A permanent magnet array (PMA) is a preferred source of magnetic field for body-part-dedicated low-field (<0.5 T) portable magnetic resonance imaging (MRI) because it has a small footprint, no power consumption, and no need for a cooling system. The current popular PMA is limited by the transversal field below 100 mT, where advanced technologies developed for the long-bore MRI systems (e.g., multi-channel techniques) cannot be applied. In this paper, a sparse high-performance PMA is proposed based on inward-outward ring pairs and using magnet blocks that can be bought off the shelf, targeting on portable head imaging. Through a fast genetic algorithm (GA)-based optimization, the proposed PMA has a longitudinal magnetic field with an average field strength of 111.40 mT and a monotonic field pattern with inhomogeneity of 10.57 mT (an RF bandwidth of <10%) within a Field of View (FoV) of 20 cm in diameter and 4.5 cm in length. The resulting field was validated using analytic calculations and numerical simulations. The encoding capability of the designed PMA was examined by checking the quality of the simulated reconstructed images. The proposed field outperforms a linear pattern for encoding. The PMA is 57.91 cm wide, 38 cm long, has a 5-gauss range of 87x87x104 cm^3, allowing an operation in a small space. It weights 126.08kg, comprising of a stationary main array that supplies a strong homogeneous field, and a light rotatable sub-gradient-array (5.12kg) that supplies a monotonic field for signal encoding. It has a magnetic field generation efficiency of 0.88mT/kg, the highest among sparse PMAs that offer a monotonic field pattern. The force experienced by each magnet was calculated to validate the feasibility of physical implementation. The proposed PMA can be a promising alternative to supply the main and gradient fields combined for dedicated portable MRI.
Portable surrogate-free 4D MRI from standard fast multi-slice 2D MRI via implicit neural representations
Paul Scherrer Institut(保罗谢尔研究所);ETH Zurich(苏黎世联邦理工学院);University Hospital Basel(巴塞尔大学医院);University of Basel(巴塞尔大学);Institute for Biomedical Engineering, University and ETH Zurich(苏黎世大学与苏黎世联邦理工学院生物医学工程研究所)
A Reference System for Open Source Portable Low-Field MRI
Physikalisch-Technische Bundesanstalt (PTB) Braunschweig and Berlin(德国联邦物理技术研究院);Berlin Center for Advanced Neuroimaging, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health(柏林高级神经影像中心,夏里特医院—柏林大学医学院(柏林自由大学、柏林洪堡大学和柏林健康研究所的联合成员));Instituto Nazionale di Ricerca Metrologica (INRiM)(意大利国家计量研究所);Institute of Biomedical Imaging, Graz University of Technology(格拉茨工业大学生物医学成像研究所);Department of Biomedical Engineering, Eindhoven University of Technology(埃因霍温理工大学生物医学工程系);Division of Medical Physics, Department of Radiology, Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg(弗莱堡大学医学院医学中心放射科医学物理分部)
Qualitative and quantitative hard-tissue MRI with portable Halbach scanners
MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV)(分子成像与仪器研究所 (i3M),西班牙国家研究理事会 (CSIC) 和瓦伦西亚理工大学 (UPV));Full Body Insight S.L.;PhysioMRI Tech S.L.
Design and performance of a Toroidal RF Volume Coil with Intrinsic Electromagnetic Interference Rejection for low-field Portable Halbach-Based MRI Systems
Eindhoven University of Technology(埃因霍温理工大学);Leiden University Medical Center(莱顿大学医学中心)
A Portable Brain MRI Scanner for Underserved Settings and Point-Of-Care Imaging
Athinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital(阿西努拉·A·马丁诺斯生物医学成像中心放射科麻省总医院);Harvard Medical School(哈佛医学院);Dept. of Electrical Engineering, Massachusetts Institute of Technology(麻省理工学院电气工程系);Dept. of Physics, Harvard University(哈佛大学物理系);Dept. of Radiology, Massachusetts General Hospital(麻省总医院放射科);Harvard-MIT Division of Health Sciences and Technology(哈佛-麻省理工健康科学与技术学部)
A Review of Electromagnetic Elimination Methods for low-field portable MRI scanner
Harvard Medical School(哈佛医学院);University of Michigan(密歇根大学);Harvard University(哈佛大学);New York University(纽约大学);Columbia University(哥伦比亚大学);Guangxi University(广西大学)
A novel strategy for achieving a low-field lightweight permanent MRI magnet system with good magnetic field homogeneity and low eddy current
Institute of Condensed Matter and Material Physics, School of Physics, Peking University(北京大学物理学院凝聚态物质与材料物理研究所);NingBo ChuanShanjia Electrical and Mechanical CO., LTD(宁波传山佳机电有限公司);Division of Functional Materials, Central Iron & Steel Research Institute(中央钢铁研究院功能材料部);Hefei Gangyan Rare Earth Permanent Magnetic Materials Research Institute Co., Ltd(合肥钢研稀土永磁材料研究所有限公司);State Key Laboratory of Rare Earth Permanent Magnetic Materials(稀土永磁材料国家重点实验室);Beijing Ri-Bei Technology Co., Ltd.(北京日北科技有限公司);Beijing MagnVue Medix Co., Ltd.(北京磁维医疗科技有限公司)
Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院);Berlin Center for Advanced Neuroimaging, Charite–Universitatsmedizin Berlin, Corporate Member of Freie Universitat Berlin, Berlin Institute of Health(柏林高级神经成像中心,柏林夏里特医科大学,柏林自由大学企业成员,柏林健康研究所);Just Transition Center, Group C1, Martin-Luther-Universität Halle-Wittenberg(公正转型中心C1组,哈勒-维滕贝格马丁路德大学);Open Source Imaging Initiative (OSI²) e.V.(开源影像倡议协会);Helmut Schmidt University(赫尔穆特·施密特大学)
Chandra Family Department of Electrical and Computer Engineering The University of Texas at Austin(电气与计算机工程系Chandra家族部门德克萨斯大学奥斯汀分校);Department of Imaging Physics MD Anderson Cancer Center(成像物理系MD安德森癌症中心);Department of Diagnostic Medicine The University of Texas at Austin Dell Medical School(诊断医学系德克萨斯大学奥斯汀分校Dell医学院);Oden Institute for Computational Engineering and Sciences The University of Texas at Austin(计算工程与科学学院Oden研究所德克萨斯大学奥斯汀分校)
Birth of the Coil: another Milestone towards a fully reproducible low-field MRI scanner for head-imaging
Istituto Nazionale di Ricerca Metrologica (INRiM)(意大利国家计量研究所);Institute of Biomedical Imaging, Graz University of Technology(格拉茨工业大学生物医学成像研究所);Physikalisch-Technische Bundesanstalt (PTB) Braunschweig and Berlin(德国联邦物理技术研究院);Universidad Comunera(科穆内拉大学);University of Alberta(阿尔伯塔大学);Cross Cancer Institute(交叉癌症研究所)
A fully open-source framework for streaming and cloud-processing of low-field MRI data
Institute for Molecular Imaging and Instrumentation (i3M), Consejo Superior de Investigaciones Científicas (CSIC) & Universitat Politècnica de València (UPV)(分子成像与仪器研究所,西班牙国家研究委员会及巴伦西亚理工大学);Microsoft Research, Health Futures(微软研究院健康未来部门);Full Body Insight. S.L.(全身体洞察有限公司);PhysioMRI Tech. S.L.(物理磁共振技术有限公司);Leiden University Medical Center (LUMC)(莱顿大学医学中心);Yale University(耶鲁大学)
A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systems
The Institute for Instrumentation in Molecular Imaging (I3M), CSIC–Universitat Politècnica de València(分子成像仪器研究所(I3M),西班牙瓦伦西亚理工大学);C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center(莱顿大学医学中心放射科 C.J. Gorter 磁共振中心);PhysioMRI Tech