arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2003.01485physics.ins-detnucl-ex
收藏

Performance recovery of long CsI(Tl) scintillator crystals with APD-based readout

P. Cabanelas, D. González, H. Alvarez-Pol, J. M. Boillos, E. Casarejos, J. Cederkall, D. Cortina, M. Feijoo, D. Galaviz, E. Galiana, R. Gernhäuser, P. Golubev, … 展开作者

P. Cabanelas, D. González, H. Alvarez-Pol, J. M. Boillos, E. Casarejos, J. Cederkall, D. Cortina, M. Feijoo, D. Galaviz, E. Galiana, R. Gernhäuser, P. Golubev, A. -L. Hartig, P. Klenze, A. Knyazev, T. Kröll, E. Nácher, J. Park, A. Perea, B. Pietras, L. Ponnath, H. -B. Rhee, J. L. Rodríguez-Sánchez, C. Suerder, O. Tengblad, P. Teubig

英文摘要:

CALIFA is the high efficiency and energy resolution calorimeter for the R3B experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the Phase-0 experiments at FAIR, between 2018 and 2020. It surrounds the reaction target in a segmented configuration with 2432 detection units made of long CsI(Tl) finger-shaped scintillator crystals. CALIFA has a 10 year intended operational lifetime as the R3B calorimeter, necessitating measures to be taken to ensure enduring performance. In this paper we present a systematic study of two groups of 6 different detection units of the CALIFA detector after more than four years of operation. The energy resolution and light output yield are evaluated under different conditions. Tests cover the aging of the first detector units assembled and investigates recovery procedures for degraded detection units. A possible reason for the observed degradation is given, pointing to the crystal-APD coupling.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑