We present a novel diffractive imaging method that harnesses a low-resolution real-space image to guide the phase retrieval. A computational algorithm is developed to utilize such prior knowledge as a real-space constraint in the iterative phase retrieval procedure. Numerical simulations and proof-of-concept experiments are carried out, demonstrating our method's capability of reconstructing high-resolution details that are otherwise inaccessible with traditional phasing algorithms. With the present method, we formulate a conceptual design for the coherent imaging experiments at a next-generation X-ray light source.
Coherent diffractive imaging (CDI) is widely used to characterize structured samples from measurements of diffracting intensity patterns. We introduce a numerical framework to quantify the precision that can be achieved when estimating any given set of parameters characterizing the sample from measured data. The approach, based on the calculation of the Fisher information matrix, provides a clear benchmark to assess the performance of CDI methods. Moreover, by optimizing the Fisher information metric using deep learning optimization libraries, we demonstrate how to identify the optimal illumin…
We propose and experimentally demonstrate temporally low-coherent optical diffraction tomography (ODT) based on angle-scanning Mach-Zehnder interferometry. Using a digital micromirror device based on diffractive tilting, we successfully maintain full-field interference of incoherent light during every scan sequence. The ODT reconstruction principles for temporally incoherent illuminations are thoroughly reviewed and developed. Several limitations of incoherent illumination are also discussed, such as the nondispersive assumption, optical sectioning capacity, and illumination angle limitation. …
We describe a method of low-coherence interferometry based optical profilometry using standard light-emitting diode (LED) illumination and complementary metal-oxide-semiconductor (CMOS) image sensors. A line-field illumination strategy allows for the simultaneous measurement of many points in space. Micron scale accuracy and resolution are achieved and demonstrated using a variety of targets.
A method for realizing asymmetric (one-way) transmission of discretized light in modulated, linear and purely passive optical lattices is suggested, which exploits the idea of unidirectional coherent perfect absorption. The system consists of a linear photonic lattice of coupled resonators or waveguides, side coupled to a chain of lossy elements, in which light can avoid the occupation of the dissipative sites when propagating in one way, but not in the opposite one. Non-reciprocity requires modulation of the resonator/waveguide parameters, realizing a dissipative optical Aharonov-Bohm diode w…
Structured illumination microscopy (SIM) achieves doubled spatial resolution by exciting the specimen with a high-contrast, high-frequency sinusoidal pattern. Such an excitation pattern can be generated by interference between multiple laser beams, which are diffracted from a grating. In SIM, 2D imaging requires 9 patterns and 3D imaging requires 15 patterns. Compared to mechanical movement of gratings, opti-electro devices provide rapid switch of the excitation patterns, in which Digital Micro-mirror Device (DMD) is most common in industry. Here we model DMD as the blazed grating and report a…
One of the main advantages of reciprocal bianisotropic metasurfaces is their capability to produce asymmetric scattering depending from which side they are illuminated and on the handedness of circularly polarized illuminations. For most applications, these metasurfaces are designed for illumination by a single source at a time. The resulting bianisotropic metasurface has a specific and usually complex geometrical structure that ensures the expected scattering produced under various illuminations. Here we show that geometrical asymmetry of metasurfaces can be emulated by using non-bianisotropi…
We present a quantitative comparison between the high-pressure fuel spray images obtained experimentally using classical imaging with coherent and incoherent ultrafast illuminations recorded using a compatible CMOS camera. The ultrafast, incoherent illumination source was extracted from the supercontinuum generated by tightly focusing the femtosecond laser pulses in water. The average velocity maps computed using time-correlated image-pairs and spray edge complexity computed using the average curvature scale space maps are compared for the spray images obtained with the two illumination techni…
Optical diffraction tomography is an indispensable tool for studying objects in three-dimensions due to its ability to accurately reconstruct scattering objects. Until now this technique has been limited to coherent light because spatial phase information is required to solve the inverse scattering problem. We introduce a method that extends optical diffraction tomography to imaging spatially incoherent contrast mechanisms such as fluorescent emission. Our strategy mimics the coherent scattering process with two spatially coherent illumination beams. The interferometric illumination pattern en…
Recently an optical amplification process called the plasmon injection scheme was introduced as an effective solution to overcoming losses in metamaterials. Implementations with near-field imaging applications have indicated substantial performance enhancements even in the presence of noise. This powerful and versatile compensation technique, which has since been renamed to a more generalized active convolved illumination, offers new possibilities of improving the performance of many previously conceived metamaterial-based devices and conventional imaging systems. In this work, we present the …
Diffractive lenses fabricated by lithographic methods are one of the most popular image forming optics in the x-ray regime. Most commonly, binary diffractive optics, such as Fresnel zone plates are used due to their ability to focus at high resolution and to manipulate the x-ray wavefront. We report here a binary zone plate design strategy to form arbitrary illuminations for coherent multiplexing, structured illumination, and wavefront shaping experiments. Given a desired illumination, we adjust the duty cycle, harmonic order, and zone placement to vary both the amplitude and phase of the wave…
The wavefront is scrambled when coherent light propagates through a random scattering medium and which makes direct use of the conventional optical methods ineffective. In this paper, we propose and demonstrate a structured light illumination for imaging through an opaque scattering layer. Proposed technique is reference free and capable to recover the complex field from intensities of the speckle patterns. This is realized by making use of the phase-shifting in the structured light illumination and applying spatial averaging of the speckle pattern in the intensity correlation measurement. An …
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a non-imaging single-element detector. While non-imaging fluorescence detection offers some measure of scattering robustness, the rate at which dynamic specimens can be imaged is severely limited. Other fluorescent imaging techniques utilize imaging detection to enhance collection rates. A notabl…
Absorption of microwave by metallic conductors is exclusively inefficient, though being natively broadband, due to the huge impedance mismatch between metal and free space. Reducing the thickness to ultrathin conductive film may improve the absorbing efficiency, but is still bounded by a maximal 50% limit induced by the field continuity. Here, we show that broadband perfect (100%) absorption of microwave can be realized on a single layer of ultrathin conductive film when it is illuminated coherently by two oppositely incident beams. Such an effect of breaking the 50% limit maintains the intrin…
Diffraction tomography using coherent holographic imaging has been proposed by Emil Wolf in 1969 to extract 3D information from transparent, inhomogeneous objects. At the same time, the Wolf equations describe the propagation correlations associated with partially coherent fields. Combining these two concepts, here we present Wolf phase tomography (WPT), which is a method for performing diffraction tomography using partially coherent fields. The WPT reconstruction works in the direct space-time domain, without the need of Fourier transformation, and decouples the refractive index distribution …
We demonstrate a three-dimensional (3D) optical diffraction tomographic technique with optimal frequency combination (OFC-ODT) for the 3D quantitative phase imaging of unlabeled specimens. Three sets of through-focus intensity images are captured under an annular aperture and two circular apertures with different coherence parameters. The 3D phase optical transfer functions (POTF) corresponding to different illumination apertures are combined to obtain an optimally synthesized frequency response, achieving high-quality, low-noise 3D reconstructions with imaging resolution up to the incoherent …
Many imaging applications require increasingly bright illumination sources, motivating the replacement of conventional thermal light sources with light emitting diodes (LEDs), superluminescent diodes (SLDs) and lasers. Despite their brightness, lasers and SLDs are poorly suited for full-field imaging applications because their high spatial coherence leads to coherent artifacts known as speckle that corrupt image formation. We recently demonstrated that random lasers can be engineered to provide low spatial coherence. Here, we exploit the low spatial coherence of specifically-designed random la…
High-content biological microscopy targets high-resolution imaging across large fields-of-view (FOVs). Recent works have demonstrated that computational imaging can provide efficient solutions for high-content microscopy. Here, we use speckle structured illumination microscopy (SIM) as a robust and cost-effective solution for high-content fluorescence microscopy with simultaneous high-content quantitative phase (QP). This multi-modal compatibility is essential for studies requiring cross-correlative biological analysis. Our method uses laterally-translated Scotch tape to generate high-resoluti…
Developments in photonic chips have spurred photon based classical and quantum information processing, attributing to the high stability and scalability of integrated photonic devices [1, 2]. Optical nonlinearity [3] is indispensable in these complex photonic circuits, because it allows for classical and quantum light sources, all-optical switch, modulation, and non-reciprocity in ambient environments. It is commonly known that nonlinear interactions are often greatly enhanced in the microcavities [4]. However, the manifestations of coherent photon-photon interaction in a cavity, analogous to …
We present an optical Kerr effect based time-gate with the collinear incidence of the pump and probe beams at the Kerr medium, liquid carbon disulfide, for ballistic imaging of the high-pressure fuel sprays. The probe pulse used to illuminate the object under study is extracted from the supercontinuum generated by tightly focusing intense femtosecond laser pulses inside water, thereby destroying their coherence. The optical imaging spatial resolution and gate timings are investigated and compared with a similar setup without supercontinuum generation, where the probe is still coherent. And fin…
Coherent ptychographic imaging experiments often discard over 99.9 % of the flux from a light source to define the coherence of an illumination. Even when coherent flux is sufficient, the stability required during an exposure is another important limiting factor. Partial coherence analysis can considerably reduce these limitations. A partially coherent illumination can often be written as the superposition of a single coherent illumination convolved with a separable translational kernel. In this paper we propose the Gradient Decomposition of the Probe (GDP), a model that exploits translational…
We show that with spatially incoherent illumination, the point spread function width of an imaging interferometer like that used in full-field optical coherence tomography (FFOCT) is almost insensitive to aberrations that mostly induce a reduction of the signal level without broadening. This is demonstrated by comparison with traditional scanning OCT and wide-field OCT with spatially coherent illuminations. Theoretical analysis, numerical calculation as well as experimental results are provided to show this specific merit of incoherent illumination in full-field OCT. To the best of our knowled…
An optical transmitter irradiates a target region containing a bright thermal-noise bath in which a low-reflectivity object might be embedded. The light received from this region is used to decide whether the object is present or absent. The performance achieved using a coherent-state transmitter is compared with that of a quantum illumination transmitter, i.e., one that employs the signal beam obtained from spontaneous parametric downconversion (SPDC). By making the optimum joint measurement on the light received from the target region together with the retained SPDC idler beam, the quantum i…
In this work we propose and theoretically characterize optical isolators consisting of an all-dielectric and non-magnetic resonator featuring an intensity-dependent refractive index and a strong coherent field propagating in a single direction. Such devices can be straightforwardly realized in state-of-the-art integrated photonics platforms. The mechanism underlying optical isolation is based on the breaking of optical reciprocity induced by the asymmetric action of four-wave mixing processes coupling a strong propagating pump field with co-propagating signal/idler modes but not with reverse-p…
Coherent, purely-dispersive three-wave mixing systems in optics and superconducting microwave circuits can be operated as parametric amplifiers, generating from a pump wave at one frequency amplified signal and idler waves at lower frequencies. Here we demonstrate the reciprocal process using a Josephson amplifier in which coherently imposed signal and idler beams up-convert to the pump frequency. For signal and idler beams strong enough to significantly deplete the pump, we show that this reciprocal process ("coherent cancellation") leads to large, phase-sensitive modulation and even enhancem…
The formation of a stable magneto plasmonic dimer with THz resonances is theoretically studied for the principal directions of the system. Unlike a recent report, our work provides a complete description of the full photonic coupling for arbitrary magnetic fields as, for instance, unbalanced particle spins. As an illustration, we consider two small, n-doped InSb nanoparticles under illumination by two counter-propagating plane waves. Remarkably, when an external magnetic field exists, the symmetry in the system is broken, and a resonant radiation pressure for the dimer appears. Similarly, tuna…
In this paper we consider narrow band, active array imaging of weak localized scatterers when only the intensities are recorded at an array with N transducers. We consider that the medium is homogeneous and, hence, wave propagation is fully coherent. This work is an extension of our previous paper, where we showed that using linear combinations of intensity-only measurements imaging of localized scatterers can be carried out efficiently using MUSIC or sparsity promoting optimization. Here we show the same strategy can be accomplished with only 3N-2 illuminations, therefore reducing enormously …
This work introduces a novel reinterpretation of structured illumination (SI) microscopy for coherent imaging that allows three-dimensional imaging of complex refractive index (RI). To do so, we show that coherent SI is mathematically equivalent to a superposition of angled illuminations. It follows that raw acquisitions for standard SI-enhanced quantitative-phase images can be processed into complex electric-field maps describing sample diffraction under angled illuminations. Standard diffraction tomography (DT) computation can then be used to reconstruct the sample 3D RI distribution at sub-…
Because of the temporal incoherence of sunlight, solar cells efficiency should depend on the degree of coherence of the incident light. However, numerical computation methods, which are used to optimize these devices, fundamentally consider fully coherent light. Hereafter, we show that the incoherent efficiency of solar cells can be easily analytically calculated. The incoherent efficiency is simply derived from the coherent one thanks to a convolution product with a function characterizing the incoherent light. Our approach is neither heuristic nor empiric but is deduced from first-principle,…
Coherent diffraction imaging (CDI) is a promising imaging technique revealing most of the information from diffraction measurements. An ideal CDI should reconstruct complex-valued object from a single-shot far-field diffraction without any priori information about the target. To realize the ideal CDI, we propose a class of parameter-robust illumination pattern. A direct phase optimizing algorithm is also raised here to improve the performance of phase retrieval in strong noise. Experimental result demonstrates the efficiency of our scheme in practical noisy measurement for complex-valued targe…
Most applications of metasurfaces require excitation and control of both electric and magnetic surface currents. For such purpose, the metasurface must have a finite thickness to handle magnetic surface currents. For metasurface sheets of negligible thickness that offer only electric response, coherent illumination can compensate the need to create discontinuities of the tangential electric field component using magnetic surface currents. Most of known coherent metasurfaces are space-uniform and can control only plane-wave absorption and specular reflection. However, it is also known that peri…
For quantitative phase imaging (QPI) based on transport-of-intensity equation (TIE), partially coherent illumination provides speckle-free imaging, compatibility with brightfield microscopy, and transverse resolution beyond coherent diffraction limit. Unfortunately, in a conventional microscope with circular illumination aperture, partial coherence tends to diminish the phase contrast, exacerbating the inherent noise-to-resolution tradeoff in TIE imaging, resulting in strong low-frequency artifacts and compromised imaging resolution. Here, we demonstrate how these issues can be effectively add…
The transport-of-intensity equation (TIE) is a well-established non-interferometric phase retrieval approach, which enables quantitative phase imaging (QPI) of transparent sample simply by measuring the intensities at multiple axially displaced planes. Nevertheless, it still suffers from two fundamentally limitations. First, it is quite susceptible to low-frequency errors (such as \cloudy" artifacts), which results from the poor contrast of the phase transfer function (PTF) near the zero frequency. Second, the reconstructed phase tends to blur under spatially low-coherent illumination, especia…
A major impediment of using Coherent Anti-Stokes Raman Scattering to identify biological molecules is that the illumination levels required to produce a measurable signal often also produce significant nonresonant background from the medium, especially from water, that is not specific to the resonance being investigated. We present a method of using nonlinear interferometry to measure the temporal shape of the anti-Stokes signal to differentiate which components are resonant and nonresonant. This method is easily adaptable to most existing pulsed CARS illumination methods and should allow for …
Wavefront sensing with a thin diffuser has emerged as a potential low-cost alternative to a lenslet array for aberrometry. Diffuser wavefront sensors (DWS) have previously relied on tracking speckle displacement and consequently require coherent illumination. Here we show that displacement of caustic patterns can be tracked for estimating wavefront gradient, enabling the use of incoherent light sources and large dynamic-range wavefront measurements. We compare the precision of a DWS to a Shack-Hartmann wavefront sensor (SHWS) when using coherent, partially coherent, and incoherent illumination…
Achieving high spatial resolution is the goal of many imaging systems. Designing a high-resolution lens with diffraction-limited performance over a large field of view remains a difficult task in imaging system design. On the other hand, creating a complex speckle pattern with wavelength-limited spatial features is effortless and can be implemented via a simple random diffuser. With this observation and inspired by the concept of near-field ptychography, we report a new imaging modality, termed near-field Fourier ptychography, for tackling high-resolution imaging challenges in both microscopic…
We propose a collinear optical Kerr effect (OKE) based time-gate configuration with low coherence illumination source, derived from the supercontinuum (SC) generated by focusing the femtosecond laser pulses inside water. At first the spectral broadening in SC generation and corresponding changes in its coherence properties are studied and then a narrow band of wavelengths is extracted to use as the probe beam in the OKE-based time-gate configuration. The gate timings and spatial resolution of the time-gated images are also investigated. The low coherence of the probe ensures that the artifacts…
Speckle is the spatial fluctuation of irradiance seen when coherent light is reflected from a rough surface. It is due to light reflected from the surface's many nooks and crannies accumulating vastly-discrepant time delays, spanning much more than an optical period, en route to an observation point. Although speckle with continuous-wave (cw) illumination is well understood, the emerging interest in non-line-of-sight (NLoS) imaging using coherent light has created the need to understand the higher-order speckle that results from multiple rough-surface reflections, viz., speckled speckle and sp…
Quantitative phase microscopy (QPM) is often based on recording an object-reference interference pattern and its further phase demodulation. We propose Pseudo Hilbert Phase Microscopy (PHPM) where we combine pseudo thermal light source illumination and Hilbert spiral transform phase demodulation to achieve hybrid hardware-software-driven noise robustness and increase in resolution of single-shot coherent QPM. Those advantageous features stem from physically altering the laser spatial coherence and numerically restoring spectrally overlapped object spatial frequencies. Capabilities of the PHPM …
Phase-resolved wide-field CARS microscopy with speckle illumination
Aix Marseille University, CNRS, Centrale Med, Institut Fresnel(艾克斯-马赛大学、法国国家科学研究中心、中央理工-马赛学院、菲涅耳研究所);Institut Universitaire de France (IUF)(法兰西学院);Morgridge Institute for Research(莫格里奇研究所);XLIM, CNRS UMR 7252, Université de Limoges(XLIM实验室、法国国家科学研究中心UMR 7252、利摩日大学)
Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography
Centre National de la Recherche Scientifique (CNRS) UMR 7587, Institut Langevin. Paris Sciences et Lettres (PSL) University, Sorbonne Université (SU). École Supérieure de Physique et de Chimie Industrielles (ESPCI) Paris(法国国家科学研究中心(CNRS)UMR 7587,朗之万研究所。巴黎文理研究大学(PSL),索邦大学(SU)。巴黎高等物理化工国立学院(ESPCI))
Modern optical microscopy methods have been advanced to provide super resolution at high imaging speed, but not chirality discriminative. We recently proposed chiral structured-illumination microscopy (SIM) method to image chiral fluorescent domains at sub-wavelength resolution. Chiral SIM is suitable for imaging chiral domains at sub-wavelength resolution but loses the high spatial frequency of the achiral ones. In order to obtain the full picture of all fluorescent domains at sub-wavelength resolution, we propose an advanced version of chiral SIM, termed double SIM, which enables simultaneou…
Fourier ptychographic (FP) microscope is a coherent imaging method that can synthesize an image with a higher bandwidth using multiple low-bandwidth images captured at different spatial frequency regions. The method's demand for multiple images drives the need for a brighter illumination scheme and a high-frame-rate camera for a faster acquisition. We report the use of a guided laser beam as an illumination source for an FP microscope. It uses a mirror array and a 2-dimensional scanning Galvo mirror system to provide a sample with plane-wave illuminations at diverse incidence angles. The use o…
The complete characterization of spatial coherence is difficult because the mutual coherence function is a complex-valued function of four independent variables. This difficulty limits the ability of controlling and optimizing spatial coherence in a broad range of key applications. Here we propose a method for measuring the complete mutual coherence function, which does not require any prior knowledge and can be scaled to measure arbitrary coherence properties for any wavelength. Our method can also be used to retrieve objects illuminated by partially coherent beam with unknown coherence prope…