The need to restore and keep the grid running or fast restoration during emergencies such as extreme weather conditions is quite apparent given the reliance of other infrastructure on electricity. One promising approach to electricity restoration is the use of locally available energy resources to restore the system to form isolated microgrids. In this paper, we present a black start restoration method that forms islanded microgrids after a blackout. The master DGs in the formed microgrids are coordinated to work together through droop control. Several constraints, including incentive-based demand response (DR) with direct load control (DLC) and distributed generator (DG) operation constraints, were formulated and linearized to realize a mixed-integer linear programming (MILP) restoration model. To improve compactness and to ensure that the model is neither under-sized nor over-sized, a pre-processing graph analysis approach was introduced which helps to characterize the least number of restoration steps needed to optimally restore the microgrid. Studies were performed on a modified IEEE 123 node test feeder to evaluate the effects of demand response, non-dispatchable DGs, and choice of restoration steps on the quality of the restoration solution.
This paper addresses the problem of distributed secondary voltage control of an islanded microgrid (MG) from a cyber-physical perspective. An event-triggered distributed model predictive control (DMPC) scheme is designed to regulate the voltage magnitude of each distributed generators (DGs) in order to achieve a better trade-off between the control performance and communication and computation burdens. By using two novel event triggering conditions that can be easily embedded into the DMPC for the application of MG control, the computation and communication burdens are significantly reduced wi…
This paper proposes a distributed secondary voltage control method based on extended state Kalman-Bucy filter (ESKBF) and fast terminal sliding mode (FTSM) control for the resilient operation of an islanded microgrid (MG) with inverter-based distributed generations (DGs). To tackle the co-existence of multiple uncertainties, a unified modelling framework is proposed to represent the set of different types of disturbances, including parameter perturbation, measurement noise, and immeasurably external variables, by an extended state method. Kalman-Bucy filter is then applied to accurately estima…
This paper proposes a new distributed consensus-based control method for voltage and frequency control of fully inverter-based islanded microgrids (MGs). The proposed method includes the active power sharing in voltage control to improve the reactive power sharing accuracy and thus generalizes some existing secondary frequency and voltage control methods. Firstly, frequency is regulated by distributed secondary frequency control. Secondly, voltage is regulated by distributed average voltage control and decentralized individual voltage control. It offers a tunable trade-off between voltage regu…
Voltage and frequency control in an islanded AC microgrid (ImGs) amount to stabilizing an a priori unknown ImG equilibrium induced by loads and changes in topology. This paper puts forth a unified control framework which, while guaranteeing such stability, allows for modular ImGs interconnecting multiple subsystems, that is, dynamic RLC lines, nonlinear constant impedance, current, power (ZIP) and exponential (EXP) loads, and inverter-based distributed generation units (DGUs) controlled with different types of primary controllers. The underlying idea of the framework is based one equilibrium-i…
Hierarchical architectures stacking primary, secondary, and tertiary layers are widely employed for the operation and control of islanded DC microgrids (DCmGs), composed of Distribution Generation Units (DGUs), loads, and power lines. However, a comprehensive analysis of all the layers put together is often missing. In this work, we remedy this limitation by setting out a top-to-bottom hierarchical control architecture. Decentralized voltage controllers attached to DGUs form our primary layer. Governed by an MPC--based Energy Management System (EMS), our tertiary layer generates optimal power …
Unbalanced and nonlinear loads connected to microgrids (MG) with local distributed energy resources (DERs) are two of the leading causes of power quality problems. Nonlinearloads introduce voltage and current harmonics, and single-phase loads can cause voltage and current imbalances in a three-phase network. This paper presents a hierarchical control scheme for voltage-controlled photovoltaic (PV) inverters with unbalanced and nonlinear loads in micro-grids. The hierarchical control consists of primary control and voltage compensation control(VCC) and a DC voltage regulator (VR). The primary c…
A decentralized scalable approach to voltage control of DC islanded microgrids
Università degli Studi di Pavia(帕维亚大学);United Technologies Research Center Ireland(联合技术研究中心爱尔兰);Institute of Energy Technology, Aalborg University(奥尔堡大学能源技术研究所)
COVID-19 has a vast impact on the power systems considering the customers demand and human resources. During this situation, the utilization of microgrids (MGs) may help the power systems balance the generation and consumption of power, which leads to customer satisfaction. In this paper, the optimal power scheduling of energy sources in an islanded MG by considering the upside risk (UR) is proposed for the very first time. The intended islanded MG consists of various sources such as wind turbine (WT), photovoltaic (PV), diesel generator (DGR), and battery. The goals of this work are minimizin…
Plug-and-play and coordinated control for bus-connected AC islanded microgrids
United Technologies Research Center Ireland(联合技术研究院爱尔兰);Dipartimento di Ingegneria Industriale e dell’Informazione, Università degli Studi di Pavia(帕维亚大学工业与信息技术系);Institute of Energy Technology, Aalborg University(奥尔堡大学能源技术研究所);Automatic Control Laboratory, École Polytechnique Fédérale de Lausanne (EPFL)(洛桑联邦理工学院自动控制实验室)
A Distributed Scalable Architecture using L1 Adaptive Controllers for Primary Voltage Control of DC Microgrids
University College Cork(科克大学);United Technologies Research Centre Ireland Ltd(联合技术研究院爱尔兰有限公司);MaREI-SFI Research Centre, University College Cork(科克大学马雷伊-科学基金会研究中心)
In this paper, we propose a minimax model predictive control (MPC)-based energy management system that is robust with respect to uncertainties in renewable infeed and load. The MPC formulation includes a model of low-level droop control with saturation at the power and energy limits of the units. Robust MPC-based energy management systems tend to under-utilize the renewable energy sources to guarantee safe operation. In order to mitigate this effect, we further consider droop control of renewable energy sources. For a microgrid with droop-controlled units, we show that enhancing droop feedback…
The energy demand is growing daily at an accelerated pace due to the internationalization and development of civilization. Yet proper economic utilization of additional energy generated by the Islanded Hybrid Microgrid System (IHMS) that was not consumed by the load is a major global challenge. To resolve the above-stated summons, this research focuses on a multi-optimal combination of IHMS for the Penang Hill Resort located on Penang Island, Malaysia, with effective use of redundant energy. To avail this excess energy efficiently, an electrical heater along with a storage tank has been design…
Islanded microgrids powered by renewable energy require costly energy storage systems due to the uncontrollable generators. Energy storage needs are amplified when load and generation are misaligned on hourly, monthly, or seasonal timescales. Diversification of both loads and generation can smooth out such mismatches. The ideal type of battery to smooth out remaining generation deficits will depend on the duration(s) that energy is stored. This study presents a controls co-design approach to design an islanded microgrid, showing the benefit of hybridizing tidal and solar generation and hybridi…
In this paper, we introduce a distributed secondary frequency control scheme for an islanded ac microgrid under event-triggered communication. An integral type event-triggered mechanism is proposed by which each distributed generator (DG) asynchronously and periodically checks its triggering condition and determines whether to update its control inputs and broadcast its states to neighboring DGs. In contrast to existing event-triggered strategies on secondary control of microgrids, under the proposed sampled-data based event-triggered mechanism, DGs need not be synchronized to a common clock a…
Mobile energy storage systems (MESS) offer great operational flexibility to enhance the resiliency of distribution systems in an emergency condition. The optimal placement and sizing of those units are pivotal for quickly restoring the curtailed loads. In this paper, we propose a model for load restoration in a microgrid while concurrently optimizing the MESS routes required for the same. The model is formulated as a mixed integer second order cone program by considering the state of charge and evolution of the lower and upper bounds of battery capacities. Simulation results tested on the IEEE…
In case of high impact low probability events, in order to restore the critical loads of the distribution network as much as possible, it is necessary to employ all available resources such as microgrids and distributed generations. This paper presents a two-stage method for critical load restoration after an extreme event utilizing the coordination of all available distributed generations, microgrids, and demand response programs. In the first stage, the post-disaster reconfiguration of the network is determined, and in the second stage, the demand response outputs of the responsive loads and…
Distributed energy storage systems (ESSs) can be efficiently leveraged for load restoration (LR) for a microgrid (MG) in island mode. When the ESSs are owned by third parties rather than the MG operator (MGO), the ESS operating setpoints may be considered as private information of their respective owners. Therefore, efforts must be put forth to avoid the disclosure through adversarial analysis of load setpoints. In his paper, we consider a scenario where LR takes place in a MG by determining load and ESS power injections through the solution of an AC optimal power flow (AC-OPF) problem. Since …
The capability to switch between grid-connected and islanded modes has promoted adoption of microgrid technology for powering remote locations. Stabilizing frequency during the islanding event, however, is a challenging control task, particularly under high penetration of converter-interfaced sources. In this paper, a numerical optimal control (NOC)-based control synthesis methodology is proposed for preparedness of microgrid islanding that ensure guaranteed performance. The key feature of the proposed paradigm is near real-time centralized scheduling for real-time decentralized executing. For…
This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to…
In this study, we propose a decision-making strategy for pinning-based distributed multi-agent (PDMA) automatic generation control (AGC) in islanded microgrids against stochastic communication disruptions. The target microgrid is construed as a cyber-physical system, wherein the physical microgrid is modeled as an inverter-interfaced autonomous grid with detailed system dynamic formulation, and the communication network topology is regarded as a cyber-system independent of its physical connection. The primal goal of the proposed method is to decide the minimum number of generators to be pinned…