使用过滤相互作用顶点成像的重离子治疗中的分次内和分次间相对范围验证

Intra- and Inter-Fraction Relative Range Verification in Heavy-Ion Therapy Using Filtered Interaction Vertex Imaging

Devin Hymers, Eva Kasanda, Vinzenz Bildstein, Joelle Easter, Andrea Richard, Artemis Spyrou, Cornelia Höhr, Dennis Mücher

摘要:

重离子治疗,特别是使用扫描(有源)射束输送,提供了一个精确的和高度共形的剂量分布,最大剂量沉积为每个笔形射束在其端点(布拉格峰),和低的入口和出口剂量。为了充分利用这种精度,需要稳健的范围验证方法;这些方法确保布拉格峰在患者体内正确定位,并按规定输送剂量。相对范围验证允许布拉格峰间距的级分内监测以确保每个级分的完全覆盖,以及级分间监测以确保所有级分一致地输送。为了确认用于相对范围验证的拟议滤波相互作用顶点成像方法,使用${}^{16}$ O型光束在40 mm聚甲基丙烯酸甲酯体模中提供12个布拉格峰位置。使用位置敏感硅探测器监测在体模中产生的次级粒子。在这些探测器上记录的事件,以及治疗射束轴的测量值,用于重建这些次级粒子在体模中的起源部位。这些重建点的深度分布的远端边缘用逻辑拟合确定,并且使这些拟合之间的$χ^2$统计最小化所需的深度平移用于计算任何两个布拉格峰位置之间的范围移位。在所有情况下,距离偏移都以亚毫米精度确定,平均值的标准偏差为220(10)$μ$ m。该结果验证了过滤交互顶点成像作为可靠的相对范围验证方法,该方法应该能够监测扫描重离子治疗计划的每个部分中的每个能量步骤。

英文摘要:

Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose. To take full advantage of this precision, robust range verification methods are required; these methods ensure that the Bragg peak is positioned correctly in the patient and the dose is delivered as prescribed. Relative range verification allows intra-fraction monitoring of Bragg peak spacing to ensure full coverage with each fraction, as well as inter-fraction monitoring to ensure all fractions are delivered consistently. To validate the proposed filtered Interaction Vertex Imaging method for relative range verification, a ${}^{16}$O beam was used to deliver 12 Bragg peak positions in a 40 mm poly-(methyl methacrylate) phantom. Secondary particles produced in the phantom were monitored using position-sensitive silicon detectors. Events recorded on these detectors, along with a measurement of the treatment beam axis, were used to reconstruct the sites of origin of these secondary particles in the phantom. The distal edge of the depth distribution of these reconstructed points was determined with logistic fits, and the translation in depth required to minimize the $χ^2$ statistic between these fits was used to compute the range shift between any two Bragg peak positions. In all cases, the range shift was determined with sub-millimeter precision, to a standard deviation of the mean of 220(10) $μ$m. This result validates filtered Interaction Vertex Imaging as a reliable relative range verification method, which should be capable of monitoring each energy step in each fraction of a scanned heavy-ion treatment plan.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑