用于调节热泵和光伏系统的最佳家庭能量管理系统

An optimal home energy management system for modulating heat pumps and photovoltaic systems

Lissy Langer, Thomas Volling

摘要:

高效的住宅部门耦合在支持能源转型方面发挥着关键作用。在这项研究中,我们分析了与家庭能源管理系统的最优控制和常见的技术配置和目标的影响的结构特性。我们进行这项研究,通过模拟一个具有代表性的建筑与调制空气源热泵,光伏(PV)系统,电池和蓄热系统的地板采暖和热水供应。此外,我们通过假设固定上网电价允许电网上网,并考虑用户舒适度。在我们的数值分析中,我们发现电池自然是提高自给自足的重要组成部分。然而,为了有效地利用光伏盈余,电网馈入是必要的。在给定的关税结构下,通常考虑的最大限度地实现自我消费的目标在经济上是不可行的;然而,通过最大限度地实现自给自足,可以实现接近最佳性能和大幅减少解决时间。基于最优控制并考虑季节性影响,可以得到光伏分布的优势阶数和蓄能系统的目标荷电状态。使用滚动时域方法,求解时间可以减少到不到1分钟(实现每年1小时的时间分辨率)。通过评估信息的价值,我们发现,24小时的预测和控制视野的共同价值的结果在无意中,但可以避免的视野结束的影响。我们使用Julia JuMP编程语言开发的输入数据和混合整数线性模型以开源方式提供。

英文摘要:

Efficient residential sector coupling plays a key role in supporting the energy transition. In this study, we analyze the structural properties associated with the optimal control of a home energy management system and the effects of common technological configurations and objectives. We conduct this study by modeling a representative building with a modulating air-sourced heat pump, a photovoltaic (PV) system, a battery, and thermal storage systems for floor heating and hot-water supply. In addition, we allow grid feed-in by assuming fixed feed-in tariffs and consider user comfort. In our numerical analysis, we find that the battery, naturally, is the essential building block for improving self-sufficiency. However, in order to use the PV surplus efficiently grid feed-in is necessary. The commonly considered objective of maximizing self-consumption is not economically viable under the given tariff structure; however, close-to-optimal performance and significant reduction in solution times can be achieved by maximizing self-sufficiency. Based on optimal control and considering seasonal effects, the dominant order of PV distribution and the target states of charge of the storage systems can be derived. Using a rolling horizon approach, the solution time can be reduced to less than 1 min (achieving a time resolution of 1 h per year). By evaluating the value of information, we find that the common value of 24 h for the prediction and control horizons results in unintended but avoidable end-of-horizon effects. Our input data and mixed-integer linear model developed using the Julia JuMP programming language are available in an open-source manner.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑