T2 Mapping from Super-Resolution-Reconstructed Clinical Fast Spin Echo Magnetic Resonance Acquisitions
Hélène Lajous, Tom Hilbert, Christopher W. Roy, Sébastien Tourbier, Priscille de Dumast, Thomas Yu, Jean-Philippe Thiran, Jean-Baptiste Ledoux, Davide Piccini, … 展开作者
Hélène Lajous, Tom Hilbert, Christopher W. Roy, Sébastien Tourbier, Priscille de Dumast, Thomas Yu, Jean-Philippe Thiran, Jean-Baptiste Ledoux, Davide Piccini, Patric Hagmann, Reto Meuli, Tobias Kober, Matthias Stuber, Ruud B. van Heeswijk, Meritxell Bach Cuadra
备注:
11 pages, 4 figures, 1 table, 1 supplement, to appear in Proceedings in Medical Image Computing and Computer Assisted Intervention (MICCAI), Peru, October 2020
Relaxometry studies in preterm and at-term newborns have provided insight into brain microstructure, thus opening new avenues for studying normal brain development and supporting diagnosis in equivocal neurological situations. However, such quantitative techniques require long acquisition times and therefore cannot be straightforwardly translated to in utero brain developmental studies. In clinical fetal brain magnetic resonance imaging routine, 2D low-resolution T2-weighted fast spin echo sequences are used to minimize the effects of unpredictable fetal motion during acquisition. As super-resolution techniques make it possible to reconstruct a 3D high-resolution volume of the fetal brain from clinical low-resolution images, their combination with quantitative acquisition schemes could provide fast and accurate T2 measurements. In this context, the present work demonstrates the feasibility of using super-resolution reconstruction from conventional T2-weighted fast spin echo sequences for 3D isotropic T2 mapping. A quantitative magnetic resonance phantom was imaged using a clinical T2-weighted fast spin echo sequence at variable echo time to allow for super-resolution reconstruction at every echo time and subsequent T2 mapping of samples whose relaxometric properties are close to those of fetal brain tissue. We demonstrate that this approach is highly repeatable, accurate and robust when using six echo times (total acquisition time under 9 minutes) as compared to gold-standard single-echo spin echo sequences (several hours for one single 2D slice).
Quantitative imaging in MRI usually involves acquisition and reconstruction of a series of images at multi-echo time points, which possibly requires more scan time and specific reconstruction technique compared to conventional qualitative imaging. In this work, we focus on optimizing the acquisition and reconstruction process of multi-echo gradient echo pulse sequence for quantitative susceptibility mapping as one important quantitative imaging method in MRI. A multi-echo sampling pattern optimization block extended from LOUPE-ST is proposed to optimize the k-space sampling patterns along echo…
There has been increased interest in the quantitative characterization of tissues based on T2 in abdominal imaging. Techniques based on spin-echo or turbo spin-echo sequences are time consuming because they require multiple acquisitions for obtaining an adequate number of TE images for accurate T2 mapping. Radial turbo spin echo (RADTSE) based methods have been shown to generate accurate T2 maps from a single acquisition using highly undersampled data. In this work, we present details of the RADTSE technique, summarizing developments related to the design of pulse sequence and reconstruction a…
Multi-shot echo planar imaging (msEPI) is a promising approach to achieve high in-plane resolution with high sampling efficiency and low T2* blurring. However, due to the geometric distortion, shot-to-shot phase variations and potential subject motion, msEPI continues to be a challenge in MRI. In this work, we introduce acquisition and reconstruction strategies for robust, high-quality msEPI without phase navigators. We propose Blip Up-Down Acquisition (BUDA) using interleaved blip-up and -down phase encoding, and incorporate B0 forward-modeling into Hankel structured low-rank model to enable …
Purpose: To rapidly obtain high isotropic-resolution T2 maps with whole-brain coverage and high geometric fidelity. Methods: A T2 blip-up/down echo planar imaging (EPI) acquisition with generalized Slice-dithered enhanced resolution (T2-BUDA-gSlider) is proposed. A radiofrequency (RF)-encoded multi-slab spin-echo EPI acquisition with multiple echo times (TEs) was developed to obtain high SNR efficiency with reduced repetition time (TR). This was combined with an interleaved 2-shot EPI acquisition using blip-up/down phase encoding. An estimated field map was incorporated into the joint multi-sh…
Cornell University(康奈尔大学);Weill Medical College of Cornell University(康奈尔大学威尔医学院)
Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE) pulse sequence for QSM. Our approach involves optimizing a Cartesian multi-echo k-space sampling pattern with a deep reconstruction network. Next, this optimized sampling pattern was implemented in …
Purpose: This work aims to develop a novel distortion-free 3D-EPI acquisition and image reconstruction technique for fast and robust, high-resolution, whole-brain imaging as well as quantitative T2* mapping. Methods: 3D-Blip-Up and -Down Acquisition (3D-BUDA) sequence is designed for both single- and multi-echo 3D GRE-EPI imaging using multiple shots with blip-up and -down readouts to encode B0 field map information. Complementary k-space coverage is achieved using controlled aliasing in parallel imaging (CAIPI) sampling across the shots. For image reconstruction, an iterative hard-thresholdin…
Spin-echo functional MRI (SE-fMRI) has the potential to improve spatial specificity when compared to gradient-echo fMRI. However, high spatiotemporal resolution SE-fMRI with large slice-coverage is challenging as SE-fMRI requires a long echo time (TE) to generate blood oxygenation level-dependent (BOLD) contrast, leading to long repetition times (TR). The aim of this work is to develop an acquisition method that enhances the slice-coverage of SE-fMRI at high spatiotemporal resolution. An acquisition scheme was developed entitled Multisection Excitation by Simultaneous Spin-echo Interleaving (M…
Motion and temporal B0 shift corrections for quantitative susceptibility mapping (QSM) and R2* mapping using dual-echo spiral navigators and conjugate-phase reconstruction
Use of synthetic data has provided a potential solution for addressing unavailable or insufficient training samples in deep learning-based magnetic resonance imaging (MRI). However, the challenge brought by domain gap between synthetic and real data is usually encountered, especially under complex experimental conditions. In this study, by combining Bloch simulation and general MRI models, we propose a framework for addressing the lack of training data in supervised learning scenarios, termed MOST-DL. A challenging application is demonstrated to verify the proposed framework and achieve motion…
Purpose: To develop an accelerated Cartesian MRF implementation using a multi-shot EPI sequence for rapid simultaneous quantification of T1 and T2 parameters. Methods: The proposed Cartesian MRF method involved the acquisition of highly subsampled MR images using a 16-shot EPI readout. A linearly varying flip angle train was used for rapid, simultaneous T1 and T2 quantification. The accuracy of parametric map estimations were improved by using an iterative projection algorithm. The results were compared to a conventional spiral MRF implementation. The acquisition time per slice was 8s and this…
To rapidly obtain high resolution T2, T2* and quantitative susceptibility mapping (QSM) source separation maps with whole-brain coverage and high geometric fidelity. We propose Blip Up-Down Acquisition for Spin And Gradient Echo imaging (BUDA-SAGE), an efficient echo-planar imaging (EPI) sequence for quantitative mapping. The acquisition includes multiple T2*-, T2'- and T2-weighted contrasts. We alternate the phase-encoding polarities across the interleaved shots in this multi-shot navigator-free acquisition. A field map estimated from interim reconstructions was incorporated into the joint mu…
T2 weighted imaging of the spine is commonly performed using fast spin echo (FSE/TSE) based sequences, resulting in long scan times and vulnerability to motion artifacts. While single shot fast spin echo sequences have been attempted, their adoption has been limited by poor spatial resolution and specific absorption rate (SAR) limitations. We investigate the use of a half-Fourier acquisition single-shot turbo spin-echo variable flip angle (HASTE-VFA) sequence for T2 weighted spine imaging. A variable refocusing flip angle echo train was first optimized for the spine to improve the point spread…
Motion-Robust T2* Quantification from Gradient Echo MRI with Physics-Informed Deep Learning
Institute of Machine Learning in Biomedical Imaging , Helmholtz Munich , Germany;School of Computation, Information \& Technology , Technical University of Munich , Germany;School of Medicine \& Health, Institute for Diagnostic;Interventional Neuroradiology , Technical University of Munich , Germany;School of Medicine \& Health, TUM-Neuroimaging Center , Technical University of Munich , Germany;Philips GmbH Market DACH , Germany;School of Medicine \& Health, Clinic of Neurology , Technical University of Munich , Germany;School of Biomedical Engineering \& Imaging Sciences , King’s College London , UK
Obtaining high quality images of the spinal cord with MRI is difficult, partly due to the fact that the spinal cord is surrounded by a number of structures that have differing magnetic susceptibility. This causes inhomogeneities in the magnetic field, which in turn lead to image artifacts. In order to address this issue, linear compensation gradients can be employed. The latter can be generated using an MRI scanner's first order gradient coils and adjusted on a per-slice basis, in order to correct for through-plane ("z") magnetic field gradients. This approach is referred to as z-shimming. The…
GDCNet: Calibrationless geometric distortion correction of echo planar imaging data using deep learning
Columbia University in the City of New York(纽约市哥伦比亚大学);Icahn School of Medicine at Mount Sinai(西奈山伊坎医学院);Columbia University Medical Center(哥伦比亚大学医学中心);John Hopkins University(约翰斯·霍普金斯大学)
Purpose: To demonstrate an ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) method that can simultaneously quantify tissue relaxometries for muscle and bone in musculoskeletal systems and tissue components in brain and therefore can synthesize pseudo-CT images. Methods: A FISP-MRF sequence with half pulse excitation and half spoke radial acquisition was designed to sample fast T2 decay signals. Sinusoidal echo time (TE) pattern was applied to enhance MRF sensitivity for tissues with short and ultrashort T2 values. The performance of UTE-MRF was evaluated via simulations, phanto…
Indraprastha Institute of Information Technology(因德拉普拉斯信息技术学院)
Multi-echo magnetic resonance (MR) images are acquired by changing the echo times (for T2 weighted) or relaxation times (for T1 weighted) of scans. The resulting (multi-echo) images are usually used for quantitative MR imaging. Acquiring MR images is a slow process and acquiring multi scans of the same cross section for multi-echo imaging is even slower. In order to accelerate the scan, compressed sensing (CS) based techniques have been advocating partial K-space (Fourier domain) scans; the resulting images are reconstructed via structured CS algorithms. In recent times, it has been shown that…
Two-dimensional (2D) fast spin echo (FSE) techniques play a central role in the clinical magnetic resonance imaging (MRI) of knee joints. Moreover, three-dimensional (3D) FSE provides high-isotropic-resolution magnetic resonance (MR) images of knee joints, but it has a reduced signal-to-noise ratio compared to 2D FSE. Deep-learning denoising methods are a promising approach for denoising MR images, but they are often trained using synthetic noise due to challenges in obtaining true noise distributions for MR images. In this study, inherent true noise information from 2-NEX acquisition was used…
Motion-robust 2D Radial Turbo Spin Echo (RADTSE) pulse sequence can provide a high-resolution composite image, T2-weighted images at multiple echo times (TEs), and a quantitative T2 map, all from a single k-space acquisition. In this work, we use a deep-learning convolutional neural network (CNN) for the segmentation of liver in abdominal RADTSE images. A modified UNET architecture with generalized dice loss objective function was implemented. Three 2D CNNs were trained, one for each image type obtained from the RADTSE sequence. On evaluating the performance of the CNNs on the validation set, …
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy. Methods: k-space data are continuously acquired using a rewound Cartesian acquisition with spiral profile ordering (rCASPR) to provide matching contrast to the conventional linear phase encode ordering and to sort data into multiple respiratory phases. Low-resolution respiratory-correlated 4D images were reconstructed with compressed sensing and used to estimate non-rigid deformation vector fields,…
We introduce wave encoded acquisition and reconstruction techniques for highly accelerated echo planar imaging (EPI) with reduced g-factor penalty and image artifacts. Wave-EPI involves playing sinusoidal gradients during the EPI readout while employing interslice shifts as in blipped-CAIPI acquisitions. This spreads the aliasing in all spatial directions, thereby taking better advantage of 3D coil sensitivity profiles. The amount of voxel spreading that can be achieved by the wave gradients during the short EPI readout period is constrained by the slew rate of the gradient coils and periphera…
Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-imaging. They are robust to flow and motion, have diffuse aliasing patterns, and support short readouts and echo times. One drawback is that standard implementations do not support anisotropic field-of-view (FOV) shapes, which are used to match the imaging parameters to the object or region-of-interest. A set of fast, simple algorithms for 2-D and 3-D PR, and 3-D cones acquisitions are introduced that match the sampling density in frequency…
Lausanne University Hospital (CHUV)(洛桑大学医院);University of Lausanne (UNIL)(洛桑大学);CIBM Center for Biomedical Imaging(CIBM生物医学成像中心);Siemens Healthcare(西门子医疗);Ecole Polytechnique Fédérale de Lausanne (EPFL)(洛桑联邦理工学院)
Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of sensitive subjects remains scarce, thus hindering the validation of advanced image processing techniques. Numerical phantoms can mitigate these limitations by providing a controlled environment with a …
Purpose: Thalamic nuclei are largely invisible in conventional MRI due to poor contrast. Thalamus Optimized Multi-Atlas Segmentation (THOMAS) provides automatic segmentation of 12 thalamic nuclei using white-matter-nulled (WMn) MPRAGE sequence at 7T. Application of THOMAS to Magnetization Prepared 2 Rapid Gradient Echo (MP2RAGE) sequence acquired at 7T has been investigated in this study. Methods: 8 healthy volunteers and 5 pediatric-onset multiple sclerosis patients were recruited at the Children's Hospital of Philadelphia and scanned at Siemens 7T with WMn-MPRAGE and multi-echo MP2RAGE (ME-M…
University of Amsterdam(阿姆斯特丹大学);Facebook AI Research(Facebook人工智能研究院)
Most current approaches to undersampled multi-coil MRI reconstruction focus on learning the reconstruction model for a fixed, equidistant acquisition trajectory. In this paper, we study the problem of joint learning of the reconstruction model together with acquisition policies. To this end, we extend the End-to-End Variational Network with learnable acquisition policies that can adapt to different data points. We validate our model on a coil-compressed version of the large scale undersampled multi-coil fastMRI dataset using two undersampling factors: $4\times$ and $8\times$. Our experiments s…
Arizona State University(亚利桑那州立大学);Barrow Neurological Institute(巴罗神经学研究所);Mayo Clinic Arizona(亚利桑那州梅奥诊所)
Typical Magnetic Resonance Imaging (MRI) scan may take 20 to 60 minutes. Reducing MRI scan time is beneficial for both patient experience and cost considerations. Accelerated MRI scan may be achieved by acquiring less amount of k-space data (down-sampling in the k-space). However, this leads to lower resolution and aliasing artifacts for the reconstructed images. There are many existing approaches for attempting to reconstruct high-quality images from down-sampled k-space data, with varying complexity and performance. In recent years, deep-learning approaches have been proposed for this task, …
In this work, we proposed a continuous-acquisition strategy using a gradient echo (GRE) inversion recovery sequence based on spiral trajectories to simultaneously obtain the $T_1$ mapping and CINE imaging. The acquisition is using a free-breathing and ungated fashion. An approach based on variational auto-encoder(VAE) is used for the motion estimation from the centered k-space data. The motion signal is then used to train a deep manifold reconstruction algorithm for image reconstruction. Once the network is trained, we can excite the latent vectors (the estimated motion signals and the contras…
Korea University(高丽大学);Korea Basic Science Institute(韩国基础科学研究院);Korea Artificial Organ Center(韩国人工器官中心);ICT Convergence Technology for Health and Safety(健康安全信息通信融合技术);Department of Electronics and Information Engineering(电子与信息工程系);Bioimaging Research Team(生物成像研究团队)
Purpose: To acquire the real-time interactive temperature map for aqueous and adipose tissue, the problems of long acquisition and processing time must be addressed. To overcome these major challenges, this paper proposes a cascaded convolutional neural network (CNN) framework and multi-echo gradient echo (meGRE) with a single reference variable flip angle (srVFA). Methods: To optimize the echo times for each method, MR images are acquired using a meGRE sequence; meGRE images with two flip angles (FAs) and meGRE images with a single FA are acquired during the pretreatment and treatment stages,…
Wellcome Centre for Human Neuroimaging, Queen Square Institute of Neurology, University College London(伦敦大学学院皇后广场神经病学研究所惠康人类神经影像中心);Spinal Cord Injury Center Balgrist, University Hospital Zurich, University of Zurich(苏黎世大学医院巴尔格里斯特脊髓损伤中心,苏黎世大学)
Quantitative magnetic resonance imaging (qMRI) derives tissue-specific parameters -- such as the apparent transverse relaxation rate R2*, the longitudinal relaxation rate R1 and the magnetisation transfer saturation -- that can be compared across sites and scanners and carry important information about the underlying microstructure. The multi-parameter mapping (MPM) protocol takes advantage of multi-echo acquisitions with variable flip angles to extract these parameters in a clinically acceptable scan time. In this context, ESTATICS performs a joint loglinear fit of multiple echo series to ext…
Friedrich-Alexander Universität Erlangen-Nürnberg(弗里德里希-亚历山大大学埃尔兰根-纽伦堡分校);Technical University of Applied Sciences Amberg-Weiden(安贝格-魏登应用技术大学);Siemens Healthcare GmbH(西门子医疗有限公司)
A Magnetic Resonance Imaging (MRI) exam typically consists of the acquisition of multiple MR pulse sequences, which are required for a reliable diagnosis. Each sequence can be parameterized through multiple acquisition parameters affecting MR image contrast, signal-to-noise ratio, resolution, or scan time. With the rise of generative deep learning models, approaches for the synthesis of MR images are developed to either synthesize additional MR contrasts, generate synthetic data, or augment existing data for AI training. However, current generative approaches for the synthesis of MR images are…
Friedrich-Alexander Universität Erlangen-Nürnberg(弗里德里希-亚历山大大学埃尔兰根-纽伦堡分校);Technical University of Applied Sciences Amberg-Weiden(安贝格-魏登应用技术大学);Siemens Healthineers(西门子医疗)
Purpose A Magnetic Resonance Imaging (MRI) exam typically consists of several sequences that yield different image contrasts. Each sequence is parameterized through multiple acquisition parameters that influence image contrast, signal-to-noise ratio, acquisition time, and/or resolution. Depending on the clinical indication, different contrasts are required by the radiologist to make a diagnosis. As MR sequence acquisition is time consuming and acquired images may be corrupted due to motion, a method to synthesize MR images with adjustable contrast properties is required. Methods Therefore, we …