DMAPS Monopix developments in large and small electrode designs

Christian Bespin, Marlon Barbero, Pierre Barrillon, Ivan Berdalovic, Siddharth Bhat, Patrick Breugnon, Ivan Caicedo, Roberto Cardella, Zongde Chen, Yavuz Degerl… 展开作者

Christian Bespin, Marlon Barbero, Pierre Barrillon, Ivan Berdalovic, Siddharth Bhat, Patrick Breugnon, Ivan Caicedo, Roberto Cardella, Zongde Chen, Yavuz Degerli, Jochen Dingfelder, Leyre Flores Sanz de Acedo, Stephanie Godiot, Fabrice Guilloux, Toko Hirono, Tomasz Hemperek, Fabian Hügging, Hans Krüger, Thanushan Kugathasan, Cesar Augusto Marin Tobon, Konstantinos Moustakas, Patrick Pangaud, Heinz Pernegger, Francesco Piro, Petra Riedler, Alexandre Rozanov, Piotr Rymaszewski, Philippe Schwemling, Walter Snoeys, Maxence Vandenbroucke, Tianyang Wang, Norbert Wermes, Sinuo Zhang

摘要:

LF-Monopix 1和TJ-Monopix 1是分别采用150 nm LFoundry和180 nm TowerJazz CMOS技术的耗尽型单片有源像素传感器(DMAPS)。它们被设计用于高速率和高辐射环境,例如高亮度大型强子对撞机(HL-LHC)的ATLAS内部跟踪器。这两个芯片的读出使用列漏极读出架构。LF-Monopix 1采用大电荷收集电极的设计,其中读出电子器件放置在内部。通常,这在传感器中提供均匀的电场和短的漂移距离。TJ-Monopix 1采用了一个小的电荷收集电极,读出电子元件与电极和一个额外的n型植入物分离,以实现敏感体积的完全耗尽。这种方法提供低传感器电容,因此提供低噪声,并且通常以小像素尺寸实现。这两种探测器的特点是之前和之后的照射使用实验室测试和粒子束。

英文摘要:

LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows a design with large charge collection electrode where readout electronics are placed inside. Generally, this offers a homogeneous electrical field in the sensor and short drift distances. TJ-Monopix1 employs a small charge collection electrode with readout electronics separated from the electrode and an additional n-type implant to achieve full depletion of the sensitive volume. This approach offers a low sensor capacitance and therefore low noise and is typically implemented with small pixel size. Both detectors have been characterized before and after irradiation using lab tests and particle beams.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑