Cardiovascular diseases are one of the most severe causes of mortality, taking a heavy toll of lives annually throughout the world. The continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, bringing about several layers of complexities. This motivates us to develop a method to predict the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using photoplethysmogram (PPG) signals. In addition we explore the advantage of deep learning as it would free us from sticking to ideally shaped PPG signals only, by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present, PPG2ABP, a deep learning based method, that manages to predict the continuous ABP waveform from the input PPG signal, with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of DBP, MAP and SBP from the predicted ABP waveform outperforms the existing works under several metrics, despite that PPG2ABP is not explicitly trained to do so.
Self-Supervised Autoencoder Network for Robust Heart Rate Extraction from Noisy Photoplethysmogram: Applying Blind Source Separation to Biosignal Analysis
Mellowing Factory Co. Ltd.(梅洛灵工厂有限公司);Chungnam National University Hospital(全南国立大学医院);Department of Radiology, Seoul National University College of Medicine(首尔国立大学医学院放射科)
Healthcare Technology Innovation Centre (HTIC)(医疗技术创新中心);Indian Institute of Technology Madras(印度理工学院马德拉斯分校);Department of Electrical Engineering, Indian Institute of Technology Madras(印度理工学院马德拉斯分校电气工程系)
Photoplethysmogram (PPG) is increasingly used to provide monitoring of the cardiovascular system under ambulatory conditions. Wearable devices like smartwatches use PPG to allow long term unobtrusive monitoring of heart rate in free living conditions. PPG based heart rate measurement is unfortunately highly susceptible to motion artifacts, particularly when measured from the wrist. Traditional machine learning and deep learning approaches rely on tri-axial accelerometer data along with PPG to perform heart rate estimation. The conventional learning based approaches have not addressed the need …
Qatar University(卡塔尔大学);Universiti Kebangsaan Malaysia(马来西亚国立大学);BUET(孟加拉国工程技术大学)
Cardiovascular diseases are the most common causes of death around the world. To detect and treat heart-related diseases, continuous Blood Pressure (BP) monitoring along with many other parameters are required. Several invasive and non-invasive methods have been developed for this purpose. Most existing methods used in the hospitals for continuous monitoring of BP are invasive. On the contrary, cuff-based BP monitoring methods, which can predict Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), cannot be used for continuous monitoring. Several studies attempted to predict BP fr…
Indian Institute of Engineering Science and Technology, Shibpur(希布尔印度工程科学与技术学院);Hong Kong University of Science and Technology(香港科技大学)
Photoplethysmography (PPG) signal comprises physiological information related to cardiorespiratory health. However, while recording, these PPG signals are easily corrupted by motion artifacts and body movements, leading to noise enriched, poor quality signals. Therefore ensuring high-quality signals is necessary to extract cardiorespiratory information accurately. Although there exists several rule-based and Machine-Learning (ML) - based approaches for PPG signal quality estimation, those algorithms' efficacy is questionable. Thus, this work proposes a lightweight CNN architecture for signal q…
Deriving Health Metrics from the Photoplethysmogram: Benchmarks and Insights from MIMIC-III-Ext-PPG
AI4Health Department, Oldenburg University(AI4Health部门,旧恩斯特堡大学);Department of Data Science and AI, National Physical Laboratory(数据科学与人工智能系,国家物理实验室);School of Mathematics and Physics, University of Surrey(数学与物理学院,萨里大学);Department of Public Health and Primary Care, University of Cambridge(公共卫生与初级保健系,剑桥大学)
SSN College of Engineering(SSN工程学院);College of Engineering, Guindy(Guindy工程学院);Solarillion Foundation(Solarillion基金会)
Blood pressure (BP) is one of the most influential bio-markers for cardiovascular diseases and stroke; therefore, it needs to be regularly monitored to diagnose and prevent any advent of medical complications. Current cuffless approaches to continuous BP monitoring, though non-invasive and unobtrusive, involve explicit feature engineering surrounding fingertip Photoplethysmogram (PPG) signals. To circumvent this, we present an end-to-end deep learning solution, BP-Net, that uses PPG waveform to estimate Systolic BP (SBP), Mean Average Pressure (MAP), and Diastolic BP (DBP) through intermediate…
Infant Research Centre(婴儿研究中心);School of Computing(计算机学院);Dublin City University(都柏林城市大学);Department of Electrical Engineering(电气工程系);KU Leuven(鲁汶大学);Cork University Maternity Hospital(科克大学妇产医院);Insight SFI Research Centre(Insight SFI研究中心)
Ischemic heart disease is the highest cause of mortality globally each year. This not only puts a massive strain on the lives of those affected but also on the public healthcare systems. To understand the dynamics of the healthy and unhealthy heart doctors commonly use electrocardiogram (ECG) and blood pressure (BP) readings. These methods are often quite invasive, in particular when continuous arterial blood pressure (ABP) readings are taken and not to mention very costly. Using machine learning methods we seek to develop a framework that is capable of inferring ABP from a single optical phot…
North South University(北南大学);Qatar University(卡塔尔大学);Universiti Kebangsaan Malaysia(马来西亚国民大学)
Hypertension is a potentially unsafe health ailment, which can be indicated directly from the Blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based BP measurements are discrete and uncomfortable to the user. To address this need, a cuff-less, continuous and a non-invasive BP measurement system is proposed using Photoplethysmogram (PPG) signal and demographic features using machine learning (ML) algorithms. PPG signals were acquired from 219 subjects, which undergo pre-processing and feature extraction st…
Respiratory rate (RR) can be estimated from the photoplethysmogram (PPG) recorded by optical sensors in wearable devices. The fusion of estimates from different PPG features has lead to an increase in accuracy, but also reduced the numbers of available final estimates due to discarding of unreliable data. We propose a novel, tunable fusion algorithm using covariance intersection to estimate the RR from PPG (CIF). The algorithm is adaptive to the number of available feature estimates and takes each estimates' trustworthiness into account. In a benchmarking experiment using the CapnoBase dataset…
Real-Time Stress Detection via Photoplethysmogram Signals: Implementation of a Combined Continuous Wavelet Transform and Convolutional Neural Network on Resource-Constrained Microcontrollers
University of Tehran(德黑兰大学);Kettering University(凯特林大学)
Objectives: This study examines human Photoplethysmogram (PPG) along with Electrocardiogram (ECG) signals to study cardiac autonomic imbalance in epileptic seizures. The significance and the prevalence of changes in PPG morphological parameters have been investigated to find common patterns among subjects. Alterations in cardiovascular parameters measured by PPG/ECG signals are used to train a neural network based on LSTM for automatic seizure detection. Methods: Electroencephalogram (EEG), ECG, and PPG signals from 12 different subjects ( 8 males;4 females;age 34.3$\pm$ 13.8) were recorded in…
The paper proposes accurate Blood Pressure Monitoring (BPM) based on a single-site Photoplethysmographic (PPG) sensor and provides an energy-efficient solution on edge cuffless wearable devices. Continuous PPG signal preprocessed and used as input of the Artificial Neural Network (ANN), and outputs systolic BP (SBP), diastolic BP (DBP), and mean arterial BP (MAP) values for each heartbeat. The improvement of the BPM accuracy is obtained by removing outliers in the preprocessing step and the whole-based inputs compared to parameter-based inputs extracted from the PPG signal. Performance obtaine…
Healthcare Technology Innovation Centre (HTIC), IITM(医疗技术创新中心(HTIC),印度理工学院马德拉斯分校);Indian Institute of Technology Madras (IITM)(印度理工学院马德拉斯分校)
Respiratory ailments afflict a wide range of people and manifests itself through conditions like asthma and sleep apnea. Continuous monitoring of chronic respiratory ailments is seldom used outside the intensive care ward due to the large size and cost of the monitoring system. While Electrocardiogram (ECG) based respiration extraction is a validated approach, its adoption is limited by access to a suitable continuous ECG monitor. Recently, due to the widespread adoption of wearable smartwatches with in-built Photoplethysmogram (PPG) sensor, it is being considered as a viable candidate for con…
Ingenuity Labs Research Institute(Ingenuity Labs 研究院)
Electrocardiogram (ECG) is the electrical measurement of cardiac activity, whereas Photoplethysmogram (PPG) is the optical measurement of volumetric changes in blood circulation. While both signals are used for heart rate monitoring, from a medical perspective, ECG is more useful as it carries additional cardiac information. Despite many attempts toward incorporating ECG sensing in smartwatches or similar wearable devices for continuous and reliable cardiac monitoring, PPG sensors are the main feasible sensing solution available. In order to tackle this problem, we propose CardioGAN, an advers…
Goal: Although photoplethysmogram (PPG) and electrocardiogram (ECG) signals can be used to estimate blood pressure (BP) by extracting various features, the changes in morphological contours of both PPG and ECG signals due to various diseases of circulatory system and interaction of other physiological systems make the extraction of such features very difficult. Methods: In this work, we propose a waveform-based hierarchical Artificial Neural Network - Long Short Term Memory (ANN-LSTM) model for BP estimation. The model consists of two hierarchy levels, where the lower hierarchy level uses ANNs…
IIT Bhubaneswar(布巴内斯瓦尔印度理工学院);University of Auckland(奥克兰大学)
Biophysical signals such as Electrocardiogram (ECG) and Photoplethysmogram (PPG) are key to the sensing of vital parameters for wellbeing. Coincidentally, ECG and PPG are signals, which provide a "different window" into the same phenomena, namely the cardiac cycle. While they are used separately, there are no studies regarding the exact correction of the different ECG and PPG events. Such correlation would be helpful in many fronts such as sensor fusion for improved accuracy using cheaper sensors and attack detection and mitigation methods using multiple signals to enhance the robustness, for …
In this paper, the relation between electrocardiogram (ECG) and photoplethysmogram (PPG) signals is studied, and the waveform of ECG is inferred via the PPG signals. In order to address this inverse problem, a transform is proposed to map the discrete cosine transform (DCT) coefficients of each PPG cycle to those of the corresponding ECG cycle. The resulting DCT coefficients of the ECG cycle are inversely transformed to obtain the reconstructed ECG waveform. The proposed method is evaluated on a benchmark dataset of subjects with a variety of combinations of age and weight. Experimental result…
A Novel Transformer-Based Self-Supervised Learning Method to Enhance Photoplethysmogram Signal Artifact Detection
Biomedical Information Processing Lab, École de Technologie Supérieure, Montréal, Québec, Canada(生物医学信息处理实验室,蒙特利尔大学高等技术学院,加拿大魁北克省蒙特利尔);The Interdisciplinary Centre for Security, Reliability, and Trust (SnT), University of Luxembourg, Luxembourg(安全、可靠与信任跨学科中心(SnT),卢森堡大学,卢森堡);CHU Sainte-Justine Research Center, CHU Sainte-Justine Hospital, University of Montreal, Montréal, Québec, Canada(圣儒斯蒂娜研究中心,圣儒斯蒂娜医院,蒙特利尔大学,加拿大魁北克省蒙特利尔)
GRN-Transformer: Enhancing Motion Artifact Detection in PICU Photoplethysmogram Signals
École de Technologie Supérieure, University of Québec(魁北克大学高等技术学院);University of Luxembourg(卢森堡大学);CHU Sainte-Justine Research Center, CHU Sainte-Justine Hospital, University of Montreal(蒙特利尔大学圣朱斯蒂安医院研究中心)
Photoplethysmogram (PPG) signal-based blood pressure (BP) estimation is a promising candidate for modern BP measurements, as PPG signals can be easily obtained from wearable devices in a non-invasive manner, allowing quick BP measurement. However, the performance of existing machine learning-based BP measuring methods still fall behind some BP measurement guidelines and most of them provide only point estimates of systolic blood pressure (SBP) and diastolic blood pressure (DBP). In this paper, we present a cutting-edge method which is capable of continuously monitoring BP from the PPG signal a…
The presented study aims to estimate blood pressure (BP) using photoplethysmogram (PPG) signals while employing multiple machine learning models. The study proposes a novel algorithm for signal reconstruction, which utilizes the semi-classical signal analysis (SCSA) technique. The proposed algorithm optimises the semi-classical constant and eliminates the trade-off between complexity and accuracy in reconstruction. The reconstructed signals' spectral features are extracted and incorporated with clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed me…
With the ongoing heart problems of the population worldwide, the medical requirements of the people are expected to increase. Electrocardiogram (ECG) is one of the proven to capture the heart response signal to assess the electrical and muscular functions of the heart. The ECG setup is expensive and needs proper training, and of course, it is not instant. For fast, accurate heart parameter monitoring, scientists pay attention to the photoplethysmogram signal (PPG), based on the light intensity of a particular wavelength. Android smartphone with a good quality camera has come to ordinary people…
The 0-1 test distinguishes between regular and chaotic dynamics for a deterministic system using a time series. Here is presented how to use the test with biological signals. Between all the biological signals obtained as a times series, we present the results of applying the test and study with more details the photoplethysmogram (PPG) from different subjects; different biological signals of one subject are analyzed also with the test. PPG signal contains extensive physiological dynamics information; mainly used to heart rate monitoring and blood oxygen saturation. Based on its understandable…
This study explores extended feature space that is indicative of blood pressure (BP) changes for better estimation of continuous BP in an unobtrusive way. A total of 222 features were extracted from noninvasively acquired electrocardiogram (ECG) and photoplethysmogram (PPG) signals with the subject undergoing coronary angiography and/or percutaneous coronary intervention, during which intra-arterial BP was recorded simultaneously with the subject at rest and while administering drugs to induce BP variations. The association between the extracted features and the BP components, i.e. systolic BP…
Sleep is restoration process of the body. The efficiency of this restoration process is directly correlated to the amount of time spent at each sleep phase. Hence, automatic tracking of sleep via wearable devices has attracted both the researchers and industry. Current state-of-the-art sleep tracking solutions are memory and processing greedy and they require cloud or mobile phone connectivity. We propose a memory efficient sleep tracking architecture which can work in the embedded environment without needing any cloud or mobile phone connection. In this study, a novel architecture is proposed…
Obstructive Sleep Apnea (OSA) is a highly prevalent but inconspicuous disease that seriously jeopardizes the health of human beings. Polysomnography (PSG), the gold standard of detecting OSA, requires multiple specialized sensors for signal collection, hence patients have to physically visit hospitals and bear the costly treatment for a single detection. Recently, many single-sensor alternatives have been proposed to improve the cost efficiency and convenience. Among these methods, solutions based on RR-interval (i.e., the interval between two consecutive pulses) signals reach a satisfactory b…
This paper presents a novel approach based on pulse transit time (PTT) for the estimation of blood pressure (BP). In order to achieve this goal, a data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG) and photoplethysmogram (PPG). These two signals can derive PTT values. Meanwhile, a force-sensing resistor (FSR) is placed under the cuff of the BP reference device to mark the moments of measurements accurately via recording instantaneous cuff pressure. For deriving the PTT-BP models, a calibration procedure including a supervised physical exercise is conduc…
Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);University of Chinese Academy of Sciences(中国科学院大学);Hong Kong Polytechnic University(香港理工大学);Shenzhen Polytechnic University(深圳职业技术大学)