This paper describes a new method for optical readout of Time Projection Chambers (TPCs), based on the Linearly Graded Silicon Photomultiplier (LG-SiPM). This is a single photon-sensitive detector with excellent timing and 2D position resolution developed at Fondazione Bruno Kessler, Trento (FBK). The LG-SiPM produces time-varying voltage signals that are used to reconstruct the 3D position and energy of ionisation tracks generated inside the TPC. The TPC used in this work contained room-temperature CF$_4$ gas at a pressure of 100 mbar, with two THGEMs to produce secondary scintillation light. A collimated $^{241}$Am source (Q$_α$ = 5.486 MeV) was used to produce the ionisation tracks. The successful reconstruction of these tracks is demonstrated, and the consistency of the methodology characterised through varying the geometry of the tracks within the TPC. Energy reconstruction and deposition studies are also described, demonstrating the feasibility of the LG-SiPM as a potential option for optical TPC readout.
Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.
In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is always one of research focus. In this paper, a SiPM readout pre-amplifier based on common-base current amplifier structure followed by a Pole-Zero (PZ) compensation network is constructed, and the main factors that affect the timing performance of the PET detector are investigated. By experimental measurement, we found that the CTR is heavily related to the ba…
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on ZnS:${}^6$LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current ${}^3$He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
Compact X-rays detectors made of 1/2 inch Ce:LaBr3 crystals of cubic shape with SiPM array readout have been developed for the FAMUexperiment at RIKEN-RAL, to instrument regions of difficult access. Due to the high photon yield of Ce:LaBr3 it was possible to use a simple readout scheme based on CAEN V1730 digitizers, without a dedicated amplification stage. The drift with temperature of SiPM gain was corrected by using CAEN A7885D regulated power supply chips with temperature feedback. Energy resolutions (FWHM) around 3:5% at the 137Cs peak and around 9% at the 57Co peak were obtained.
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided…
We have developed a dedicated front-end-electronics board for a high-pressure xenon gas time projection chamber for a neutrinoless double-beta decay search. The ionization signal is readout by detecting electroluminescence photons with SiPM's. The board readout the signal from 56~SiPM's through the DC-coupling and record the waveforms at 5 MS/s with a wide dynamic range up to 7,000 photons/200 ns. The SiPM bias voltages are provided by the board and can be adjusted for each SiPM. In order to calibrate and monitor the SiPM gain, additional auxiliary ADC measures 1 photon-equivalent dark current…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle identification via time-of-flight measurements. Scintillation light is collected by photosensors coupled to both ends of every bar. In this article, we present our study on a direct replacement of commonly used vacuum photomultiplier tubes (PMTs) by arrays of large-area silicon photomultipliers (SiPMs). An SiPM array which is directly coupled to the scintillator …
LaB$_3$:Ce crystals have been introduced for radiation imaging in medical physics, with photomultiplier or single SiPM readout. An R-D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm$^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution, good detector linearity and fast time response for low-energy X-rays. A natural application was found inside the FAMU project at RIKEN-RAL muon facility, that aims at a precise measure of the proton Zemach radius to solve the so-called "proton radi…
Silicon Photomultipliers (SiPMs) are an excellent candidate for the development of large-area light sensors. Large SiPM-based detectors require low-noise pre-amplifiers to maximize the signal coupling between the sensor and the readout electronics. This article reports on the development of a low-noise transimpedance amplifier sensitive to single-photon signals at cryogenic temperature. The amplifier is used to readout a 1 cm$^{2}$ SiPM with a signal to noise ratio in excess of 40.
LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm $^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution,good detector linearity and fast time response for low-energy X-rays. The study was triggered by the FAMU experiment at the RIKEN-RAL muon facility, aiming at a precise measurement of the proton Zemach radius to solve the so-called…
We describe a novel high-speed front-end electronic board (FEB) for interfacing an array of 32 Silicon Photo-multipliers (SiPM) with a computer. The FEB provides individually adjustable bias on the SiPMs, and performs low-noise analog signal amplification, conditioning and digitization. It provides event timing information accurate to 1.3 ns RMS. The back-end data interface is realized on the basis of 100 Mbps Ethernet. The design allows daisy-chaining of up to 256 units into one network interface, thus enabling compact and efficient readout schemes for multi-channel scintillating detectors, u…
A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each pad layer is required to provide a spatial resolution of ~250 microns, which must be achieved with a minimal channel count in order to minimize the overall cost of the detector. The current proposal is to make the pads into a zigzag shape in order to enhance charge sharing among neighboring pads. This will allow for the possibility to interpolate the hit pos…
The ARIADNE project is developing innovative optical readout technologies for two-phase liquid Argon time projection chambers (LArTPCs). Optical readout presents an exciting alternative to the current paradigm of charge readout. Optical readout is simple, scalable and cost effective. This paper presents first demonstration of 3D optical readout of TPC, using CF4 gas as a proof of principle. Both cosmic rays and an Americium-241 alpha source have been imaged in 100 mbar CF4. A single-photon sensitive camera was developed by combining a Timepix3 (TPX3) based camera with an image intensifier. Whe…
Resolution studies of cosmic-ray tracks in a TPC with GEM readout
大体积TPC是未来高能直线对撞机中心跟踪探测器的首选。为了提高分辨率,正在开发一种基于微图案气体探测器的新读出器。测量了GEM TPC中宇宙线径迹的空间分辨率。我们发现,分辨率遭受如果读出垫是太宽的相对于在读出平面上的电荷分布,由于不充分的电荷共享。对于2 x 6 mm**2的窄垫,在没有轴向磁场的情况下,我们在短漂移距离处测量到100微米的分辨率。作为漂移距离的函数的空间分辨率的依赖性允许确定潜在的电子统计。我们的研究结果表明,本技术使用约一半的统计功率可从初级电子的数量。跟踪角效应如预期的那样被观察到。
The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained with different configurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230 photo-electrons, and an efficiency better than 99.8 $\%$ are obtained with $\sim 225$ cm$^2$ large area tiles. This technology is suitable for a wide range …
Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3 % (8 %) at the Cs137 Co57) peak…
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and turn-off voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. The fluence dependence of gain and turn-off voltage are reported. A reduction of the gain by 19% and an increase of $V_{off}$ by $\approx$0.5 V is observed after $Φ$ = 5e13 cm$^{-2}$.
The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. In order to record at an increased interaction rate of up to 50$\,$kHz in Pb$-$Pb collisions, the TPC will be operated in an ungated mode with continuous readout. This demands for a replacement of the currently employed gated Multi-Wire Proportional Chambers by GEM-based (Gas Electron Multiplier) readout chambers, while retaining the performance in particular in terms of particle identification capabilities via the measurement of the specific ene…
This work presents the design and performance study of compact strips of plastic scintillator with WLS-fiber readout in a dimension of 0.1 * 0.02 * 2 m3, which evaluates as a candidate for cosmic-ray muon detector for JUNO-TAO. The strips coupling with 3-inch PMTs are measured and compared between the single-end and double-end readout options first, and the strip of double-end option coupling with SiPM is further measured and compared with the results of that with the PMTs. The performance of the strips determined by a detailed survey along their length with cosmic-ray muon after a detailed ch…
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to $120\times40\times5$ mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioacti…
Multiplexed SiPM Readout of Plastic Scintillating Fiber Detector for Muon Tomography
Institute for Advanced Technology, Shandong University(山东大学前沿技术研究院);Particle Physics Research Center, Shandong Institute of Advanced Technology(山东大学前沿技术研究院粒子物理研究中心)
A novel detector for the ionization signal in a single phase LAr-TPC, based on the adoption of a multilayer Large Electron Multiplier (LEM) replacing the traditional anodic wire arrays, has been experimented in the ICARINO test facility at the INFN Laboratories in Legnaro. Cosmic muon tracks were detected allowing the measurement of energy deposition and a first determination of the signal to noise ratio. The analysis of the recorded events demonstrated the 3D reconstruction capability of ionizing events in this device in liquid Argon, collecting a fraction of about 90% of the ionization signa…
For the International Large Detector (ILD), foreseen to be built at the International Linear Collider (ILC), a Time Projection Chamber (TPC) is intended to be used as the main tracking detector. The amplification will be provided by Micro Pattern Gaseous Detectors (MPGDs). One option is the use of Gas Electron Multipliers (GEM) in combination with a segmented pad readout plane. The TPC group at DESY developed a modular system implementing a triple GEM stack mounted on thin ceramic grids. This material choice allows for high mechanical rigidity of the support structure at a reduced amount of ma…
Very little work has been done searching for astrophysical transient optical emission in the millisecond to nanosecond regime with significant sensitivity. We call this regime "Ultra-Fast Astronomy", or UFA. To investigate transients on as short time scales as possible, we developed our own customized readout system for a silicon photomultiplier (SiPM)-based UFA camera, intended for use on conventional astronomical telescopes. SiPMs, available in array packages for imaging a field, are capable of time-tagged single-photon detection in the visible wavelength range. Our readout system consists o…
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, inducing electroluminescence within the bubble. The resulting photons are detected with a Hamamatsu VUV4 quad-SiPM array - providing the deposited energy with a charge-only RMS resolution of 6.6%. The image…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90\times 40\times 5~\mathrm{mm}^3$ readout by six SiPMs (three on each $40\times 5~\mathrm{mm}^2$ plane) were built with SiPMs from …
The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas mixture at atmospheric pressure. Optical readout with high granularity CMOS sensors, combined with fast light detectors, will provide a detailed reconstruction of the event topology. This will allow to discriminate the nuclear recoil signal from the background, mainly represented by low energy electron recoils induced by radioactivity. Thanks to the high recons…
Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for such purposes with large active areas and high efficiency. A gaseous TPC with a Micromegas readout plane of approximately 20$\times$20 cm$^2$ is successfully constructed for surface alpha contamination measurements. We have characterized the energy resolution, gain stability, and tracking capability with calibration sources. With the unique track-related ba…
Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for low-energy and rare event studies, such as Dark Matter search, ask for demanding performance in the keV energy range. The performance of such a readout was studied in details as a function of the electric field configuration and GEM gain by using a $^{55}$Fe source within a 7 litre sensitive volume detector developed as a part of the R\&D for the CYGNUS project.…
A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the particle position perpendicular to the image plane. A hybrid readout TPC working at high pressure is an attractive device for physics cases where an excellent space point resolution and a high target density is required as e.g. measuring a neutrino beam at the source of a long baseline neutrino oscillation experiment. In this paper we present two different l…
Cherenkov and scintillation light separation in BGO and BSO crystals coupled to SiPMs for dual-readout electromagnetic calorimetry at future colliders
Università degli Studi di Napoli Federico II(那不勒斯费德里科二世大学);Istituto Nazionale di Fisica Nucleare, Sezione di Napoli(意大利国家核物理研究所,那不勒斯分部);Università degli Studi di Napoli Parthenope(那不勒斯帕尔特诺佩大学);European Center for the Nuclear Research(欧洲核子研究中心);Istituto Nazionale di Fisica Nucleare, Sezione di Milano-Bicocca(意大利国家核物理研究所,米兰比可卡分部);Dipartimento di Fisica e Geologia, Università degli Studi di Perugia(佩鲁贾大学物理与地质学系);Istituto Nazionale di Fisica Nucleare, Sezione di Perugia(意大利国家核物理研究所,佩鲁贾分部);Scuola Superiore Meridionale(南方高等学院)
A high momentum resolution is required for the precision measurement of Higgs boson at the International Linear Collider (ILC) using the recoil mass technique. The International Large Detector (ILD) is designed to meet this requirement by an MPGD-readout Time Projection Chamber (TPC) providing about 200 sample points each with a spatial resolution of 100 $μ$m operated in a magnetic field of 3.5 T. However, there is a potential problem that many positive ions generated in the gas amplification process in the end-plane detector modules would flow back into the drift volume of the TPC and distort…
The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs with large detection area have recently become commercially available, enabling applications where the photon flux is low both temporarily and spatially. On the other hand, several drawbacks exist in the usage of SiPMs such as a higher dark count rate, many readout channels, slow response time, and optical crosstalk; therefore, users need to carefully conside…
Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode
国际直线对撞机(ILC)的TPC将需要测量大约200个轨道点,横向分辨率接近100微米。分辨率的目标是超越传统的比例线/阴极垫TPC和微图案气体检测器(MPGD)的能力正在开发,以满足这一挑战。然而,标准MPGD读出技术将难以实现如最初设想的具有2 mm X 6 mm焊盘的ILC-TPC分辨率目标。对较小宽度焊盘的提议将提高分辨率,但将需要更大数量的读出通道并增加TPC检测器的成本和复杂性。电荷分散的新MPGD读出概念具有在不诉诸较窄焊盘的情况下实现ILC-TPC分辨率目标的潜力。这是最近在宇宙射线测试的一个小型原型TPC读出MPGD使用电荷分散技术证明。在这里,我们描述的电荷分散现象的MPGD-TPC的模拟。详细的模拟包括初始电离团簇、电子漂移、扩散效应、本征探测器脉冲形状和电子学效应。模拟结果与实验数据吻合良好,可用于优化TPC的MPGD电荷色散读出。
In this paper we discuss a general approach to use SiPMs in different electrical configurations in combination with numerous scintillator materials for applications in nuclear instrumentation, such as calorimetry and timing. The "hybrid" configuration used in the PANDA detector was found to show the fastest timing properties with several hundred pico second response by combining the advantages of a large active area while avoiding high operation voltages and dark noise. A "parallel" configuration shows the largest light collection efficiency and is therefore suitable for energy measurements. S…