arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2109.00760physics.acc-ph
收藏

储存环的注入反馈

Injection Feedback for a Storage Ring

A. Moutardier, N. Delerue, C. Bruni, I. Chaikovska, S. Chancé, E. E. Ergenlik, V. Kubytskyi, H. Monard

摘要:

我们报告了ThomX存储环项目的注入反馈方案。X-ray X是一个50 MeV的电子加速器原型,它将在储存环中使用康普顿背散射来产生高通量的硬X射线。考虑到慢束阻尼(在环中),注入必须以高精度执行,以避免大的电子感应加速器振荡。一个自制的分析代码是用来计算的校正,需要施加之前的束注入,以实现几百微米的束位置精度在第一束位置监测器(BPM)。为此,代码需要环诊断装置提供的信息。迭代反馈系统已使用MadX模拟进行了测试。我们的模拟表明,在所有情况下,可以在不到50次迭代中实现与BPM的准确性相匹配的性能。这种反馈算法的细节,其效率和模拟进行了讨论。

英文摘要:

We report on an injection feedback scheme for the ThomX storage ring project. ThomX is a 50-MeV-electron accelerator prototype which will use Compton backscattering in a storage ring to generate a high flux of hard X-rays. Given the slow beam damping (in the ring), the injection must be performed with high accuracy to avoid large betatron oscillations. A homemade analytic code is used to compute the corrections that need to be applied before the beam injection to achieve a beam position accuracy of a few hundred micrometers in the first beam position monitors (BPMs). In order to do so the code needs the information provided by the ring's diagnostic devices. The iterative feedback system has been tested using MadX simulations. Our simulations show that a performance that matches the BPMs' accuracy can be achieved in less than 50 iterations in all cases. Details of this feedback algorithm, its efficiency and the simulations are discussed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑