high-Z material from low-Z and medium-Z material. We have studied various systematic effects that affect the performance of the MT and the discrimination power. The implications of the simulation results for the planned development of a prototype MT station are discussed.
Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses the deflection of cosmic ray muons in matter to perform tomographic imaging of high-Z material inside a probed volume. A Muon Tomography Station (MTS) requires position-sensitive detectors with high spatial resolution for optimal tracking of incoming and outgoing cosmic ray muons. Micro Pattern Gaseous Detector (MPGD) technologies such as Gas Electron Multip…
Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles that contain high-Z material is a promising passive interrogation technique for solving this problem. We report on the design and construction of compact Micro-Pattern Gas Detectors for a small prototype MT station. This station will employ 10 tra…
Muon tomography is a relatively new method of radiography that utilizes muons from cosmic rays and their multiple Coulomb scattering property to distinguish materials. Researchers around the world have been developing various detection systems and image reconstruction algorithms for muon tomography applications, such as nuclear reactor monitoring and cargo inspection for contraband. This paper studies the principle in image reconstruction of muon tomography. Implementation and comparison of some popular algorithms with our simulation dataset will be presented as well as some ideas of future im…
Quality assurance and condition assessment of concrete structures is an important topic world-wide due to the ageing infrastructure and increasing traffic demands. Common topics include, but are not limited to, localisation of rebar or tendon ducts, geometrical irregularities, cracks, voids, honeycombing or other flaws. Non-destructive techniques such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in…
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research. Phase-contrast imaging extends the domain of application of X-ray micro tomography to classes of samples that exhibit weak attenuation, thus appear with poor contrast in standard X-ray imaging. Notable examples are low-atomic-number materials, like carbon-fibre composites, soft matter and biological soft tissues. We report on a compact and cost effective system for …
Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors with high spatial resolution should be particularly suited for tracking muons in an MT application, we propose to use compact micro-pattern gas detectors, such as Gas Electron Multipliers (GEMs), for muon tomography. We present a detailed GEANT4 simulation of a GEM-based MT station for various scenarios of threat material detection. Cosmic ray muon tracks cros…
Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could complement standard radiation detection portals currently deployed at international borders and ports, which are not very sensitive to heavily shielded nuclear materials. We image small targets in 3D using $2\times 2 \times 2 mm^3$ voxels with a minimal muon tomography station prototype that tracks muons with Gas Electron Multiplier (GEM) detectors read out in 2…
Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas detectors is proposed to optimize the imaging time and quality. The proposed system includes eight Micromegas detectors based on the thermal bonding technique and a scalable readout system. In addition, a multiplexing method based on position encoding is developed to reduce the number of electronics channels by order of magnitude. The spatial resolution of the pr…
Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural comp…
The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu is a good candidate for this application. Its small size (down to 1 mm2) and the high photo-detection efficiency in the blue spectral region allow the direct readout of a highly segmented scintillator matrix improving the spatial resolution of the machine. Furthermore, this photo-detector is insensitive to static magnetic fields up to 5 T, which makes it a …
Full Characterization of a Mock Nuclear Waste Barrel with Muon Tomography using Micromegas Detectors
CEA/Irfu, Université Paris-Saclay(法国原子能委员会/核研究与物理技术研究所,巴黎萨克雷大学);Centro de Astropartículas y Física de Altas Energías (CAPA), Universidad de Zaragoza(高能天体粒子中心,萨拉戈萨大学)
In this contribution, cylindrical samples consisting of monodisperse soft (rubber) and stiff (glass) particles are pre-stressed under uniaxial compression. Acoustic P-waves at ultrasound frequencies are superimposed into prepared samples with different soft-stiff volume fractions. Earlier investigations showed the importance of particles networks, i.e. force chains, in controlling the effective mechanical properties of particulate systems. Measured P-wave modulus showed a significant decline while more soft particles are added due to a change in microstructure. However, for small contents of s…