Wireless power transmission (WPT) is a critical technology that provides a secure alternative mechanism for wireless power and communication with implantable medical devices. WPT approaches for implantable medical devices have been utilized based on applications. For instance, the inductive coupling tactic is mostly employed for transmission of energy to neuro-stimulators, and the ultrasonic method is used for deep-seated implants. This article provides a study concentrating on popular WPT techniques for implantable medical devices (IMDs) including inductive coupling, microwave, ultrasound, and hybrid WPT systems consisting of two approaches combined. Moreover, an overview of the major works is analyzed with a comparison of their major design elements, operating frequency, distance, efficiency, and harvested power.
Continuous health monitoring using wireless body area networks (WBANs) of wearable, epidermal and implantable medical devices is envisioned as a transformative approach to healthcare. Rapid advances in biomedical sensors, low-power electronics, and wireless communications have brought this vision to the verge of reality. However, key challenges still remain to be addressed. This paper surveys the current state-of-the-art in the area of wireless sensors for medical applications. Specifically, it focuses on presenting the recent advancements in wearable, epidermal and implantable technologies, a…
This paper proposes an ultrasonic backscatter communication (UsBC) system for passive implantable medical devices (IMDs) that can operate without batteries, enabling versatile revolutionary applications for future healthcare. The proposed UsBC system consists of a reader and a tag. The reader sends interrogation pulses to the tag. The tag backscatters the pulses based on the piezoelectric effect of a piezo transducer. We present several basic modulation schemes for UsBC by impedance matching of the piezo transducer. To mitigate the interference of other scatters in the human body, the tag tran…
In vivo wireless medical devices have the potential to play a vital role in future healthcare technologies by improving the quality of human life. In order to fully exploit the capabilities of such devices, it is necessary to characterize and model the in vivo wireless communication channel. Utilization of this model will have a significant role in improving the communication performance of embedded medical devices in terms of power, reliability and spectral efficiency. In this paper, the state of the art in this field is presented to provide a comprehensive understanding of current models. Su…
This paper presents a dual-factor authentication protocol and its low-power implementation for security of implantable medical devices (IMDs). The protocol incorporates traditional cryptographic first-factor authentication using Datagram Transport Layer Security - Pre-Shared Key (DTLS-PSK) followed by the user's touch-based voluntary second-factor authentication for enhanced security. With a low-power compact always-on wake-up timer and touch-based wake-up circuitry, our test chip consumes only 735 pW idle state power at 20.15 Hz and 2.5 V. The hardware accelerated dual-factor authentication u…
Wireless power transfer using inductive coupling is commonly used for medical implantable devices. The design of the secondary coil on the implantable device is important as it will affect the power transfer efficiency, the size of the implant, and also the data transmission between the implant and the in-vitro controller. In this paper, we present a design of the secondary coil on a polyimide-based flexible substrate to achieve high power transfer efficiency. Load shift keying modulation is used for the data communication between the primary and secondary coils. A thorough analysis is done fo…
A button sensor antenna for wireless medical body area networks (WMBAN) is presented, which works through the IEEE 802.11b/g/n standard. Due to strong interaction between the sensor antenna and the body, an innovative robust system is designed with a small footprint that can serve on- and off-body healthcare applications. The measured and simulated results are in good agreement. The design offers a wide range of omnidirectional radiation patterns in free space, with a reflection coefficient (S11) of -29.30 (-30.97) dB in the lower (upper) bands. S11 reaches up to -23.07 (-27.07) dB and -30.76 …
Wireless implanted medical devices (IMDs) provide ease and comfort to an increasing number of patients and physicians. Currently, radiofrequency electromagnetic waves are the most commonly used method for communicating wirelessly with IMDs. However, due to the restrictions on the available bandwidth and the employable power, data rates of RF-based IMDs are limited to 267 kbps. Considering standard definition video streaming requiring 1.2 mbps and high definition requiring 3 mbps bitrates, it is not possible to use such devices for high data rate communication applications such as video streami…
Epilepsy is one of the most common neurological disorders affecting up to 1% of the world's population and approximately 2.5 million people in the United States. Seizures in more than 30% of epilepsy patients are refractory to anti-epileptic drugs. An important biomedical research effort is focused on the development of an energy efficient implantable device for the real-time control of seizures. In this paper we propose an Internet of Medical Things (IoMT) based automated seizure detection and drug delivery system (DDS) for the control of seizures. The proposed system will detect seizures and…
The discrete Hartley transform (DHT) is a useful tool for medical image coding. The three-dimensional DHT (3D DHT) can be employed to compress medical image data, such as magnetic resonance and X-ray angiography. However, the computation of the 3D DHT involves several multiplications by irrational quantities, which require floating-point arithmetic and inherent truncation errors. In recent years, a significant progress in wireless and implantable biomedical devices has been achieved. Such devices present critical power and hardware limitations. The multiplication operation demands higher hardw…
CommScope(康普公司);University of Glasgow(格拉斯哥大学);Sonova AG(索诺瓦公司);University of Manchester(曼彻斯特大学);University of Edinburgh(爱丁堡大学);Edinburgh Napier University(爱丁堡纳皮尔大学)
A flexible meander line monopole antenna (MMA) is presented in this paper. The antenna can be worn for on-and off-body applications. The overall dimension of the MMA is 37 mm x 50 mm x2.37 mm3. The MMA was manufactured and measured, and the results matched with simulation results. The MMA design shows a bandwidth of up to 1282.4 (450.5) MHz and provides gains of 3.03 (4.85) dBi in the lower and upper operating bands, respectively, showing omnidirectional radiation patterns in free space. While worn on the chest or arm, bandwidths as high as 688.9 (500.9) MHz and 1261.7 (524.2) MHz, and the gai…
Rapid evolution of wireless medical devices and network technologies has fostered the growth of remote monitoring systems. Such new technologies enable monitoring patients' medical records anytime and anywhere without limiting patients' activities. However, critical challenges have emerged with remote monitoring systems due to the enormous amount of generated data that need to be efficiently processed and wirelessly transmitted to the service providers in time. Thus, in this paper, we leverage full-duplex capabilities for fast transmission, while tackling the trade-off between Quality of Servi…
It has become very essential to address the limited spectrum capacity and their efficient utilization to support the increasing number of Internet of Things devices. When it comes to medical infrastructure, it becomes very imperative for medical devices to communicate with the base station. In such situations, communication over the wireless medium must provide optimized throughput (data rate) with effectual energy usage, which will ensure precise medical feedback by the responsible staff. Taking into account, it is necessary to operate wireless communication precisely at a higher frequency wi…
Circadian and other physiological rhythms play a key role in both normal homeostasis and disease processes. Such is the case of circadian and infradian seizure patterns observed in epilepsy. In this paper we explore a new implantable stimulator that implements chronotherapy as a feedforward input to supplement both open-loop and closed-loop methods. This integrated algorithm allows for stimulation to be adjusted to the ultradian, circadian and infradian patterns observed in patients through slowly-varying temporal adjustments of stimulation and algorithm sub-components, while also enabling ada…
There has been a continuing demand for improving the accuracy and ease of use of medical devices used on or around the human body. Communication is critical to medical applications, and wireless body area networks (WBANs) have the potential to revolutionize diagnosis. Despite its importance, WBAN technology is still in its infancy and requires much research. We consider body channel communication (BCC), which uses the whole body as well as the skin as a medium for communication. BCC is sensitive to the body's natural circulation and movement, which requires a noncoherent model for wireless com…