Proton computed tomography (CT) is similar to x-ray CT but relies on protons rather than photons to form an image. In its most common operation mode, the measured quantity is the amount of energy that a proton has lost while traversing the imaged object from which a relative stopping power map can be obtained via tomographic reconstruction. To this end, a calorimeter which measures the energy deposited by protons downstream of the scanned object has been studied or implemented as energy detector in several proton CT prototypes. An alternative method is to measure the proton's residual velocity and thus its kinetic energy via the time of flight (TOF) between at least two sensor planes. In this work, we study the precision, i.e. image noise, which can be expected from TOF proton CT systems. We rely on physics models on the one hand and statistical models of the relevant uncertainties on the other to derive closed form expressions for the noise in projection images. The TOF measurement error scales with the distance between the TOF sensor planes and is reported as velocity error in ps/m. We use variance reconstruction to obtain noise maps of a water cylinder phantom given the scanner characteristics and additionally reconstruct noise maps for a calorimeter-based proton CT system as reference. We find that TOF proton CT with 30 ps/m velocity error reaches similar image noise as a calorimeter-based proton CT system with 1% energy error (1 sigma error). A TOF proton CT system with a 50 ps/m velocity error produces slightly less noise than a 2% calorimeter system. Noise in a reconstructed TOF proton CT image is spatially inhomogeneous with a marked increase towards the object periphery. This systematic study of image noise in TOF proton CT can serve as a guide for future developments of this alternative solution for estimating the residual energy of protons after the scanned object.
Sensitivity of silicon-to-water dose conversion and Bragg-peak metrics to stopping-power datasets in proton dosimetry
Instituto de Pesquisas Energéticas e Nucleares(能源与核研究研究所);Departamento de Física, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia(穆尔西亚大学光学与纳米物理研究中心物理系);Departament de Física, Universitat d’Alacant(阿利坎特大学物理系);Instituto de Física da Universidade de São Paulo(圣保罗大学物理研究所);National Physical Laboratory(英国国家物理实验室)
K-shell Core Electron Excitations in the Electronic Stopping of Protons in Water
由于质子束在放射肿瘤学中的应用越来越广泛,对质子辐照下液态水中核心电子激发的作用有了详细的了解变得非常重要。利用基于实时含时密度泛函理论的第一性原理非平衡态模拟方法,我们确定了电子阻止本领,即从辐照离子到电子的能量转移速率随速度的变化。电子阻止本领曲线同意定量在整个速度范围内的实验数据是可用的。另外值得注意的是,我们观察到我们的第一性原理的结果和常用的微扰理论模型之间的显着差异。水分子氧核电子的激发是决定电子阻止本领曲线超过其最大值的关键因素。在8.0 a. u的高质子速度下,核心电子的贡献占阻止本领的三分之一。(1.6 MeV)。这些K-壳层芯电子激发不仅为能量传递提供了额外的通道,而且它们还显著地影响价电子激发。在激发过程中,产生的空穴仍然高度局限于照射质子路径周围几埃的范围内,而电子则被激发远离路径。尽管K壳层电子对电子阻止本领有很大贡献,但就激发密度而言,它所起的作用相当小:即使在8.0 a. u的高质子速度下,也只有1%的空穴群包含K壳层空穴。这里揭示的激发行为与X/γ射线光子辐射明显不同,X/γ射线光子辐射是放射肿瘤学中最常用的电离辐射类型。
Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom
Universität zu Lübeck(吕贝克大学);INFN sezione di Torino(都灵意大利国家核物理研究所);State University of Santa Cruz(圣克鲁斯州立大学);Fondazione CNAO(CNAO基金会);Università degli Studi di Torino(都灵大学)
Reconstruction of proton relative stopping power with a granular calorimeter detector model
University of Kaiserslautern-Landau(凯泽斯劳滕-兰道大学);University of Bergen(卑尔根大学);HUN-REN Wigner Research Centre for Physics(匈牙利研究与教育网络维格纳物理研究中心);Research and Production Enterprise ”LTU” (RPELTU)(LTU研究与生产企业);Institute for Subatomic Physics, Utrecht University/Nikhef(乌得勒支大学/尼赫夫亚原子物理研究所);St. Petersburg University(圣彼得堡大学);Western Norway University of Applied Sciences(西挪威应用科学大学)
Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interaction of proton and ion beams
Proposal of a consistent value for the mean excitation energy of liquid water using advanced modeling, detailed simulations and precission proton Bragg curves
Universidad de Murcia(穆尔西亚大学);Universitat d’Alacant(阿利坎特大学);Instituto de Pesquisas Energéticas e Nucleares(能源与核研究所)
Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan
Vinaver Medical(维纳弗医学);Faculty of Medicine, University of Novi Sad(诺维萨德大学医学院);Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University(杜克大学卡尔·E·拉文先进成像实验室与虚拟成像试验中心);Centro Nazionale di Adroterapia Oncologica (CNAO)(国家肿瘤质子治疗中心);Department of Radiology, Duke University(杜克大学放射系)
Optimal particle type and projection number in multi-modality relative stopping power acquisition
质子射线照相术结合X射线计算机断层成像(CT)已被提出,以获得患者特异性校准曲线,并减少带电粒子治疗癌症的范围不确定性。本研究的主要目的是确定最佳的带电粒子产生的射线照相,并确定最佳数量的必要的投影,以获得最小的范围误差。三种带电粒子被认为是产生射线照相:质子(p-rad),氦离子(α-rad)和碳离子(c-rad)。问题公式被视为最小二乘优化,argmin_x(||Ax-b||_2^2),其中投影矩阵A表示每种材料中每种粒子穿过的累积路径,b是表示为穿过的水等效厚度(WET)的带电粒子列表模式射线照相术,X是待优化的相对阻止本领(RSP)图。使用Geant 4 Monte Carlo(MC)工具包和拟人成人头部模型模拟带电粒子射线照相。A是通过使用凸包检测结合三次样条路径计算通过X射线CT的颗粒轨迹来确定的。对于所有颗粒类型,评估使用多个投影的影响(从1到6个投影)。在这项研究中,组织分割方法也进行了研究,可达到的精度。最好的结果(平均RSP误差低于0.7%,范围误差低于1毫米),获得了a-rad时,使用3个投影。单次α-rad照射体模的剂量为8 \muGy,低于X线摄影剂量。