arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2010.03395physics.ins-det
收藏

多环境条件下中水平核废料容器的温度测量

Thermometry of intermediate level nuclear waste containers in multiple environmental conditions

J Norman, A Sposito, J L McMillan, W Bond, M Hayes, R Simpson, G Sutton, V Panicker, G Machin, J Jowsey, A Adamska

摘要:

中等水平的核废料必须储存到可以安全地永久处置为止。废物包的温度监测对于核退役工业来说是重要的,以支持每个包的管理。在Sellafield Ltd场地的预期环境储存条件范围内,使用磷光体温度测量和热成像技术监测中水平废物容器的温度:温度为10 °C至25 °C,相对湿度为60%相对湿度至90%相对湿度。在所需的环境条件范围内,从外表面温度测量确定内部温度的可行性已被证明。

英文摘要:

Intermediate level nuclear waste must be stored until it is safe for permanent disposal. Temperature monitoring of waste packages is important to the nuclear decommissioning industry to support management of each package. Phosphor thermometry and thermal imaging have been used to monitor the temperature of intermediate level waste containers within the expected range of environmental storage conditions at the Sellafield Ltd site: temperatures from 10 °C to 25 °C and relative humidities from 60 %rh to 90 %rh. The feasibility of determining internal temperature from external surface temperature measurement in the required range of environmental conditions has been demonstrated.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑