LCLS-II-HE验证低温恒温器高梯度性能和失超行为
LCLS-II-HE verification cryomodule high gradient performance and quench behavior
摘要:
一个8腔,1.3 GHz,LCLS-II-HE低温振荡器在费米实验室组装和测试,以验证生产开始前的性能。其腔体进行了一种新的氮掺杂处理,以提高梯度性能。用修改的方案测试冷冻模块以处理零星猝灭,这在LCLS-II生产冷冻模块中观察到,并且归因于多重碰撞。专门的垂直测试实验支持归因于二次碰撞。验证低温恒温器在连续波模式下实现了200 MV的加速电压,对应于24.1 MV/m的平均加速梯度,显著超过173 MV的质量标准。平均Q 0(3.0x10^10)也超出其质量标准(2.7x10^10)。在处理之后,没有观察到场发射直到每个腔的最大梯度。本文回顾了低温性能,并讨论了几个月的计划中实施的操作问题和缓解措施。
英文摘要:
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。