Coronary artery disease (CAD) remains the world's leading cause of mortality and the disease burden is continually expanding as the population ages. Recently, the MR-INFORM randomised trial has demonstrated that the management of patients with stable CAD can be guided by stress perfusion cardiovascular magnetic resonance (CMR) imaging and it is non-inferior to the using the invasive reference standard of fractional flow reserve. The benefits of using stress perfusion CMR include that it is non-invasive and significantly reduces the number of unnecessary coronary revascularisations. As compared to other ischaemia tests, it boasts a high spatial resolution and does not expose the patient to ionising radiation. However, the main limitation of stress perfusion CMR is that the diagnostic accuracy is highly dependent on the level of training of the operator, resulting in the test only being performed routinely in experienced tertiary centres. The clinical translation of stress perfusion CMR would be greatly aided by a fully automated, user-independent, quantitative evaluation of myocardial blood flow. This thesis presents major steps towards this goal: robust motion correction, automated image processing, reliable quantitative modelling, and thorough validation. The motion correction scheme makes use of data decomposition techniques, such as robust principal component analysis, to mitigate the difficulties in image registration caused by the dynamic contrast enhancement. The motion corrected image series are input to a processing pipeline which leverages the recent advances in image processing facilitated by deep learning. The pipeline utilises convolutional neural networks to perform a series of computer vision tasks including myocardial segmentation and right ventricular insertion point detection...
Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains as a research tool. Building upon the previously described imaging sequence, this paper presents algorithm and implementation of an automated solution for inline perfusion flow mapping with step by step performance characterization. An inline perfusion flow mapping workflow is proposed and demonstrated on normal volunteers. Initial evaluation demonstrates the fully automated proposed solution for the res…
Washington University in St. Louis(圣路易斯华盛顿大学);Mallinckrodt Institute of Radiology(马林克罗特放射学研究所)
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, studies have shown that these methods may have limited impact on the performance of clinical tasks in SPECT. To address this issue, we use concepts from the literature on model observers and our underst…
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Lea…
Eindhoven University of Technology(埃因霍温理工大学);King’s College London(伦敦国王学院);Philips Healthcare(飞利浦医疗)
Tracer-kinetic models allow for the quantification of kinetic parameters such as blood flow from dynamic contrast-enhanced magnetic resonance (MR) images. Fitting the observed data with multi-compartment exchange models is desirable, as they are physiologically plausible and resolve directly for blood flow and microvascular function. However, the reliability of model fitting is limited by the low signal-to-noise ratio, temporal resolution, and acquisition length. This may result in inaccurate parameter estimates. This study introduces physics-informed neural networks (PINNs) as a means to perf…
Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. …
King’s College London(伦敦国王学院);The Alan Turing Institute(艾伦·图灵研究所);Eindhoven University of Technology(埃因霍温理工大学);Philips Healthcare(飞利浦医疗)
The quantification of myocardial perfusion MRI has the potential to provide a fast, automated and user-independent assessment of myocardial ischaemia. However, due to the relatively high noise level and low temporal resolution of the acquired data and the complexity of the tracer-kinetic models, the model fitting can yield unreliable parameter estimates. A solution to this problem is the use of Bayesian inference which can incorporate prior knowledge and improve the reliability of the parameter estimation. This, however, uses Markov chain Monte Carlo sampling to approximate the posterior distr…
School of Biomedical Engineering and Imaging Sciences, King’s College London(伦敦国王学院生物医学工程与影像科学学院);The Alan Turing Institute(阿兰·图灵研究所);Philips Healthcare(飞利浦医疗保健);Eindhoven University of Technology(埃因霍温理工大学)
Purpose: Tracer-kinetic models can be used for the quantitative assessment of contrast-enhanced MRI data. However, the model-fitting can produce unreliable results due to the limited data acquired and the high noise levels. Such problems are especially prevalent in myocardial perfusion MRI leading to the compromise of constrained numerical deconvolutions and segmental signal averaging being commonly used as alternatives to the more complex tracer-kinetic models. Methods: In this work, the use of hierarchical Bayesian inference for the parameter estimation is explored. It is shown that with Bay…
Objective: In this work, we set out to investigate the accuracy of direct attenuation correction (AC) in the image domain for the myocardial perfusion SPECT imaging (MPI-SPECT) using two residual (ResNet) and UNet deep convolutional neural networks. Methods: The MPI-SPECT 99mTc-sestamibi images of 99 participants were retrospectively examined. UNet and ResNet networks were trained using SPECT non-attenuation corrected images as input and CT-based attenuation corrected SPECT images (CT-AC) as reference. The Chang AC approach, considering a uniform attenuation coefficient within the body contour…
National Heart, Lung and Blood Institute, National Institutes of Health(美国国立卫生研究院国家心肺血液研究所);Barts Health NHS Trust(巴特保健国民保健信托基金);University of Leeds(利兹大学);Royal Free Hospital(皇家自由医院)
Recent development of quantitative myocardial blood flow (MBF) mapping allows direct evaluation of absolute myocardial perfusion, by computing pixel-wise flow maps. Clinical studies suggest quantitative evaluation would be more desirable for objectivity and efficiency. Objective assessment can be further facilitated by segmenting the myocardium and automatically generating reports following the AHA model. This will free user interaction for analysis and lead to a 'one-click' solution to improve workflow. This paper proposes a deep neural network based computational workflow for inline myocardi…
Compute-Optimal Network Design for Echocardiography Myocardial Segmentation and Perfusion Quantification using Neural Scaling Laws
Department of Bioengineering, Imperial College London(生物工程系,帝国理工学院伦敦分校);National Heart and Lung Institute, Imperial College London(国家心脏和肺 institute,帝国理工学院伦敦分校);Guy’s and St. Thomas’ NHS Foundation Trust(圣泰莫斯国家健康服务信托基金)
Clinical SPECT-MPI images of 345 patients acquired from a dedicated cardiac SPECT in list-mode format were retrospectively employed to predict normal-dose images from low-dose data at the half, quarter, and one-eighth-dose levels. A generative adversarial network was implemented to predict non-gated normal-dose images in the projection space at the different reduced dose levels. Established metrics including the peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), and structural similarity index metrics (SSIM) in addition to Pearson correlation coefficient analysis and derived pa…
A new method incorporating deep learning with shape priors for left ventricular segmentation in myocardial perfusion SPECT images
Zhengzhou University of Light Industry(郑州轻工业大学);Michigan Technological University(密歇根理工大学);Xi'an University of Posts and Telecommunications(西安邮电大学);The First Affiliated Hospital of Nanjing Medical University(南京医科大学第一附属医院)
Motion free reconstruction of compressively sampled cardiac perfusion MR images is a challenging problem. It is due to the aliasing artifacts and the rapid contrast changes in the reconstructed perfusion images. In addition to the reconstruction limitations, many registration algorithms under perform in the presence of the rapid intensity changes. In this paper, we propose a novel motion correction method that reconstructs the motion free image series from the undersampled cardiac perfusion MR data. The motion correction method uses the novel robust principal component analysis based reconstru…
Improved Robustness for Deep Learning-based Segmentation of Multi-Center Myocardial Perfusion MRI Datasets Using Data Adaptive Uncertainty-guided Space-time Analysis
Indiana University School of Medicine(印第安纳大学医学院);Purdue University(普渡大学);University of Calgary(卡尔加里大学);Cedars-Sinai Medical Center(西达赛奈医疗中心);Duke University(杜克大学);The Ohio State University(俄亥俄州立大学);Weill Cornell Medical Center(威尔康奈尔医学中心);OhioHealth(俄亥俄健康)
FedDA-TSformer: Federated Domain Adaptation with Vision TimeSformer for Left Ventricle Segmentation on Gated Myocardial Perfusion SPECT Image
Kennesaw State University(肯尼索州立大学);Michigan Technological University(密歇根理工大学);Xiangya Hospital, Central South University(中南大学湘雅医院);Chang Bing Show Chwan Memorial Hospital(彰滨秀传纪念医院);The First Affiliated Hospital of Nanjing Medical University(南京医科大学第一附属医院);Health Research Institute, Michigan Technological University(密歇根理工大学健康研究所)
Spatial-temporal V-Net for automatic segmentation and quantification of right ventricles in gated myocardial perfusion SPECT images
Michigan Technological University(密歇根理工大学);Hai’an People’s Hospital(海安市人民医院);Rush Medical College(拉什医学院);Cook County Health(库克县医疗系统);The First Affiliated Hospital of Nanjing Medical University(南京医科大学第一附属医院);Xi’an University of Posts and Telecommunications(西安邮电大学)
University of Notre Dame(圣母大学);Boston Children’s Hospital, Harvard Medical School(哈佛医学院波士顿儿童医院);Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital(广东省人民医院广东省心血管病研究所);University of Pittsburgh(匹兹堡大学)
Automatic myocardial segmentation of contrast echocardiography has shown great potential in the quantification of myocardial perfusion parameters. Segmentation quality control is an important step to ensure the accuracy of segmentation results for quality research as well as its clinical application. Usually, the segmentation quality control happens after the data acquisition. At the data acquisition time, the operator could not know the quality of the segmentation results. On-the-fly segmentation quality control could help the operator to adjust the ultrasound probe or retake data if the qual…
Universidad de Valladolid(巴利亚多利德大学);King’s College London(伦敦国王学院);Instituto Superior Técnico, Universidade de Lisboa(里斯本大学高等技术学院);Centre for Marine Sciences - CCMAR(海洋科学中心(CCMAR))
First-pass perfusion cardiac magnetic resonance (FPP-CMR) is becoming an essential non-invasive imaging method for detecting deficits of myocardial blood flow, allowing the assessment of coronary heart disease. Nevertheless, acquisitions suffer from relatively low spatial resolution and limited heart coverage. Compressed sensing (CS) methods have been proposed to accelerate FPP-CMR and achieve higher spatial resolution. However, the long reconstruction times have limited the widespread clinical use of CS in FPP-CMR. Deep learning techniques based on supervised learning have emerged as alternat…
National Heart, Lung and Blood Institute(国家心肺血液研究所);National Institutes of Health(美国国立卫生研究院);Barts Heart Centre(巴特心脏中心);Royal Free Hospital(皇家自由医院);University of Leeds(利兹大学)
Quantification of myocardial perfusion has the potential to improve detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Since failure here invalidates quantification, high accuracy is required. For this purpose, this study presents a robust AIF detection method using the convolutional neural net (CNN) model. CNN models were trained by assembling 25,027 scans (N=12,984 patients) from three hospitals, seven scanners. A test set of 5,721 scans (N=2,805 patients) evalua…
University of Virginia(弗吉尼亚大学);University of Virginia Health System(弗吉尼亚大学卫生系统)
Automated identification of myocardial scar from late gadolinium enhancement cardiac magnetic resonance images (LGE-CMR) is limited by image noise and artifacts such as those related to motion and partial volume effect. This paper presents a novel joint deep learning (JDL) framework that improves such tasks by utilizing simultaneously learned myocardium segmentations to eliminate negative effects from non-region-of-interest areas. In contrast to previous approaches treating scar detection and myocardium segmentation as separate or parallel tasks, our proposed method introduces a message passin…
Center for Advanced Medical Computing and Analysis(高级医学计算与分析中心);Gordon Center for Medical Imaging(戈登医学成像中心);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
Dynamic computed tomography perfusion (CTP) imaging is a promising approach for acute ischemic stroke diagnosis and evaluation. Hemodynamic parametric maps of cerebral parenchyma are calculated from repeated CT scans of the first pass of iodinated contrast through the brain. It is necessary to reduce the dose of CTP for routine applications due to the high radiation exposure from the repeated scans, where image denoising is necessary to achieve a reliable diagnosis. In this paper, we proposed a self-supervised deep learning method for CTP denoising, which did not require any high-dose referenc…
TAI-GAN: A Temporally and Anatomically Informed Generative Adversarial Network for early-to-late frame conversion in dynamic cardiac PET inter-frame motion correction
Yale University(耶鲁大学);IBM Research(IBM研究院);Yale New Haven Hospital(耶鲁-纽黑文医院);Yale School of Medicine(耶鲁医学院)
Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One of the main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component, which is particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT, no timing information can be retrieved to locate the primary source photons. Monte Carlo methods allow an event-by-event simulation of the scattering kinematics, which can be incorporated into a model of the imaging system response. This approach was adopted since the late Nineties by s…
University of Leicester(莱斯特大学);NIHR Leicester Biomedical Research Centre(NIHR莱斯特生物医学研究中心);Glenfield Hospital(格伦菲尔德医院);Norwegian University of Science and Technology (NTNU)(挪威科技大学);Saint-Petersburg State Electrotechnical University(圣彼得堡国立电工大学)
A "heart attack" or myocardial infarction (MI), occurs when an artery supplying blood to the heart is abruptly occluded. The "gold standard" method for imaging MI is Cardiovascular Magnetic Resonance Imaging (MRI), with intravenously administered gadolinium-based contrast (late gadolinium enhancement). However, no "gold standard" fully automated method for the quantification of MI exists. In this work, we propose an end-to-end fully automatic system (MyI-Net) for the detection and quantification of MI in MRI images. This has the potential to reduce the uncertainty due to the technical variabil…
Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg(生物医学工程人工智能系,埃尔朗根-纽伦堡弗里德里希-亚历山大大学);Department of Biomedical Engineering, The Ohio State University(生物医学工程系,俄亥俄州立大学);Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG(研究与临床转化,磁共振,西门子医疗有限公司);Division of Cardiovascular Medicine, The Ohio State University(心血管医学系,俄亥俄州立大学)