Ryota Kodama, Takeshi Go Tsuru, Takaaki Tanaka, Hiroyuki Uchida, Kazuho Kayama, Yuki Amano, Ayaki Takeda, Koji Mori, Yusuke Nishioka, Masataka Yukumoto, Takahiro Hida, Yasuo Arai, Ikuo Kurachi, Takayoshi Kohmura, Kouichi Hagino, Mitsuki Hayashida, Masatoshi Kitajima, Shoji Kawahito, Keita Yasutomi, Hiroki Kamehama

摘要:

我们一直在开发一种新型的X射线像素传感器“XRPIX”,使我们能够为未来的日本X射线卫星“FORCE”在1-20 keV的宽能量带进行成像光谱学。XRPIX器件采用互补金属氧化物半导体绝缘体上硅技术制造,并具有“事件驱动读出模式”,在该模式下,通过使用来自每个像素配备的触发输出功能的命中信息,仅读取命中事件。本文报道了具有钉扎耗尽二极管(PDD)结构的“XRPIX 6 E”器件的低能X射线性能。PDD结构特别地降低了读出噪声,并且因此预期大大地提高低能量X射线的量子效率。虽然在“帧读出模式”下成功检测到0.68 keV的F-K X射线和1.5 keV的Al-K X射线,但在“帧读出模式”下,所有像素都被串行读出,而不使用触发输出功能,该设备能够检测Al-K X射线,但在事件驱动读出模式下不能检测F-K X射线。在事件驱动读出模式下,在Al-K X射线的计数图中观察到不均匀性,这是由于比较器电路输入处的基座电压的区域到区域变化。最低可用阈值能量为1.1 keV的一个小区域中的设备,其中的非均匀性最小化。电荷敏感放大器在检测节点的噪声和与触发输出功能相关的噪声分别为~ $18~e^-$(rms)和~ $13~e^-$(rms)。

英文摘要:

We have been developing a new type of X-ray pixel sensors, "XRPIX", allowing us to perform imaging spectroscopy in the wide energy band of 1-20 keV for the future Japanese X-ray satellite "FORCE". The XRPIX devices are fabricated with complementary metal-oxide-semiconductor silicon-on-insulator technology, and have the "Event-Driven readout mode", in which only a hit event is read out by using hit information from a trigger output function equipped with each pixel. This paper reports on the low-energy X-ray performance of the "XRPIX6E" device with a Pinned Depleted Diode (PDD) structure. The PDD structure especially reduces the readout noise, and hence is expected to largely improve the quantum efficiencies for low-energy X-rays. While F-K X-rays at 0.68 keV and Al-K X-rays at 1.5 keV are successfully detected in the "Frame readout mode", in which all pixels are read out serially without using the trigger output function, the device is able to detect Al-K X-rays, but not F-K X-rays in the Event-Driven readout mode. Non-uniformity is observed in the counts maps of Al-K X-rays in the Event-Driven readout mode, which is due to region-to-region variation of the pedestal voltages at the input to the comparator circuit. The lowest available threshold energy is 1.1 keV for a small region in the device where the non-uniformity is minimized. The noise of the charge sensitive amplifier at the sense node and the noise related to the trigger output function are ~$18~e^-$ (rms) and ~$13~e^-$ (rms), respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑