arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.08754cond-mat.soft
收藏

一种用于软组织建模的鲁棒各向异性超弹性公式

A robust anisotropic hyperelastic formulation for the modelling of soft tissue

David R. Nolan, Artur L. Gower, Michel Destrade, Ray W. Ogden, Pat McGarry

摘要:

胶原纤维增强材料的各向异性超弹性行为的Holzapfel-Gasser-Ogden(HGO)模型最初是为了描述动脉组织的弹性特性而开发的,但现在广泛用于模拟各种软生物组织。这类材料可以看作是不可压缩的,当采用不可压缩条件时,HGO模型的应变能ε是一个各向同性和两个各向异性变形不变量的函数。可压缩形式(HGO-C模型)被广泛用于有限元模拟中,其中,各向同性的部分被解耦成体积和等容部分,并且各向异性的部分被表示为等容不变量。在这里,通过使用三个简单的变形(纯膨胀,纯剪切和单轴拉伸),我们证明了可压缩HGO-C配方不能正确地模拟可压缩各向异性材料的行为,因为模型的各向异性组件是不敏感的体积变形,由于使用等容各向异性不变量。为了正确地建模可压缩各向异性行为,我们提出了一个修改的各向异性(MA)模型,从而使用完整的各向异性不变量,使体积各向异性的贡献表示。MA模型正确地预测了流体静力拉伸载荷的各向异性响应,即球体变形为椭球体。它还计算了纯剪切和单轴变形的正确各向异性应力状态。为了研究更多的实际应用,我们开发了一个有限元用户定义的材料子程序,用于模拟支架在轻微可压缩动脉中的部署。当使用完全各向异性不变量(MA模型)而不是等容形式(HGO-C模型)时,计算出显著更高的应力三轴性和动脉顺应性。

英文摘要:

The Holzapfel-Gasser-Ogden (HGO) model for anisotropic hyperelastic behaviour of collagen fibre reinforced materials was initially developed to describe the elastic properties of arterial tissue, but is now used extensively for modelling a variety of soft biological tissues. Such materials can be regarded as incompressible, and when the incompressibility condition is adopted the strain energy Ψof the HGO model is a function of one isotropic and two anisotropic deformation invariants. A compressible form (HGO-C model) is widely used in finite element simulations whereby the isotropic part of Ψis decoupled into volumetric and isochoric parts and the anisotropic part of Ψis expressed in terms of isochoric invariants. Here, by using three simple deformations (pure dilatation, pure shear and uniaxial stretch), we demonstrate that the compressible HGO-C formulation does not correctly model compressible anisotropic material behaviour, because the anisotropic component of the model is insensitive to volumetric deformation due to the use of isochoric anisotropic invariants. In order to correctly model compressible anisotropic behaviour we present a modified anisotropic (MA) model, whereby the full anisotropic invariants are used, so that a volumetric anisotropic contribution is represented. The MA model correctly predicts an anisotropic response to hydrostatic tensile loading, whereby a sphere deforms into an ellipsoid. It also computes the correct anisotropic stress state for pure shear and uniaxial deformation. To look at more practical applications, we developed a finite element user-defined material subroutine for the simulation of stent deployment in a slightly compressible artery. Significantly higher stress triaxiality and arterial compliance are computed when the full anisotropic invariants are used (MA model) instead of the isochoric form (HGO-C model).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑