arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2109.11312physics.med-ph
收藏

基于快速遗传算法(GA)的低场便携式MRI高性能永磁体阵列优化设计

High-Performance Permanent Magnet Array Design by a Fast Genetic Algorithm (GA)-based Optimization for Low-Field Portable MRI

Ting-Ou Liang, Yan Hao Koh, Tie Qiu, Erping Li, Wenwei Yu, Shao Ying Huang

摘要:

永磁体阵列(PMA)是用于身体部分专用低场(<0.5 T)便携式磁共振成像(MRI)的优选磁场源,因为其具有小的占地面积、无功耗并且不需要冷却系统。当前流行的PMA受到低于100 mT的横向场的限制,其中为长孔MRI系统开发的先进技术(例如,多通道技术)不能被应用。本文针对便携式头部成像,提出了一种基于内外环对和使用现成磁体块的稀疏高性能PMA。通过基于快速遗传算法(GA)的优化,所提出的PMA具有平均场强为111.40 mT的纵向磁场和不均匀性为10.57 mT(射频带宽<10%)的单调场模式,在直径为20 cm,长度为4.5 cm的视场(FoV)内。使用解析计算和数值模拟验证了所产生的场。通过检查模拟重建图像的质量来检查所设计的PMA的编码能力。所提出的字段优于线性模式的编码。PMA宽57.91 cm,长38 cm,具有87 x87 x104 cm ^3的5高斯范围,允许在小空间中进行操作。它重126.08公斤,包括一个提供强均匀场的固定主阵列和一个提供信号编码单调场的轻可旋转子梯度阵列(5.12公斤)。它的磁场产生效率为0.88 mT/kg,是提供单调场模式的稀疏PMA中最高的。计算每个磁体所经受的力以验证物理实现的可行性。所提出的PMA是一种有前途的替代方案,可为专用便携式MRI提供主磁场和梯度磁场。

英文摘要:

A permanent magnet array (PMA) is a preferred source of magnetic field for body-part-dedicated low-field (<0.5 T) portable magnetic resonance imaging (MRI) because it has a small footprint, no power consumption, and no need for a cooling system. The current popular PMA is limited by the transversal field below 100 mT, where advanced technologies developed for the long-bore MRI systems (e.g., multi-channel techniques) cannot be applied. In this paper, a sparse high-performance PMA is proposed based on inward-outward ring pairs and using magnet blocks that can be bought off the shelf, targeting on portable head imaging. Through a fast genetic algorithm (GA)-based optimization, the proposed PMA has a longitudinal magnetic field with an average field strength of 111.40 mT and a monotonic field pattern with inhomogeneity of 10.57 mT (an RF bandwidth of <10%) within a Field of View (FoV) of 20 cm in diameter and 4.5 cm in length. The resulting field was validated using analytic calculations and numerical simulations. The encoding capability of the designed PMA was examined by checking the quality of the simulated reconstructed images. The proposed field outperforms a linear pattern for encoding. The PMA is 57.91 cm wide, 38 cm long, has a 5-gauss range of 87x87x104 cm^3, allowing an operation in a small space. It weights 126.08kg, comprising of a stationary main array that supplies a strong homogeneous field, and a light rotatable sub-gradient-array (5.12kg) that supplies a monotonic field for signal encoding. It has a magnetic field generation efficiency of 0.88mT/kg, the highest among sparse PMAs that offer a monotonic field pattern. The force experienced by each magnet was calculated to validate the feasibility of physical implementation. The proposed PMA can be a promising alternative to supply the main and gradient fields combined for dedicated portable MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑