Energy resolution and linearity of XENON1T in the MeV energy range
E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauerme… 展开作者
E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino, M. Clark, D. Coderre, A. P. Colijn, J. Conrad, J. P. Cussonneau, M. P. Decowski, A. Depoian P. Di Gangi A. Di Giovanni R. Di Stefano, S. Diglio, A. Elykov, G. Eurin, A. D. Ferella, W. Fulgione, P. Gaemers, R. Gaior, A. Gallo Rosso, M. Galloway, F. Gao, M. Garbini, L. Grandi, C. Hasterok, C. Hils, K. Hiraide, L. Hoetzsch, E. Hogenbirk, J. Howlett, M. Iacovacci, Y. Itow, F. Joerg, N. Kato, S. Kazama, M. Kobayashi, G. Koltman, A. Kopec, H. Landsman, R. F. Lang, L. Levinson, Q. Lin, S. Lindemann, M. Lindner, F. Lombardi, J. A. M. Lopes, E. López Fune, C. Macolino, J. Mahlstedt, L. Manenti, A. Manfredini, F. Marignetti, T. Marrodán Undagoitia, K. Martens, J. Masbou, D. Masson, S. Mastroianni, M. Messina, K. Miuchi, A. Molinario, K. Morå, S. Moriyama, Y. Mosbacher, M. Murra, J. Naganoma, K. Ni, U. Oberlack, K. Odgers, J. Palacio, B. Pelssers, R. Peres, J. Pienaar, V. Pizzella, G. Plante J. Qin, H. Qiu, D. Ramírez García, S. Reichard, A. Rocchetti, N. Rupp, J. M. F. dos Santos, G. Sartorelli, N. Šarčević, M. Scheibelhut, S. Schindler, J. Schreiner, D. Schulte, M. Schumann, L. Scotto Lavina, M. Selvi, F. Semeria, P. Shagin, E. Shockley, M. Silva, H. Simgen, A. Takeda, C. Therreau, D. Thers, F. Toschi, G. Trinchero, C. Tunnell, M. Vargas, G. Volta, O. Wack, H. Wang, Y. Wei, C. Weinheimer, M. Weiss Xu, D. Wenz, C. Wittweg, J. Wulf, Z. Xu, M. Yamashita, J. Ye, G. Zavattini, Y. Zhang, T. Zhu, J. P. Zopounidis
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
Physics Prospects with MeV Neutrino-Argon Charged Current Interactions using Enhanced Photon Detection in Future LArTPCs
Stony Brook University, SUNY(石溪大学);Brookhaven National Laboratory(布鲁克海文国家实验室);Florida State University(佛罗里达州立大学);University of Antananarivo(塔那那利佛大学);Fermi National Accelerator Laboratory(费米国家加速器实验室)
SiPM non-linearity studies in beam tests with scintillating crystals
Tsung-Dao Lee Institute, Shanghai Jiao Tong University(上海交大李政道研究所);Key Laboratory for Particle Astrophysics and Cosmology (MOE), Shanghai Key Laboratory for Particle Physics and Cosmology (SKLPPC), Shanghai Jiao Tong University(上海交通大学粒子天体物理与宇宙学教育部重点实验室/上海粒子物理与宇宙学重点实验室);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学)
Performance of an LYSO-Based Active Converter for a Conversion Spectrometer aiming for 52.8 MeV photon detection in Future $μ^+ \to e^+ γ$ Search Experiments
Stable Charge Collection and Sub-45 ps Time Resolution in a 4H-SiC PIN Detector Irradiated With Low Fluence 16.5 MeV/u Ta Ions
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Qufu Normal University(曲阜师范大学);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);Liaoning University(辽宁大学)
Extreme Ultraviolet Time- and Angle-Resolved Photoemission Spectroscopy with 21.5 meV Resolution using High-Order Harmonic Generation from a Turn-Key Yb:KGW Amplifier
表征和控制量子材料的电子性质需要在动量空间的大区域上直接测量非平衡电子能带结构。在这里,我们展示了一个实验装置的时间和角度分辨的光电子能谱使用高次谐波探测脉冲产生的一个强大的,中等高功率(20 W)Yb:KGW放大器与可调重复频率在50和150 kHz之间。通过驱动高次谐波产生(HHG)的基本1025 nm的激光脉冲的二次谐波,我们表明,在21.8 eV的光子能量的单谐波探测脉冲可以有效地隔离,而不使用单色器。在50 kHz下,靶上光子通量可以达到5 x 10^10光子/秒,并且测量的时间分辨率为320 fs。Yb驱动的HHG源的相对较长的脉冲持续时间使我们能够达到21.5 meV的优异能量分辨率,这是通过在150 kHz的较高重复率下使用1.5 x 10^8光子/秒的低光子通量抑制空间电荷展宽来实现的。通过测量拓扑半金属ZrSiS和拓扑绝缘体Sb 2-xGdxTe 3的设置的能力证明。
Comparative study of YSO, GaGG, and BGO scintillators coupled to a SiPM array for gamma-ray spectroscopy
Institute of Radiation Problems- Ministry of Science and Education(辐射问题研究所);Department of Nuclear Research of IDDA(IDDA核研究系);Khazar University(哈萨尔大学);Joint Institute for Nuclear Research(联合核研究所);The Institute of Nuclear Physics(核物理研究所);Institute of Experimental and Applied Physics, CTU in Prague(布拉格捷克技术大学实验与应用物理研究所);Faculty of Electrical Engineering, UWB in Pilsen(比尔森西波希米亚大学电气工程学院)