呼吸音的记录在呼吸音异常的诊断中具有显著的益处。诊断中使用的声音的持续时间影响诊断的速度。本研究分析了窗宽对呼吸音异常诊断的影响以及最有效的诊断记录时间。首先,将窗口大小应用于由正常和异常呼吸声组成的数据集中的每个声音,0.5秒和从1到20秒增加1秒。然后,利用Mel倒谱系数(MFCC)推断出用于特征提取的窗口大小,并利用留一法和k-近邻(KNN)算法计算每个窗口的性能。结果,确定数据是显著的,在2秒和10秒之间的记录中平均性能为92.06%。

英文摘要:

The recording of respiratory sounds was of significant benefit in the diagnosis of abnormalities in respiratory sounds. The duration of the sounds used in the diagnosis affects the speed of the diagnosis. In this study, the effect of window size on diagnosis of abnormalities in respiratory sounds and the most efficient recording time for diagnosis were analyzed. First, window size was applied to each sound in the data set consisting of normal and abnormal breathing sounds, 0.5 second and from 1 to 20 seconds Increased by 1 second. Then, the data applied to window size was inferred feature extraction with Mel Frequency Cepstral Coefficient (MFCC) and the performance of each window was calculated using the leave one-out classifier and the k-nearest neighbor (KNN) algorithm. As a result, it was determined that the data was significant with an average performance of 92.06% in the records between 2 and 10 seconds.