Image registration algorithms can be generally categorized into two groups: non-rigid and rigid. Recently, many deep learning-based algorithms employ a neural net to characterize non-rigid image registration function. However, do they always perform better? In this study, we compare the state-of-art deep learning-based non-rigid registration approach with rigid registration approach. The data is generated from Kaggle Dog vs Cat Competition \url{https://www.kaggle.com/c/dogs-vs-cats/} and we test the algorithms' performance on rigid transformation including translation, rotation, scaling, shearing and pixelwise non-rigid transformation. The Voxelmorph is trained on rigidset and nonrigidset separately for comparison and we also add a gaussian blur layer to its original architecture to improve registration performance. The best quantitative results in both root-mean-square error (RMSE) and mean absolute error (MAE) metrics for rigid registration are produced by SimpleElastix and non-rigid registration by Voxelmorph. We select representative samples for visual assessment.
Images taken at different times or positions undergo transformations such as rotation, scaling, skewing, and more. The process of aligning different images which have undergone transformations can be done via registration. Registration is desirable when analyzing time-series data for tracking, averaging, or differential diagnoses of diseases. Efficient registration methods exist for rigid (including linear or affine) transformations; however, for non-rigid (also known as non-affine) transformations, current methods are computationally expensive and time-consuming. In this report, I will explor…
UDCR: Unsupervised Aortic DSA/CTA Rigid Registration Using Deep Reinforcement Learning and Overlap Degree Calculation
School of Artificial Intelligence, Beijing University of Posts and Telecommunications(北京邮电大学人工智能学院);Shanghai Changhai Hospital, Naval Medical University(海军军医大学上海长海医院);Dalian University of Technology(大连理工大学);School of Computer Science and Information Security, Guilin University of Electronic Technology(桂林电子科技大学计算机科学与信息安全学院);The Fourth Hospital of Hebei Medical University and Hebei Tumor Hospital(河北医科大学第四医院暨河北省肿瘤医院);Erasmus MC, University Medical Center Rotterdam(鹿特丹伊拉斯姆斯大学医学中心)
Muroran Institute of Technology(室兰工业大学);Niigata University of Health and Welfare(新潟医疗福祉大学);Konica Minolta, Inc.(柯尼卡美能达公司)
Multi-stain whole-slide-image (WSI) registration is an active field of research. It is unclear, however, how the current WSI registration methods would perform on a real-world data set. AutomatiC Registration Of Breast cAncer Tissue (ACROBAT) challenge is held to verify the performance of the current WSI registration methods by using a new dataset that originates from routine diagnostics to assess real-world applicability. In this report, we present our solution for the ACROBAT challenge. We employ a two-step approach including rigid and non-rigid transforms. The experimental results show that…
Perelman School of Medicine, University of Pennsylvania(宾夕法尼亚大学佩雷尔曼医学院)
A novel non-rigid image registration algorithm is built upon fully convolutional networks (FCNs) to optimize and learn spatial transformations between pairs of images to be registered in a self-supervised learning framework. Different from most existing deep learning based image registration methods that learn spatial transformations from training data with known corresponding spatial transformations, our method directly estimates spatial transformations between pairs of images by maximizing an image-wise similarity metric between fixed and deformed moving images, similar to conventional image…
Image registration for stack-based HDR photography is challenging. If not properly accounted for, camera motion and scene changes result in artifacts in the composite image. Unfortunately, existing methods to address this problem are either accurate, but too slow for mobile devices, or fast, but prone to failing. We propose a method that fills this void: our approach is extremely fast---under 700ms on a commercial tablet for a pair of 5MP images---and prevents the artifacts that arise from insufficient registration quality.
Chalmers University of Technology(查尔姆斯理工大学);MedTech West(西部医疗技术中心)
We study the relation between the target functions of low-resolution and high-resolution intensity-based registration for the class of rigid transformations. Our results show that low resolution target values can tightly bound the high-resolution target function in natural images. This can help with analyzing and better understanding the process of multiresolution image registration. It also gives a guideline for designing multiresolution algorithms in which the search space in higher resolution registration is restricted given the fitness values for lower resolution image pairs. To demonstrat…
Imperial College London(帝国理工学院);Technische Universität München(慕尼黑工业大学);Sharif University of Technology(谢里夫理工大学);Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡大学)
We develop a new Bayesian model for non-rigid registration of three-dimensional medical images, with a focus on uncertainty quantification. Probabilistic registration of large images with calibrated uncertainty estimates is difficult for both computational and modelling reasons. To address the computational issues, we explore connections between the Markov chain Monte Carlo by backpropagation and the variational inference by backpropagation frameworks, in order to efficiently draw samples from the posterior distribution of transformation parameters. To address the modelling issues, we formulat…
We present Free Point Transformer (FPT) - a deep neural network architecture for non-rigid point-set registration. Consisting of two modules, a global feature extraction module and a point transformation module, FPT does not assume explicit constraints based on point vicinity, thereby overcoming a common requirement of previous learning-based point-set registration methods. FPT is designed to accept unordered and unstructured point-sets with a variable number of points and uses a "model-free" approach without heuristic constraints. Training FPT is flexible and involves minimizing an intuitive …
Oregon Health and Science University(俄勒冈健康与科学大学);School of Medicine(医学院);Department of Science and Engineering(科学与工程系)
We introduce an adaptive regularization approach. In contrast to conventional Tikhonov regularization, which specifies a fixed regularization operator, we estimate it simultaneously with parameters. From a Bayesian perspective we estimate the prior distribution on parameters assuming that it is close to some given model distribution. We constrain the prior distribution to be a Gauss-Markov random field (GMRF), which allows us to solve for the prior distribution analytically and provides a fast optimization algorithm. We apply our approach to non-rigid image registration to estimate the spatial…
University College London(伦敦大学学院);University of Leeds(利兹大学)
Biomechanical modelling of soft tissue provides a non-data-driven method for constraining medical image registration, such that the estimated spatial transformation is considered biophysically plausible. This has not only been adopted in real-world clinical applications, such as the MR-to-ultrasound registration for prostate intervention of interest in this work, but also provides an explainable means of understanding the organ motion and spatial correspondence establishment. This work instantiates the recently-proposed physics-informed neural networks (PINNs) to a 3D linear elastic model for …
We propose a novel non-rigid image registration algorithm that is built upon fully convolutional networks (FCNs) to optimize and learn spatial transformations between pairs of images to be registered. Different from most existing deep learning based image registration methods that learn spatial transformations from training data with known corresponding spatial transformations, our method directly estimates spatial transformations between pairs of images by maximizing an image-wise similarity metric between fixed and deformed moving images, similar to conventional image registration algorithms…
Yunnan Normal University(云南师范大学);University of Nottingham Ningbo China(宁波诺丁汉大学);Aba Teachers University(阿坝师范学院)
As an essential processing step before the fusing of infrared and visible images, the performance of image registration determines whether the two images can be fused at correct spatial position. In the actual scenario, the varied imaging devices may lead to a change in perspective or time gap between shots, making significant non-rigid spatial relationship in infrared and visible images. Even if a large number of feature points are matched, the registration accuracy may still be inadequate, affecting the result of image fusion and other vision tasks. To alleviate this problem, we propose a Se…
Centre de Recherche en Automatique de Nancy(南锡自动化研究中心);Nancy-University(南锡大学);CNRS(法国国家科学研究中心)
Bladder cancer is widely spread in the world. Many adequate diagnosis techniques exist. Video-endoscopy remains the standard clinical procedure for visual exploration of the bladder internal surface. However, video-endoscopy presents the limit that the imaged area for each image is about nearly 1cm2. And, lesions are, typically, spread over several images. The aim of this contribution is to assess the performance of two mosaicing algorithms leading to the construction of panoramic maps (one unique image) of bladder walls. The quantitative comparison study is performed on a set of real endoscop…
Rigid slice-to-volume registration is a challenging task, which finds application in medical imaging problems like image fusion for image guided surgeries and motion correction for volume reconstruction. It is usually formulated as an optimization problem and solved using standard continuous methods. In this paper, we discuss how this task be formulated as a discrete labeling problem on a graph. Inspired by previous works on discrete estimation of linear transformations using Markov Random Fields (MRFs), we model it using a pairwise MRF, where the nodes are associated to the rigid parameters, …
University College London(伦敦大学学院);Verdure Imaging, Inc.(Verdure成像公司);Queen’s University(女王大学)
Free Point Transformer (FPT) has been proposed as a data-driven, non-rigid point set registration approach using deep neural networks. As FPT does not assume constraints based on point vicinity or correspondence, it may be trained simply and in a flexible manner by minimizing an unsupervised loss based on the Chamfer Distance. This makes FPT amenable to real-world medical imaging applications where ground-truth deformations may be infeasible to obtain, or in scenarios where only a varying degree of completeness in the point sets to be aligned is available. To test the limit of the corresponden…
Brigham and Women’s Hospital(布莱根妇女医院);Harvard Medical School(哈佛医学院);Graduate School of Frontier Sciences, The University of Tokyo(东京大学前沿科学研究生院);Department of Automation, Tsinghua University(清华大学自动化系);Center for Advanced Intelligence Project, RIKEN(理化学研究所先进智能项目中心)
In image-guided neurosurgery, current commercial systems usually provide only rigid registration, partly because it is harder to predict, validate and understand non-rigid registration error. For instance, when surgeons see a discrepancy in aligned image features, they may not be able to distinguish between registration error and actual tissue deformation caused by tumor resection. In this case, the spatial distribution of registration error could help them make more informed decisions, e.g., ignoring the registration where the estimated error is high. However, error estimates are difficult to…
Impact of Initialization on Intra-subject Pediatric Brain MR Image Registration: A Comparative Analysis between SyN ANTs and Deep Learning-Based Approaches
Polytechnique Montréal(蒙特利尔理工学院);Ste-Justine Hospital University Centre(圣贾斯汀医院大学中心);Université de Strasbourg(斯特拉斯堡大学);CNRS(法国国家科学研究中心)
Biomechanical Constraints Assimilation in Deep-Learning Image Registration: Application to sliding and locally rigid deformations
Centre de Recherches en Cancérologie de Toulouse(图卢兹癌症研究中心);INSERM(法国国家健康与医学研究院);Institut de Mathématiques de Toulouse(图卢兹数学研究所);CNRS(法国国家科学研究中心);Université de Toulouse(图卢兹大学);Institut Universitaire du Cancer – Oncopole Claudius Régaud(克劳迪乌斯·雷戈德肿瘤大学医院研究所)
University of Edinburgh(爱丁堡大学);Imperial College London(帝国理工学院);University of Essex(埃塞克斯大学)
Magnetic Resonance Imaging (MRI) typically recruits multiple sequences (defined here as "modalities"). As each modality is designed to offer different anatomical and functional clinical information, there are evident disparities in the imaging content across modalities. Inter- and intra-modality affine and non-rigid image registration is an essential medical image analysis process in clinical imaging, as for example before imaging biomarkers need to be derived and clinically evaluated across different MRI modalities, time phases and slices. Although commonly needed in real clinical scenarios, …
We describe a point-set registration algorithm based on a novel free point transformer (FPT) network, designed for points extracted from multimodal biomedical images for registration tasks, such as those frequently encountered in ultrasound-guided interventional procedures. FPT is constructed with a global feature extractor which accepts unordered source and target point-sets of variable size. The extracted features are conditioned by a shared multilayer perceptron point transformer module to predict a displacement vector for each source point, transforming it into the target space. The point …
The Wellcome Centre for Human Neuroimaging, UCL(伦敦大学学院惠康人类神经影像中心)
In medical imaging it is common practice to acquire a wide range of modalities (MRI, CT, PET, etc.), to highlight different structures or pathologies. As patient movement between scans or scanning session is unavoidable, registration is often an essential step before any subsequent image analysis. In this paper, we introduce a cost function based on joint total variation for such multimodal image registration. This cost function has the advantage of enabling principled, groupwise alignment of multiple images, whilst being insensitive to strong intensity non-uniformities. We evaluate our algori…
Friedrich-Alexander Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡弗里德里希-亚历山大大学);Siemens Healthineers AG(西门子医疗股份公司);Graduate School in Advanced Optical Technologies (SAOT)(先进光学技术研究生院(SAOT))
Registration of pre-operative 3-D volumes to intra-operative 2-D X-ray images is important in minimally invasive medical procedures. Rigid registration can be performed by estimating a global rigid motion that optimizes the alignment of local correspondences. However, inaccurate correspondences challenge the registration performance. To minimize their influence, we estimate optimal weights for correspondences using PointNet. We train the network directly with the criterion to minimize the registration error. We propose an objective function which includes point-to-plane correspondence-based mo…
University of Coimbra(科英布拉大学);CHUC(科英布拉大学医院中心);The University of Texas at Austin(得克萨斯大学奥斯汀分校);KTH Royal Institute of Technology(瑞典皇家理工学院)
Wireless Capsule Endoscope (WCE) is an innovative imaging device that permits physicians to examine all the areas of the Gastrointestinal (GI) tract. It is especially important for the small intestine, where traditional invasive endoscopies cannot reach. Although WCE represents an extremely important advance in medical imaging, a major drawback that remains unsolved is the WCE precise location in the human body during its operating time. This is mainly due to the complex physiological environment and the inherent capsule effects during its movement. When an abnormality is detected, in the WCE …
Northwestern Polytechnical University(西北工业大学);University of North Carolina at Chapel Hill(北卡罗来纳大学教堂山分校);Shanghai United Imaging Intelligence Co., Ltd(上海联影智能有限公司);Shanghai Jiao Tong University(上海交通大学)
Non-rigid inter-modality registration can facilitate accurate information fusion from different modalities, but it is challenging due to the very different image appearances across modalities. In this paper, we propose to train a non-rigid inter-modality image registration network, which can directly predict the transformation field from the input multimodal images, such as CT and MR images. In particular, the training of our inter-modality registration network is supervised by intra-modality similarity metric based on the available paired data, which is derived from a pre-aligned CT and MR da…
Attention-aware non-rigid image registration for accelerated MR imaging
University Hospital of Tuebingen(蒂宾根大学医院);Klinikum Rechts der Isar(右岸医院(慕尼黑工业大学附属));Technical University of Munich(慕尼黑工业大学);School of Computation, Information and Technology, Technical University of Munich(慕尼黑工业大学计算、信息与技术学院);Imperial College London(伦敦帝国学院)
Robarts Research Institute(罗巴茨研究所);Western University(韦仕敦大学)
Optimization techniques have been widely used in deformable registration, allowing for the incorporation of similarity metrics with regularization mechanisms. These regularization mechanisms are designed to mitigate the effects of trivial solutions to ill-posed registration problems and to otherwise ensure the resulting deformation fields are well-behaved. This paper introduces a novel deformable registration algorithm, RANCOR, which uses iterative convexification to address deformable registration problems under total-variation regularization. Initial comparative results against four state-of…
Disentangle-then-Align: Non-Iterative Hybrid Multimodal Image Registration via Cross-Scale Feature Disentanglement
Faculty of Engineering and IT, University of Technology Sydney(新南威尔士大学工程与信息技术学院);School of Artificial Intelligence, Anhui University(安徽大学人工智能学院);School of Computer Science and Technology, Anhui University(安徽大学计算机科学与技术学院)
Deformable MRI Sequence Registration for AI-based Prostate Cancer Diagnosis
Radboudumc(拉德堡德大学医学中心);Fraunhofer MEVIS(弗劳恩霍夫梅维斯研究所);Universität zu Lübeck(吕贝克大学);University Medical Center Groningen(格罗宁根大学医学中心);Netherlands Cancer Institute(荷兰癌症研究所);Norwegian University of Science and Technology(挪威科技大学)
The non-rigid registration between CT data and ultrasonic images of liver can facilitate the diagnosis and treatment, which has been widely studied in recent years. To improve the registration accuracy of the Demons model on the non-rigid registration between 3D CT liver data and 2D ultrasonic images, a novel boundary extraction and enhancement method based on radial directional local intuitionistic fuzzy entropy in the polar coordinates has been put forward, and a new registration workflow has been provided. Experiments show that our method can acquire high-accuracy registration results. Expe…
Learning accurate rigid registration for longitudinal brain MRI from synthetic data
1 Division of Biomedical Imaging, KTH Royal Institute of Technology, Huddinge, Sweden 2 Athinoula A.\ Martinos Center for Biomedical Imaging, Charlestown, USA 3 Department of Radiology, Massachusetts General Hospital, Boston, USA 4 Department of Radiology, Harvard Medical School, Boston, USA 5 Computer Science \& Artificial Intelligence Laboratory, MIT, Cambridge, USA
We can use a method called registration to integrate some point clouds that represent the shape of the real world. In this paper, we propose highly accurate and stable registration method. Our method detects keypoints from point clouds and generates triplets using multiple descriptors. Furthermore, our method evaluates the consistency of rigid transformation parameters of each triplet with histograms and obtains the rigid transformation between the point clouds. In the experiment of this paper, our method had minimul errors and no major failures. As a result, we obtained sufficiently accurate …
Robust Rigid and Non-Rigid Medical Image Registration Using Learnable Edge Kernels
Department of Mathematics, University of Innsbruck(因斯布鲁克大学数学系);Department of Radiology, Medical University of Innsbruck(因斯布鲁克医学大学放射学系);Neuroimaging Research Core Facility, Medical University of Innsbruck(因斯布鲁克医学大学神经影像研究核心设施)
This paper addresses the issue of matching rigid 3D object points with 2D image points through point registration based on maximum likelihood principle in computer simulated images. Perspective projection is necessary when transforming 3D coordinate into 2D. The problem then recasts into a missing data framework where unknown correspondences are handled via mixture models. Adopting the Expectation Conditional Maximization for Point Registration (ECMPR), two different rotation and translation optimization algorithms are compared in this paper. We analyze in detail the associated consequences in…
Uppsala University(乌普萨拉大学);University of Copenhagen(哥本哈根大学)
Despite current advancement in the field of biomedical image processing, propelled by the deep learning revolution, multimodal image registration, due to its several challenges, is still often performed manually by specialists. The recent success of image-to-image (I2I) translation in computer vision applications and its growing use in biomedical areas provide a tempting possibility of transforming the multimodal registration problem into a, potentially easier, monomodal one. We conduct an empirical study of the applicability of modern I2I translation methods for the task of rigid registration…
Image registration plays an important role in comparing images. It is particularly important in analyzing medical images like CT, MRI, PET, etc. to quantify different biological samples, to monitor disease progression and to fuse different modalities to support better diagnosis. The recent emergence of tissue clearing protocols enable us to take images at cellular level resolution. Image registration tools developed for other modalities are currently unable to manage images of such extreme high resolution. The recent popularity of deep learning based methods in the computer vision community ju…
An Optimization-based Baseline for Rigid 2D/3D Registration Applied to Spine Surgical Navigation Using CMA-ES
School of Computer Science and Engineering, Southeast University(东南大学计算机科学与工程学院);Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, Southeast University(东南大学江苏省医学信息处理协同创新国际联合实验室);Key Laboratory of New Generation Artificial Intelligence Technology and Its Interdisciplinary Applications (Southeast University), Ministry of Education(教育部新一代人工智能技术及其交叉应用重点实验室(东南大学))
National University of Defense Technology(国防科技大学);Technical University of Munich(慕尼黑工业大学)
We study the problem of outlier correspondence pruning for non-rigid point cloud registration. In rigid registration, spatial consistency has been a commonly used criterion to discriminate outliers from inliers. It measures the compatibility of two correspondences by the discrepancy between the respective distances in two point clouds. However, spatial consistency no longer holds in non-rigid cases and outlier rejection for non-rigid registration has not been well studied. In this work, we propose Graph-based Spatial Consistency Network (GraphSCNet) to filter outliers for non-rigid registratio…
We present a new fully-automatic non-rigid 3D shape registration (morphing) framework comprising (1) a new 3D landmarking and pose normalisation method; (2) an adaptive shape template method to accelerate the convergence of registration algorithms and achieve a better final shape correspondence and (3) a new iterative registration method that combines Iterative Closest Points with Coherent Point Drift (CPD) to achieve a more stable and accurate correspondence establishment than standard CPD. We call this new morphing approach Iterative Coherent Point Drift (ICPD). Our proposed framework is eva…
INRIA Grenoble Rhône-Alpes(法国国立信息学与自动化研究院格勒诺布尔罗讷-阿尔卑斯分院);University of Hong Kong(香港大学)
This paper addresses the issue of matching rigid and articulated shapes through probabilistic point registration. The problem is recast into a missing data framework where unknown correspondences are handled via mixture models. Adopting a maximum likelihood principle, we introduce an innovative EM-like algorithm, namely the Expectation Conditional Maximization for Point Registration (ECMPR) algorithm. The algorithm allows the use of general covariance matrices for the mixture model components and improves over the isotropic covariance case. We analyse in detail the associated consequences in t…
Beijing Anzhen Hospital, Capital Medical University(首都医科大学附属北京安贞医院);Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application(临床应用生物力学基础研究北京市重点实验室);Beijing Institute of Heart, Lung & Blood Vessel Diseases(北京市心肺血管疾病研究所)
Since the mapping relationship between definitized intra-interventional X-ray and undefined pre-interventional Computed Tomography(CT) is uncertain, auxiliary positioning devices or body markers, such as medical implants, are commonly used to determine this relationship. However, such approaches can not be widely used in clinical due to the complex realities. To determine the mapping relationship, and achieve a initializtion post estimation of human body without auxiliary equipment or markers, proposed method applies image segmentation and deep feature matching to directly match the X-ray and …
Non-rigid point cloud registration is a key component in many computer vision and computer graphics applications. The high complexity of the unknown non-rigid motion make this task a challenging problem. In this paper, we break down this problem via hierarchical motion decomposition. Our method called Neural Deformation Pyramid (NDP) represents non-rigid motion using a pyramid architecture. Each pyramid level, denoted by a Multi-Layer Perception (MLP), takes as input a sinusoidally encoded 3D point and outputs its motion increments from the previous level. The sinusoidal function starts with a…
Cardiff University(卡迪夫大学);University of Science and Technology of China(中国科学技术大学);Università della Svizzera italiana(瑞士意大利语区大学)
Non-rigid registration computes an alignment between a source surface with a target surface in a non-rigid manner. In the past decade, with the advances in 3D sensing technologies that can measure time-varying surfaces, non-rigid registration has been applied for the acquisition of deformable shapes and has a wide range of applications. This survey presents a comprehensive review of non-rigid registration methods for 3D shapes, focusing on techniques related to dynamic shape acquisition and reconstruction. In particular, we review different approaches for representing the deformation field, an…
This work addresses the problem of non-rigid registration of 3D scans, which is at the core of shape modeling techniques. Firstly, we propose a new kernel based on geodesic distances for the Gaussian Process Morphable Models (GPMMs) framework. The use of geodesic distances into the kernel makes it more adapted to the topological and geometric characteristics of the surface and leads to more realistic deformations around holes and curved areas. Since the kernel possesses hyperparameters we have optimized them for the task of face registration on the FaceWarehouse dataset. We show that the Geode…
MSR:Hybrid Field Modeling for CT-MRI Rigid-Deformable Registration of the Cervical Spine with an Annotated Dataset
School of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, China.(南方医科大学生物医学工程学院);Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, 510515, China.(广东省医学图像处理重点实验室);Guangdong Province Engineering Laboratory for Medical Imaging(广东省医学影像与诊断技术工程实验室);Information Center, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.(南方医科大学南华医院信息中心);Division of Spine Surgery, Department of Orthopaedics, Nanfang hospital, Southern Medical University, Guangzhou, Guangdong, 510515, China.(南方医科大学南华医院骨科脊柱外科)
In this paper, we unify popular non-rigid registration methods for point sets and surfaces under our general framework, GiNGR. GiNGR builds upon Gaussian Process Morphable Models (GPMM) and hence separates modeling the deformation prior from model adaptation for registration. In addition, it provides explainable hyperparameters, multi-resolution registration, trivial inclusion of expert annotation, and the ability to use and combine analytical and statistical deformation priors. But more importantly, the reformulation allows for a direct comparison of registration methods. Instead of using a g…
Non-rigid registration is challenging because it is ill-posed with high degrees of freedom and is thus sensitive to noise and outliers. We propose a robust non-rigid registration method using reweighted sparsities on position and transformation to estimate the deformations between 3-D shapes. We formulate the energy function with position and transformation sparsity on both the data term and the smoothness term, and define the smoothness constraint using local rigidity. The double sparsity based non-rigid registration model is enhanced with a reweighting scheme, and solved by transferring the …
Britton Chance Center for Biomedical Photonics(布里顿·钱斯生物医学光子学研究中心);Wuhan National Laboratory for Optoelectronics(武汉光电国家研究中心);MoE Key Laboratory for Biomedical Photonics(教育部生物医学光子学重点实验室);Collaborative Innovation Center for Biomedical Engineering(生物医学工程协同创新中心);School of Engineering Sciences, Huazhong University of Science and Technology(华中科技大学工程科学学院)
Registration of brain MRI images requires to solve a deformation field, which is extremely difficult in aligning intricate brain tissues, e.g., subcortical nuclei, etc. Existing efforts resort to decomposing the target deformation field into intermediate sub-fields with either tiny motions, i.e., progressive registration stage by stage, or lower resolutions, i.e., coarse-to-fine estimation of the full-size deformation field. In this paper, we argue that those efforts are not mutually exclusive, and propose a unified framework for robust brain MRI registration in both progressive and coarse-to-…
Objects that undergo non-rigid deformation are common in the real world. A typical and challenging example is the human faces. While various techniques have been developed for deformable shape registration and classification, benchmarks with detailed labels and landmarks suitable for evaluating such techniques are still limited. In this paper, we present a novel facial dynamic dataset HDFD which addresses the gap of existing datasets, including 4D funny faces with substantial non-isometric deformation, and 4D visual-audio faces of spoken phrases in a minority language (Welsh). Both datasets ar…
Fudan University(复旦大学);Technical University of Munich(慕尼黑工业大学)
The rigid registration of two 3D point sets is a fundamental problem in computer vision. The current trend is to solve this problem globally using the BnB optimization framework. However, the existing global methods are slow for two main reasons: the computational complexity of BnB is exponential to the problem dimensionality (which is six for 3D rigid registration), and the bound evaluation used in BnB is inefficient. In this paper, we propose two techniques to address these problems. First, we introduce the idea of translation invariant vectors, which allows us to decompose the search of a 6…
University of Stuttgart(斯图加特大学);ShanghaiTech University(上海科技大学);RMIT University(皇家墨尔本理工大学)
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of reliable non-rigid motion fields from the undersampled motion-resolved data. Motion estimation is usually formulated in image space via diffusion, parametric-spline, or optical flow methods. However, im…
The Discriminative Optimization (DO) algorithm has been proved much successful in 3D point cloud registration. In the original DO, the feature (descriptor) of two point cloud was defined as a histogram, and the element of histogram indicates the weights of scene points in "front" or "back" side of a model point. In this paper, we extended the histogram which indicate the sides from "front-back" to "front-back", "up-down", and "clockwise-anticlockwise". In addition, we reweighted the extended histogram according to the model points' distribution. We evaluated the proposed Improved DO on the Sta…
Point set registration is a key component in many computer vision tasks. The goal of point set registration is to assign correspondences between two sets of points and to recover the transformation that maps one point set to the other. Multiple factors, including an unknown non-rigid spatial transformation, large dimensionality of point set, noise and outliers, make the point set registration a challenging problem. We introduce a probabilistic method, called the Coherent Point Drift (CPD) algorithm, for both rigid and non-rigid point set registration. We consider the alignment of two point set…
Given two point sets, the problem of registration is to recover a transformation that matches one set to the other. This task is challenging due to the presence of the large number of outliers, the unknown non-rigid deformations and the large sizes of point sets. To obtain strong robustness against outliers, we formulate the registration problem as a partial distribution matching (PDM) problem, where the goal is to partially match the distributions represented by point sets in a metric space. To handle large point sets, we propose a scalable PDM algorithm by utilizing the efficient partial Was…