Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. R. Angevaare, F. Arneodo, D. … 展开作者
The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. R. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino, M. Clark, D. Coderre, A. P. Colijn, J. Conrad, J. P. Cussonneau, M. P. Decowski, A. Depoian, P. Di Gangi, A. Di Giovanni, R. Di Stefano, S. Diglio, A. Elykov, G. Eurin, A. D. Ferella, W. Fulgione, P. Gaemers, R. Gaior, M. Galloway, F. Gao, L. Grandi, C. Hasterok, C. Hils, K. Hiraide, L. Hoetzsch, J. Howlett, M. Iacovacci, Y. Itow, F. Joerg, N. Kato, S. Kazama, M. Kobayashi, G. Koltman, A. Kopec, H. Landsman, R. F. Lang, L. Levinson, Q. Lin, S. Lindemann, M. Lindner, F. Lombardi, J. Long, J. A. M. Lopes, E. López Fune, C. Macolino, J. Mahlstedt, A. Mancuso, L. Manenti, A. Manfredini, F. Marignetti, T. Marrodán Undagoitia, K. Martens, J. Masbou, D. Masson, S. Mastroianni, M. Messina, K. Miuchi, K. Mizukoshi, A. Molinario, K. Morå, S. Moriyama, Y. Mosbacher, M. Murra, J. Naganoma, K. Ni, U. Oberlack, K. Odgers, J. Palacio, B. Pelssers, R. Peres, J. Pienaar, V. Pizzella, G. Plante, J. Qin, H. Qiu, D. Ramírez García, S. Reichard, A. Rocchetti, N. Rupp, J. M. F. dos Santos, G. Sartorelli, N. Šarčević, M. Scheibelhut, J. Schreiner, D. Schulte, M. Schumann, L. Scotto Lavina, M. Selvi, F. Semeria, P. Shagin, E. Shockley, M. Silva, H. Simgen, A. Takeda, C. Therreau, D. Thers, F. Toschi, G. Trinchero, C. Tunnell, K. Valerius, M. Vargas, G. Volta, H. Wang, Y. Wei, C. Weinheimer, M. Weiss, D. Wenz, C. Wittweg, Z. Xu, M. Yamashita, J. Ye, G. Zavattini, Y. Zhang, T. Zhu, J. P. Zopounidis
XENONNT是一个暗物质直接探测实验,利用5.9吨装有仪器的液体氙,位于INFN大萨索国家实验室。在这项工作中,我们预测的实验背景和项目的灵敏度XENONNT弱相互作用大质量粒子(WIMPs)的检测。在所关心的能量区域中,对应于电子反冲和核反冲的(1,13)keV和(4,50)keV,在4 t基准质量中,预期的平均差分背景速率分别相当于$12.3 \pm 0.6$(keV t y)$^{-1}$和$(2.2\pm 0.5)\times 10^{-3}$(keV t y)$^{-1}$。我们使用轮廓构造方法计算统一的置信区间,以确保适当的覆盖率。随着20吨$\,$ y的曝光目标,预期的灵敏度自旋无关的WIMP-核子相互作用达到一个横截面的$1.4\times10^{-48}$厘米$^2$为50 GeV/c $^2$质量WIMP在90%的置信水平,超过一个数量级的当前最佳限制,由XENON 1 T设置。此外,我们表明,对于一个50 GeV/c的$^2$ WIMP的横截面以上$2.6\times10^{-48}$厘米$^2$($5.0\times10^{-48}$厘米$^2$)的中位数XENONNT发现的意义超过3 $σ$(5 $σ$)。对自旋相关的WIMP与中子(质子)耦合的预期灵敏度达到$2.2\times10^{-43}$ cm $^2$($6.0\times10^{-42}$ cm $^2$)。
英文摘要:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
Projected sensitivity to light WIMP-like particles of the BULLKID-DM experiment
University Grenoble Alpes, CNRS, Grenoble INP, Institut Néel(格勒诺布尔阿尔卑斯大学、法国国家科学研究中心、格勒诺布尔理工学院、内耳研究所);INFN Laboratori Nazionali del Gran Sasso(意大利国家核物理研究院大萨索国家实验室);Institute for Data Processing and Electronics, Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院数据处理与电子研究所);Gran Sasso Science Institute(大萨索科学研究所)
Projected Sensitivity of Paleo-Detectors to Dark Matter Effective Interactions with Nuclei
The University of Texas at Austin(德克萨斯大学奥斯汀分校);Stockholm University(斯德哥尔摩大学);KTH Royal Institute of Technology(皇家理工学院);University of North Florida(北佛罗里达大学);Jožef Stefan Institute(约瑟夫·斯蒂芬研究所)
Reconstructing Dark Matter Mass and Discriminating Standard and Non-Standard WIMP-Nucleus Interactions with Paleo-Detectors
The University of Texas at Austin(德克萨斯大学奥斯汀分校);Stockholm University(斯德哥尔摩大学);KTH Royal Institute of Technology(皇家理工学院);University of North Florida(北佛罗里达大学);Jožef Stefan Institute(约瑟夫斯蒂芬研究所)
In-situ Surface Contamination Removal and Cool-down Process of the DEAP-3600 Experiment
DEAP-3600实验是一个单相探测器,使用3600公斤液态氩在加拿大萨德伯里的SNOLAB寻找暗物质。地下对于100 GeV的WIMP质量,对自旋无关的WIMP-核子截面的投影灵敏度为$10^{-46}$ cm $^{2}$。一个关键的实验要求是减少任何可能模仿暗物质信号的背景源。本文将回顾如何通过使用表面修整机器人从探测器的最内部去除500微米的丙烯酸来原位减少放射性表面背景。此外,它将审查瞬态冷却过程的实验,必要的,以达到低温工作温度。
Enhanced Dark Matter Sensitivity using a Hybrid SiPM-SNSPD-Qubit Detector in Liquid Argon
Laboratory of Advanced Technologies and Instruments, IRSRA(IRSRA先进技术与仪器实验室);Institute of Theoretical Physics, INRC(INRC理论物理研究所);Energy Research Center, Al-Nahrain University(纳海林大学能源研究中心);Laboratory of Quantum Information, JINNR(JINNR量子信息实验室)
Detector Performance and Dark Matter Sensitivity of CYGNO with HFO-1234ze Gas Admixtures
Istituto Nazionale di Fisica Nucleare(意大利国家核物理研究所罗马第三分部);Sezione di Roma Tre(意大利国家核物理研究所大萨索国家实验室);Istituto Nazionale di Fisica Nucleare(意大利国家新能源与可再生能源研究中心弗拉斯卡蒂中心);Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所罗马分部);ENEA Centro Ricerche Frascati;Istituto Nazionale di Fisica Nucleare;Sezione di Roma