A crucial test for astronomical spectrograph calibration with frequency combs
Rafael A. Probst, Dinko Milaković, Borja Toledo-Padrón, Gaspare Lo Curto, Gerardo Avila, Anna Brucalassi, Bruno L. Canto Martins, Izan de Castro Leão, Massimili… 展开作者
Rafael A. Probst, Dinko Milaković, Borja Toledo-Padrón, Gaspare Lo Curto, Gerardo Avila, Anna Brucalassi, Bruno L. Canto Martins, Izan de Castro Leão, Massimiliano Esposito, Jonay I. González Hernández, Frank Grupp, Theodor W. Hänsch, Hanna Kellermann, Florian Kerber, Olaf Mandel, Antonio Manescau, Eszter Pozna, Rafael Rebolo, José Renan de Medeiros, Tilo Steinmetz, Alejandro Suárez Mascareño, Thomas Udem, Josefina Urrutia, Yuanjie Wu, Luca Pasquini, Ronald Holzwarth
Laser frequency combs (LFCs) are well on their way to becoming the next-generation calibration sources for precision astronomical spectroscopy. This development is considered key in the hunt for low-mass rocky exoplanets around solar-type stars whose discovery with the radial-velocity method requires cm/s Doppler precision. In order to prove such precise calibration with an LFC, it must be compared to another calibrator of at least the same precision. Being the best available spectrograph calibrator, this means comparing it to a second - fully independent - LFC. This test had long been pending, but our installation of two LFCs at the ultra-stable spectrograph HARPS presented the so far unique opportunity for simultaneous calibrations with two separate LFCs. Although limited in time, the test results confirm the 1 cm/s stability that has long been anticipated by the astronomical community.
We present a new solution for the dispersive element in astronomical spectrographs, which in many cases can provide an upgrade path to enhance the spectral resolution of existing moderate-resolution reflection-grating spectrographs. We demonstrate that in the case of LRIS-R at the Keck 1 Telescope a spectral resolution of 18,000 can be achieved with reasonable throughput under good seeing conditions.
Focal ratio degradation (FRD), the increase of light's focal ratio between the input into an optical fiber and the output, is important to characterize for astronomical spectrographs due to its effects on throughput and the point spread function. However, while FRD is a function of many fiber properties such as stresses, microbending, and surface imperfections, angular misalignments between the incoming light and the face of the fiber also affect the light profile and complicate this measurement. A compact experimental setup and a model separating FRD from angular misalignment was applied to a…
Precise wavelength calibration is a critical issue for high-resolution spectroscopic observations. The ideal calibration source should be able to provide a very stable and dense grid of evenly distributed spectral lines of constant intensity. A new method which satisfies all mentioned conditions has been developed by our group. The approach is to actively measure the exact position of a single spectral line of a Fabry-Perot etalon with very high precision with a wavelength-tuneable laser and compare it to an extremely stable wavelength standard. The ideal choice of standard is the D2 absorptio…
The Gemini Remote Access to CFHT ESPaDONS Spectrograph has achieved first light of its experimental phase in May 2014. It successfully collected light from the Gemini North telescope and sent it through two 270 m optical fibers to the the ESPaDOnS spectrograph at CFHT to deliver high-resolution spectroscopy across the optical region. The fibers gave an average focal ratio degradation of 14% on sky, and a maximum transmittance of 85% at 800nm. GRACES achieved delivering spectra with a resolution power of R = 40,000 and R = 66,000 between 400 and 1,000 nm. It has a ~8% throughput and is sensitiv…
Astronomical instrumentation is most of the time faced with challenging requirements in terms of sensitivity, stability, complexity, etc., and therefore leads to high performance developments that at first sight appear to be suitable only for the specific design application at the telescope. However, their usefulness in other disciplines and for other applications is not excluded. The ERA2 facility is a lab demonstrator, based on a high-performance astronomical spectrograph, which is intended to explore the innovation potential of fiber-coupled multi-channel spectroscopy for spatially resolved…
In astronomical spectroscopy, optical fibres are abundantly used for multiplexing and decoupling the spectrograph from the telescope to provide stability in a controlled environment. However, fibres are less than perfect optical components and introduce complex effects that diminish the overall throughput, efficiency, and stability of the instrument. We present a novel numerical field propagation model that emulates the effects of modal noise, scrambling, and focal ratio degradation with a rigorous treatment of wave optics. We demonstrate that the simulation of the near- and far-field output o…
We demonstrate for the first time an efficient, photonic-based astronomical spectrograph on the 8-m Subaru Telescope. An extreme adaptive optics system is combined with pupil apodiziation optics to efficiently inject light directly into a single-mode fiber, which feeds a compact cross-dispersed spectrograph based on array waveguide grating technology. The instrument currently offers a throughput of 5% from sky-to-detector which we outline could easily be upgraded to ~13% (assuming a coupling efficiency of 50%). The isolated spectrograph throughput from the single-mode fiber to detector was 42%…
We present results from the first on-sky demonstration of a prototype astronomical integrated photonic spectrograph (IPS) using the Anglo-Australian Telescope near-infrared imaging spectrometer (IRIS2) at Siding Spring Observatory to observe atmospheric molecular OH emission lines. We have succeeded in detecting upwards of 27 lines, and demonstrated the practicality of the IPS device for astronomy. Furthermore, we present a laboratory characterization of the device, which is a modified version of a commercial arrayed-waveguide grating multiplexer. We measure the spectral resolution full-width-…
Characterization and on-sky testing of photonic, AWG-based astronomical spectrographs
Université Côte d’Azur, Observatoire de la Côte d’Azur, CNRS, Laboratoire Lagrange(蔚蓝海岸大学,蔚蓝海岸天文台,法国国家科学研究中心,拉格朗日实验室);California Institute of Technology(加州理工学院);University of California, Los Angeles (UCLA)(加州大学洛杉矶分校);Université Grenoble Alpes, CNRS, IPAG(格勒诺布尔阿尔卑斯大学,法国国家科学研究中心,天体物理学与行星学研究所);Aix Marseille Université, CNRS, LAM (Laboratoire d’Astrophysique de Marseille) UMR 7326(艾克斯-马赛大学,法国国家科学研究中心,马赛天体物理实验室)
Validation and extension of the PAWS Zemax model as a first step in the development of a Compact Arrayed Waveguide Stacked Multi-Object Spectrograph (CAWSMOS)
Leibniz Institut für Astrophysik, Potsdam, Germany(波茨坦莱布尼茨天体物理研究所);Leibniz Institute for High Performance Microelectronics, Frankfurt (Oder), Germany(法兰克福(奥得河)莱布尼茨高性能微电子研究所);University of Potsdam, Potsdam, Germany(波茨坦大学)
Raman scattering enables unforeseen uses for the laser guide-star system of the Very Large Telescope. Here, we present the observation of one up-link sodium laser beam acquired with the ESPRESSO spectrograph at a resolution $λ/Δλ\sim 140'000$. In 900s on-source, we detect the pure rotational Raman lines of $^{16}$O$_2$, $^{14}$N$_2$, and $^{14}$N$^{15}$N (tentatively) up to rotational quantum numbers $J$ of 27, 24, and 9, respectively. We detect the $^{16}$O$_2$ fine-structure lines induced by the interaction of the electronic spin \textbf{S} and end-over-end rotational angular momentum \textb…
With the aim of utilizing arrayed waveguide gratings for multi-object spectroscopy in the field of astronomy, we outline several ways in which standard telecommunications grade chips should be modified. In particular, by removing the parabolic-horn taper or multimode interference coupler, and injecting with an optical fiber directly, the resolving power was increased threefold from 2400 \pm 200 (spectral resolution of 0.63 \pm 0.2 nm) to 7000 \pm 700 (0.22 \pm 0.02 nm) while attaining a throughput of 77 \pm 5%. More importantly, the removal of the taper enabled simultaneous off-axis injection …
The Xinglong 2.16-m reflector is the first 2-meter class astronomical telescope in China. It was jointly designed and built by the Nanjing Astronomical Instruments Factory (NAIF), Beijing Astronomical Observatory (now National Astronomical Observatories, Chinese Academy of Sciences, NAOC) and Institute of Automation, Chinese Academy of Sciences in 1989. It is Ritchey-Chrétien (R-C) reflector on an English equatorial mount and the effective aperture is 2.16 meters. It had been the largest optical telescope in China for $\sim18$ years until the Guoshoujing Telescope (also called Large Sky Area M…
In this paper, we are going to introduce the Kottamia Astronomical Observatory, KAO, to the astronomical community. The current status of the telescope together with the available instrumentations is described. An upgrade stage including a new optical system and a computer controlling of both the telescope and dome are achieved. The specifications of a set of CCD cameras for direct imaging and spectroscopy are given. A grating spectrograph is recently gifted to KAO from Okayama Astrophysical Observatory, OAO, of the National Astronomical Observatories in Japan. This spectrograph is successfull…
CubeSats are routinely used for low-cost photometry from space. Space-borne spectroscopy, however, is still the exclusive domain of much larger platforms. Key astrophysical questions in e.g. stellar physics and exoplanet research require uninterrupted spectral monitoring from space over weeks or months. Such monitoring of individual sources is unfortunately not affordable with these large platforms. With CUBESPEC we plan to offer the astronomical community a low-cost CubeSat solution for near-UV/optical/near-IR spectroscopy that enables this type of observations. CUBESPEC is a generic spectrog…
Astrophotonics is the application of photonic technologies to channel, manipulate, and disperse light from one or more telescopes to achieve scientific objectives in astronomy in an efficient and cost-effective way. Utilizing photonic advantage for astronomical spectroscopy is a promising approach to miniaturizing the next generation of spectrometers for large telescopes. It can be primarily attained by leveraging the two-dimensional nature of photonic structures on a chip or a set of fibers, thus reducing the size of spectroscopic instrumentation to a few centimeters and the weight to a few h…
Spectroscopy is one of the most important tools that an astronomer has for studying the universe. This chapter begins by discussing the basics, including the different types of optical spectrographs, with extension to the ultraviolet and the near-infrared. Emphasis is given to the fundamentals of how spectrographs are used, and the trade-offs involved in designing an observational experiment. It then covers observing and reduction techniques, noting that some of the standard practices of flat-fielding often actually degrade the quality of the data rather than improve it. Although the focus is …
Thorium hollow cathode lamps (HCLs) are used as frequency calibrators for many high resolution astronomical spectrographs, some of which aim for Doppler precision at the 1 m/s level. We aim to determine the most suitable combination of elements (Th or U, Ar or Ne) for wavelength calibration of astronomical spectrographs, to characterize differences between similar HCLs, and to provide a new U line-list. We record high resolution spectra of different HCLs using a Fourier transform spectrograph: (i) U-Ne, U-Ar, Th-Ne, and Th-Ar lamps in the spectral range from 500 to 1000 nm and U-Ne and U-Ar fr…
A photonic spectrograph can be much smaller than a conventional spectrograph with the same resolving power. Individual devices can be integrated with optical fibres to improve the multiplex gain in astronomical spectroscopy. Although experimental devices have been tested, the parameter space where integrated photonic spectrographs give a significant advantage over traditional methods has not been defined. This paper gives an overview of the theory with verification by direct simulation using Fresnel propagation and quantifies the benefit for representative spectroscopic capabilities. We thereb…
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomic…
Differential atmospheric dispersion is a wavelength-dependent effect introduced by the atmosphere. It is one of the instrumental errors that can affect the position of the target as perceived on the sky and its flux distribution. This effect will affect the results of astronomical observations if not corrected by an atmospheric dispersion corrector (ADC). In high-resolution spectrographs, in order to reach a radial velocity (RV) precision of 10 cm/s, an ADC is expected to return residuals at only a few tens of milli-arcseconds (mas). In fact, current state-of-the-art spectrographs conservative…
Adaptive optics (AO) have been used to correct wavefronts to achieve diffraction limited point spread functions in a broad range of optical applications, prominently ground-based astronomical telescopes operating in near infra-red. While most AO systems cannot provide diffraction-limited performance in the optical passband (400 nm - 900 nm), AO can improve image concentration, as well as both near and far field image stability, within an AO-fed spectrograph. Enhanced near and far field stability increase wavelength-scale stability in high dispersion spectrographs. In this work, we describe det…
The space ultraviolet (UV) is a critical astronomical observing window, where a multitude of atomic, ionic, and molecular signatures provide crucial insight into planetary, interstellar, stellar, intergalactic, and extragalactic objects. The next generation of large space telescopes require highly sensitive, moderate-to-high resolution UV spectrograph. However, sensitive observations in the UV are difficult, as UV optical performance and imaging efficiencies have lagged behind counterparts in the visible and infrared regimes. This has historically resulted in simple, low-bounce instruments to …
ASTRONIRCAM is a cryogenic-cooled slit spectrograph for the spectral range 1-2.5 mkm installed at the Nasmyth focus of the 2.5-meter telescope of the Caucasian observatory of Sternberg Astronomical Institute of Lomonosov Moscow State University. The instrument is equipped with the HAWAII-2RG 2048x2048 HgCdTe array. Grisms are used as dispersive elements. In the photometric mode ASTRONIRCAM allows for extended astronomical object imaging in the field of view of 4.6x4.6 arc minutes with the 0.269 arcsec/pixel scale in standard photometric bands J, H, K and Ks as well as in narrow-band filters CH…
Technological advancement has led to improvement in the design capabilities of astronomical spectrographs, allowing for high precision spectroscopy, thereby expanding the realms of observational astronomy. High-resolution spectrographs use Echelle grating that operates in higher orders, giving more detailed spectra. Often, curvature and tilted lines are observed in the spectra, arising due to the design trade-offs of the respective spectrographs. Removal of these artifacts can help avoid wrong flux calculation and line centroid position misinterpretation, which can aid in a better prediction o…
Accurate wavelength calibration is an important factor for any measurement with high resolution spectrographs. Stellar spectrum comprises of discrete absorption or emission lines whose position is precisely determined by calibrating the spectrograph using known reference lines generated from laboratory sources. For the spectrograph to measure small variations in Doppler shift, the wavelength calibration must be sufficiently stable during observation time. Instrument instability, mainly due to environmental factors like temperature and pressure variations, limitations of traditional calibration…
We present a modelling scheme that predicts the centroids of spectral line features for a high resolution Echelle spectrograph to a high accuracy. Towards this, a computing scheme is used, whereby any astronomical spectrograph can be modelled and controlled without recourse to a ray tracing program. The computations are based on paraxial ray trace and exact corrections added for certain surface types and Buchdahl aberration coefficients for complex modules. The resultant chain of paraxial ray traces and corrections for all relevant components is used to calculate the location of any spectral l…
We discuss the laser frequency comb as a near infrared astronomical wavelength reference, and describe progress towards a near infrared laser frequency comb at the National Institute of Standards and Technology and at the University of Colorado where we are operating a laser frequency comb suitable for use with a high resolution H band astronomical spectrograph.
Radial velocity (RV) surveys supported by high precision wavelength references (notably ThAr lamps and I2 cells) have successfully identified hundreds of exoplanets; however, as the search for exoplanets moves to cooler, lower mass stars, the optimum wave band for observation for these objects moves into the near infrared (NIR) and new wavelength standards are required. To address this need we are following up our successful deployment of an H band(1.45-1.7μm) laser frequency comb based wavelength reference with a comb working in the Y and J bands (0.98-1.3μm). This comb will be optimized for …
We present the data reduction pipeline, MEAD, for Arizona Lenslets for Exoplanet Spectroscopy (ALES), the first thermal infrared integral field spectrograph designed for high-contrast imaging. ALES is an upgrade of LMIRCam, the $1-5\,μ$m imaging camera for the Large Binocular Telescope, capable of observing astronomical objects in the thermal infrared ($3-5\,μ$m) to produce simultaneous spatial and spectral data cubes. The pipeline is currently designed to perform $L$-band ($2.8-4.2\,μ$m) data cube reconstruction, relying on methods used extensively by current near-infrared integral field spec…
The multi-object spectrograph (MOS) has been the benchmark for the current generation of astronomical spectrographs, valued for its ability to acquire the spectra of hundreds of objects simultaneously. In the last two decades, the digital micromirror device (DMD) has shown potential in becoming the central component of the MOS, being used as a programmable slit array. We have designed a seeing-limited DMD-based MOS covering a spectral range of 0.4 to 0.7 $μ$m, with a field of view (FOV) of $10.5^\prime \times 13.98^\prime$ and a spectral resolution of $R\sim1000$. This DMD-MOS employs all-sphe…
The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its dispersing element. The instrument uti…
We investigate a new scheme for astronomical spectrograph calibration using the laser frequency comb at the Solar Vacuum Tower Telescope on Tenerife. Our concept is based upon a single-mode fiber channel, that simultaneously feeds the spectrograph with comb light and sunlight. This yields nearly perfect spatial mode matching between the two sources. In combination with the absolute calibration provided by the frequency comb, this method enables extremely robust and accurate spectroscopic measurements. The performance of this scheme is compared to a sequence of alternating comb and sunlight, an…
Integrated photonic spectrographs offer an avenue to extreme miniaturization of astronomical instruments, which would greatly benefit extremely large telescopes and future space missions. These devices first require optimization for astronomical applications, which includes design, fabrication and field-testing. Given the high costs of photonic fabrication, Multi-Project Wafer (MPW) SiN offerings, where a user purchases a portion of a wafer, provide a convenient and affordable avenue to develop this technology. In this work we study the potential of two commonly used SiN waveguide geometries b…
We present the Spectroscopic Classification of Astronomical Transients (SCAT) survey, which is dedicated to spectrophotometric observations of transient objects such as supernovae and tidal disruption events. SCAT uses the SuperNova Integral-Field Spectrograph (SNIFS) on the University of Hawai'i 2.2-meter (UH2.2m) telescope. SNIFS was designed specifically for accurate transient spectrophotometry, including absolute flux calibration and host-galaxy removal. We describe the data reduction and calibration pipeline including spectral extraction, telluric correction, atmospheric characterization,…
Detection of weak radial velocity shifts of host stars induced by orbiting planets is an important technique for discovering and characterizing planets beyond our solar system. Optical frequency combs enable calibration of stellar radial velocity shifts at levels required for detection of Earth analogs. A new chip-based device, the Kerr soliton microcomb, has properties ideal for ubiquitous application outside the lab and even in future space-borne instruments. Moreover, microcomb spectra are ideally suited for astronomical spectrograph calibration and eliminate filtering steps required by con…
We present a technique to synthesise telluric absorption and emission features both for in-situ wavelength calibration and for their removal from astronomical spectra. While the presented technique is applicable for a wide variety of optical and infrared spectra, we concentrate in this paper on selected high-resolution near-infrared spectra obtained with the CRIRES spectrograph to demonstrate its performance and limitation. We find that synthetic spectra reproduce telluric absorption features to about 2%, even close to saturated line cores. Thus, synthetic telluric spectra could be used to rep…
A wavelength calibration system based on a laser frequency comb (LFC) was developed in a co-operation between the Kiepenheuer-Institut für Sonnenphysik, Freiburg, Germany and the Max-Planck-Institut für Quantenoptik, Garching, Germany for permanent installation at the German Vacuum Tower Telescope (VTT) on Tenerife, Canary Islands. The system was installed successfully in October 2011. By simultaneously recording the spectra from the Sun and the LFC, for each exposure a calibration curve can be derived from the known frequencies of the comb modes that is suitable for absolute calibration at th…
Over the past decades hollow-cathode lamps have been calibration standards for spectroscopic measurements. Advancing to cm/s radial velocity precisions with the next generation of instruments requires more suitable calibration sources with more lines and less dynamic range problems. Fabry-Perot interferometers provide a regular and dense grid of lines and homogeneous amplitudes making them good candidates for next generation calibrators. We investigate the usefulness of Fabry-Perot etalons in wavelength calibration, present an algorithm to incorporate the etalon spectrum in the wavelength solu…
We propose a dual cavity Fabry-Perot interferometer as a wavelength calibrator and a stability tracking device for astronomical spectrograph. The FPI consists of two adjoining cavities engraved on a low expansion monoblock spacer. A low-finesse astro-cavity is intended for generating a uniform grid of reference lines to calibrate the spectrograph and a high-finesse lock-cavity is meant for tracking the stability of the reference lines using optical frequency standards. The differential length changes in two cavities due to temperature and vibration perturbations are quantitatively analyzed usi…
The study of Earth-mass extrasolar planets via the radial-velocity technique and the measurement of the potential cosmological variability of fundamental constants call for very-high-precision spectroscopy at the level of $\updeltaλ/λ<10^{-9}$. Wavelength accuracy is obtained by providing two fundamental ingredients: 1) an absolute and information-rich wavelength source and 2) the ability of the spectrograph and its data reduction of transferring the reference scale (wavelengths) to a measurement scale (detector pixels) in a repeatable manner. The goal of this work is to improve the wavelength…
We describe and characterize a 25 GHz laser frequency comb based on a cavity-filtered erbium fiber mode-locked laser. The comb provides a uniform array of optical frequencies spanning 1450 nm to 1700 nm, and is stabilized by use of a global positioning system referenced atomic clock. This comb was deployed at the 9.2 m Hobby-Eberly telescope at the McDonald Observatory where it was used as a radial velocity calibration source for the fiber-fed Pathfinder near-infrared spectrograph. Stellar targets were observed in three echelle orders over four nights, and radial velocity precision of \sim10 m…
Modal noise in optical fibers imposes limits on the signal to noise and velocity precision achievable with the next generation of astronomical spectrographs. This is an increasingly pressing problem for precision radial velocity (RV) spectrographs in the near-infrared (NIR) and optical that require both high stability of the observed line profiles and high signal to noise. Many of these spectrographs plan to use highly coherent emission line calibration sources like laser frequency combs and Fabry-Perot etalons to achieve precision sufficient to detect terrestrial mass planets. These high prec…
We demonstrate a new approach to calibrating the spectral-spatial response of a wide-field spectrograph using a fibre etalon comb. Conventional wide-field instruments employed on front-line telescopes are mapped with a grid of diffraction-limited holes cut into a focal plane mask. The aberrated grid pattern in the image plane typically reveals n-symmetric (e.g. pincushion) distortion patterns over the field arising from the optical train. This approach is impractical in the presence of a dispersing element because the diffraction-limited spots in the focal plane are imaged as an array of overl…
Using a turn-key Ti:sapphire femtosecond laser frequency comb, an off-the-shelf supercontinuum device, and Fabry-Perot mode filters, we report the generation of a 16 GHz frequency comb spanning a 90 nm band about a center wavelength of 566 nm. The light from this astro-comb is used to calibrate the HARPS-N astrophysical spectrograph for precision radial velocity measurements. The comb-calibrated spectrograph achieves a stability of $\sim$ 1 cm/s within half an hour of averaging time. We also use the astro-comb as a reference for measurements of solar spectra obtained with a compact telescope, …
In the last decade, white-light illuminated Fabry-Pérot interferometers wave been established as a widely used, relatively simple, reliable, and cost-effective way to precisely calibrate high-resolution echelle spectrographs. However, Terrien et al. (2021) recently reported a chromatic drift of the Fabry-Pérot interferometer installed at the Habitable-zone Planet Finder spectrograph. In particular, they found that the variation of the etalon effective gap size is not achromatic as usually assumed but in fact depends on wavelength. Here, we present a similar study of the Espresso Fabry-Pérot in…
iLocater is a near-infrared, extremely precise radial velocity (EPRV) spectrograph under construction for the dual 8.4 m diameter Large Binocular Telescope (LBT). The instrument will undertake precision radial velocity studies of Earth-like planets orbiting low-mass stars. Operating in the diffraction-limited regime, iLocater uses adaptive optics to efficiently inject starlight directly into single-mode fibers that illuminate a high spectral resolution (R=190,500 median), cryogenic, diffraction-limited spectrograph. To maximize performance, the spectrograph uses a new design strategy for EPRV …
Spectral shaping is critical to many fields of science. In astronomy for example, the detection of exoplanets via the Doppler effect hinges on the ability to calibrate a high resolution spectrograph. Laser frequency combs can be used for this, but the wildly varying intensity across the spectrum can make it impossible to optimally utilize the entire comb, leading to a reduced overall precision of calibration. To circumvent this, astronomical applications of laser frequency combs rely on a bulk optic setup which can flatten the output spectrum before sending it to the spectrograph. Such flatten…
Excalibur is a non-parametric, hierarchical framework for precision wavelength-calibration of spectrographs. It is designed with the needs of extreme-precision radial velocity (EPRV) in mind, which require that instruments be calibrated or stabilized to better than $10^{-4}$ pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an …