arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2011.13742astro-ph.HEastro-ph.GA
收藏

用LOFAR测量150 MHz时36毫秒脉冲的色散变化

Dispersion measure variability for 36 millisecond pulsars at 150MHz with LOFAR

J. Y. Donner, J. P. W. Verbiest, C. Tiburzi, S. Osłowski, J. Künsemöller, A. -S. Bak Nielsen, J. -M. Grießmeier, M. Serylak, M. Kramer, J. M. Anderson, O. Wuckn… 展开作者

J. Y. Donner, J. P. W. Verbiest, C. Tiburzi, S. Osłowski, J. Künsemöller, A. -S. Bak Nielsen, J. -M. Grießmeier, M. Serylak, M. Kramer, J. M. Anderson, O. Wucknitz, E. Keane, V. Kondratiev, C. Sobey, J. W. McKee, A. V. Bilous, R. P. Breton, M. Brüggen, B. Ciardi, M. Hoeft, J. van Leeuwen, C. Vocks

摘要:

来自等离子体星的无线电脉冲受到等离子体色散的影响,这导致了与频率相关的传播延迟。在脉冲星计时实验中,这种效应的幅度变化会导致额外的红噪声源,包括旨在探测纳赫兹引力波的脉冲星计时阵列。我们的目标是量化的时变色散,大大提高了精度和频谱的这些变化。我们使用脉冲星计时技术来获得高精度的色散测量(DM)时间序列。我们的数据集由36毫秒的射电星的观测数据组成,这些射电星用LOFAR望远镜在~150 MHz的中心频率下观测了长达7.1年。这些来源中有17个是以每周的节奏观察的,而其余的则是以每月的节奏观察的。对于我们的大部分源,我们实现了10^-5 cm^-3 pc量级的中值DM精度。我们在所有样本中检测到DM的显著变化,DM不确定度的中位数小于2 × 10 ^-4 cm^-3 pc。在较高频率下的脉冲星定时实验的噪声贡献计算为0.1-10 us的水平在1.4 GHz的几年的时间跨度,这是在许多情况下大于1 us或更好的PTAs的目标的典型定时精度。我们没有发现任何证据表明DM依赖于我们样本中任何来源的射频。我们使用LOFAR获得的DM时间序列原则上可用于校正色散延迟变化的高频数据。然而,目前存在的实际限制是,由于频谱特性,多普勒雷达倾向于提供在1.4 GHz处的高精度到达时间(ToA)或在低频处的高DM精度,而不是两者。将高频ToA与LOFAR的ToA相结合来测量无限频率ToA和DM将改善结果。

英文摘要:

Radio pulses from pulsars are affected by plasma dispersion, which results in a frequency-dependent propagation delay. Variations in the magnitude of this effect lead to an additional source of red noise in pulsar timing experiments, including pulsar timing arrays that aim to detect nanohertz gravitational waves. We aim to quantify the time-variable dispersion with much improved precision and characterise the spectrum of these variations. We use the pulsar timing technique to obtain highly precise dispersion measure (DM) time series. Our dataset consists of observations of 36 millisecond pulsars, which were observed for up to 7.1 years with the LOFAR telescope at a centre frequency of ~150 MHz. Seventeen of these sources were observed with a weekly cadence, while the rest were observed at monthly cadence. We achieve a median DM precision of the order of 10^-5 cm^-3 pc for a significant fraction of our sources. We detect significant variations of the DM in all pulsars with a median DM uncertainty of less than 2x10^-4 cm^-3 pc. The noise contribution to pulsar timing experiments at higher frequencies is calculated to be at a level of 0.1-10 us at 1.4 GHz over a timespan of a few years, which is in many cases larger than the typical timing precision of 1 us or better that PTAs aim for. We found no evidence for a dependence of DM on radio frequency for any of the sources in our sample. The DM time series we obtained using LOFAR could in principle be used to correct higher-frequency data for the variations of the dispersive delay. However, there is currently the practical restriction that pulsars tend to provide either highly precise times of arrival (ToAs) at 1.4 GHz or a high DM precision at low frequencies, but not both, due to spectral properties. Combining the higher-frequency ToAs with those from LOFAR to measure the infinite-frequency ToA and DM would improve the result.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑