arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1510.00537q-bio.TOcond-mat.soft
收藏

一种新的基于纤维束微结构的韧带和肌腱超弹性模型的应变能函数

A new strain energy function for the hyperelastic modelling of ligaments and tendons based on fascicle microstructure

Tom Shearer

摘要:

基于韧带和肌腱原纤维的几何排列,提出了一种新的用于超弹性建模的应变能函数。原纤维的卷曲角的分布用于确定单个纤维束的应力-应变响应,并且该应力-应变响应用于确定应变能函数的形式,其参数都可以潜在地通过实验直接测量-不像常用的应变能函数,例如Holzapfel-Gasser-Ogden(HGO)模型,其参数是现象学的。我们将新模型与HGO模型进行了比较,结果表明,新模型比HGO模型更好地匹配人类髌腱的现有应力-应变数据,使用新模型时匹配此数据的平均相对误差为0.053(与使用HGO模型时的0.57相比),并且使用新模型时的平均绝对误差为0.12MPa(与使用HGO模型时的0.31MPa相比)。

英文摘要:

A new strain energy function for the hyperelastic modelling of ligaments and tendons based on the geometrical arrangement of their fibrils is derived. The distribution of the crimp angles of the fibrils is used to determine the stress-strain response of a single fascicle, and this stress-strain response is used to determine the form of the strain energy function, the parameters of which can all potentially be directly measured via experiments - unlike those of commonly used strain energy functions such as the Holzapfel-Gasser-Ogden (HGO) model, whose parameters are phenomenological. We compare the new model with the HGO model and show that the new model gives a better match to existing stress-strain data for human patellar tendon than the HGO model, with the average relative error in matching this data when using the new model being 0.053 (compared with 0.57 when using the HGO model), and the average absolute error when using the new model being 0.12 MPa (compared with 0.31 MPa when using the HGO model).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑