Design and implementation of an islanded hybrid microgrid system for a large resort center for Penang Island with the proper application of excess energy
RMIT University(皇家墨尔本理工大学)
SK. A. Shezan, S. Rawdah, Shafin Ali, Ziaur Rahman
由于文明的国际化和发展,能源需求每天都在加速增长。然而,适当经济地利用孤岛混合微电网系统(IHMS)产生的未被负载消耗的额外能量是一项重大的全球挑战。为了解决上述传票,本研究的重点是多个最佳组合的综合健康管理系统的槟榔屿山度假村位于槟榔屿,马来西亚,有效地利用多余的能源。为了有效地利用这些多余的能量,电加热器以及存储罐已被设计为具有适当的能量管理的分流负载。此外,系统设计采用HOMER Pro软件进行了有益的实用分析。此外,MATLAB Simulink通过表示2068和19,072 kW的值来稳定整个系统,这些值已被确定为度假村每天的近似峰值和平均负载。此外,优化的IHMS包括光伏(PV)电池、柴油发电机、风力涡轮机、蓄电池和转换器。与此相邻,优化的系统随后具有$21.66 million, Renewable Fraction (RF) of 27.8%, Cost of Energy (COE) of $ 0.165/kWh的净现值成本(NPC)、1,735,836 kg/年的CO2和每年517.29 MWh的过剩能量。由于柴油发电机引线系统被包括在该方案中,因此实现了$0.217/kWh, CO2 of 5,124,879 kg/year, and NPC of $ 2 325万的COE。电加热器作为分流负载有效地利用了多余的能量。
英文摘要:
The energy demand is growing daily at an accelerated pace due to the internationalization and development of civilization. Yet proper economic utilization of additional energy generated by the Islanded Hybrid Microgrid System (IHMS) that was not consumed by the load is a major global challenge. To resolve the above-stated summons, this research focuses on a multi-optimal combination of IHMS for the Penang Hill Resort located on Penang Island, Malaysia, with effective use of redundant energy. To avail this excess energy efficiently, an electrical heater along with a storage tank has been designed concerning diversion load having proper energy management. Furthermore, the system design has adopted the HOMER Pro software for profitable and practical analysis. Alongside, MATLAB Simulink had stabilized the whole system by representing the values of 2068 and 19,072 kW that have been determined as the approximated peak and average load per day for the resort. Moreover, the optimized IHMS is comprehended of Photovoltaic (PV) cells, Diesel Generator, Wind Turbine, Battery, and Converter. Adjacent to this, the optimized system ensued in having a Net Present Cost (NPC) of $21.66 million, Renewable Fraction (RF) of 27.8%, Cost of Energy (COE) of $0.165/kWh, CO2 of 1,735,836 kg/year, and excess energy of 517.29MWh per annum. Since the diesel generator lead system was included in the scheme, a COE of $0.217/kWh, CO2 of 5,124,879 kg/year, and NPC of $23.25 million were attained. The amount of excess energy is effectively utilized with an electrical heater as a diversion load.
A decentralized scalable approach to voltage control of DC islanded microgrids
Università degli Studi di Pavia(帕维亚大学);United Technologies Research Center Ireland(联合技术研究中心爱尔兰);Institute of Energy Technology, Aalborg University(奥尔堡大学能源技术研究所)
Upside Risk Effect on Reliability of Microgrids Considering Demand Response Program and COVID-19: An Investigation on Health System and Power System Interactions
Plug-and-play and coordinated control for bus-connected AC islanded microgrids
United Technologies Research Center Ireland(联合技术研究院爱尔兰);Dipartimento di Ingegneria Industriale e dell’Informazione, Università degli Studi di Pavia(帕维亚大学工业与信息技术系);Institute of Energy Technology, Aalborg University(奥尔堡大学能源技术研究所);Automatic Control Laboratory, École Polytechnique Fédérale de Lausanne (EPFL)(洛桑联邦理工学院自动控制实验室)
A Distributed Scalable Architecture using L1 Adaptive Controllers for Primary Voltage Control of DC Microgrids
University College Cork(科克大学);United Technologies Research Centre Ireland Ltd(联合技术研究院爱尔兰有限公司);MaREI-SFI Research Centre, University College Cork(科克大学马雷伊-科学基金会研究中心)
A Communication-Free Master-Slave Microgrid with Power Sharing
Johann Bernoulli Institute for Mathematics and Computer Science, University of Groningen(格罗宁根大学约翰·伯努利数学与计算机科学研究所);Engineering and Technology Institute, University of Groningen(格罗宁根大学工程与技术研究所)
Improving Power Quality and Power Sharing in Unbalanced Multi-Microgrids Using Energy Storage System
单相分布式电源(DG)和不平衡负荷向三相DG的集成给微网(MG)的运行系统带来了挑战。这些挑战包括在MG的公共耦合点(PCC)处的不平衡电压和不相等的功率流。针对由单台和三台光伏分布式发电组成的孤岛多微网,提出了一种具有多功能控制的储能系统,以提高微网的电能质量和微网间的功率共享。建议的多功能控制包括一个无功功率补偿(RPC),PCC功率平衡调节器(PBR),和无功功率共享算法(RPSA)。RPC和PBR改善了MMG的三相PCC电压和功率不平衡,RPSA调节MMG之间的无功功率分配。该策略在Opal-RT OP 5600实时仿真器上进行了实验验证。PCC处的电压不平衡系数(VUF)从4.3%降低到0.03%,而三相和单相无功功率在不同额定DG之间按比例分配。
Resilient Hierarchical Power Control for Hybrid GFL/GFM Microgrids Under Mixed Cyber-Attacks and Physical Constraints
State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University(浙江大学控制科学与工程学院工业控制技术国家重点实验室);College of Control Science and Engineering, Zhejiang University(浙江大学控制科学与工程学院);Huzhou Industrial Control Technology Research Institute(湖州工业控制技术研究院);Zhejiang Key Laboratory of Decision Intelligence(浙江省决策智能重点实验室);Research Institute of China Southern Power Grid Co., Ltd.(中国南方电网有限责任公司电网科学研究院)