arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.03010quant-phcond-mat.mes-hallcond-mat.supr-conphysics.app-ph
收藏

用匹配的温度可变噪声源表征低温放大器

Characterizing cryogenic amplifiers with a matched temperature-variable noise source

Slawomir Simbierowicz, Visa Vesterinen, Joshua Milem, Aleksi Lintunen, Mika Oksanen, Leif Roschier, Leif Grönberg, Juha Hassel, David Gunnarsson, Russell E. Lake

摘要:

本文介绍了一种特性阻抗为50 $Ω$的低温微波噪声源,它可以安装在低温恒温器的同轴线上。噪声源的浴温度在0.1 K和5 K之间连续变化,而不会对样品空间造成显著的反作用加热。作为一个概念验证实验,我们进行Y因子测量的放大器级联,包括行波参量放大器和商业高电子迁移率晶体管放大器。我们观察到系统的噪声温度低至$680^{+20}_{-200}$ mK在5.7 GHz对应于$1.5^{+0.1}_{-0.7}$多余的光子。我们提出的系统在固态量子位读出线的验证中具有直接的应用。

英文摘要:

We present a cryogenic microwave noise source with a characteristic impedance of 50 $Ω$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as $680^{+20}_{-200}$ mK at 5.7 GHz corresponding to $1.5^{+0.1}_{-0.7}$ excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑