Automatic quality control of brain T1-weighted magnetic resonance images for a clinical data warehouse

Inria(法国国家信息与自动化研究所);Sorbonne Université(索邦大学);Institut du Cerveau - Paris Brain Institute - ICM(巴黎大脑研究所);Inserm(法国国家健康与医学研究院);CNRS(法国国家科学研究中心);AP-HP, Hôpital de la Pitié Salpêtrière(巴黎公立医院集团,皮提耶-萨勒佩特里医院);AP-HP, WIND department(巴黎公立医院集团,WIND部门)

Simona Bottani, Ninon Burgos, Aurélien Maire, Adam Wild, Sebastian Ströer, Didier Dormont, Olivier Colliot

摘要:

到目前为止,许多关于机器学习(ML)用于计算机辅助诊断的研究大多局限于高质量的研究数据。临床数据仓库收集医院的常规检查,为在现实环境中训练和验证ML模型提供了很大的希望。然而,这种临床数据仓库的使用需要质量控制(QC)工具。专家的可视化QC非常耗时,并且无法扩展到大型数据集。在本文中,我们提出了一个卷积神经网络(CNN)的自动质量控制的三维T1加权脑MRI的大型异构临床数据仓库。为此,我们使用了大巴黎地区医院的数据仓库(巴黎医院援助[AP-HP])。具体而言,目的是:1)识别不属于适当T1加权脑部MRI的图像; 2)识别注射钆的采集; 3)对总体图像质量进行评级。我们使用了5000张图像进行训练和验证,并使用了一组单独的500张图像进行测试。为了训练/验证CNN,由两名经过训练的评分员根据我们专门设计用于数据仓库设置的可视化QC协议对数据进行注释。对于目标1和2,我们的方法实现了极好的准确性(平衡准确性和F1评分\textgreater 90\%),与人类评分员相似。对于目标3,性能良好,但大大低于人类评分员。尽管如此,自动方法准确地识别了(平衡准确度和F1评分\textgreater 80\%)通常需要排除的低质量图像。总的来说,我们的方法将是有用的利用医院数据仓库在医学图像计算。

英文摘要:

Many studies on machine learning (ML) for computer-aided diagnosis have so far been mostly restricted to high-quality research data. Clinical data warehouses, gathering routine examinations from hospitals, offer great promises for training and validation of ML models in a realistic setting. However, the use of such clinical data warehouses requires quality control (QC) tools. Visual QC by experts is time-consuming and does not scale to large datasets. In this paper, we propose a convolutional neural network (CNN) for the automatic QC of 3D T1-weighted brain MRI for a large heterogeneous clinical data warehouse. To that purpose, we used the data warehouse of the hospitals of the Greater Paris area (Assistance Publique-Hôpitaux de Paris [AP-HP]). Specifically, the objectives were: 1) to identify images which are not proper T1-weighted brain MRIs; 2) to identify acquisitions for which gadolinium was injected; 3) to rate the overall image quality. We used 5000 images for training and validation and a separate set of 500 images for testing. In order to train/validate the CNN, the data were annotated by two trained raters according to a visual QC protocol that we specifically designed for application in the setting of a data warehouse. For objectives 1 and 2, our approach achieved excellent accuracy (balanced accuracy and F1-score \textgreater 90\%), similar to the human raters. For objective 3, the performance was good but substantially lower than that of human raters. Nevertheless, the automatic approach accurately identified (balanced accuracy and F1-score \textgreater 80\%) low quality images, which would typically need to be excluded. Overall, our approach shall be useful for exploiting hospital data warehouses in medical image computing.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑