arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2001.03342cond-mat.mes-hallcond-mat.supr-con

SQUID-on-tip with single-electron spin sensitivity for high-field and ultra-low temperature nanomagnetic imaging

Y. Anahory, H. R. Naren, E. O. Lachman, S. Buhbut Sinai, A. Uri, L. Embon, E. Yaakobi, Y. Myasoedov, M. E. Huber, R. Klajn, E. Zeldov

英文摘要:

Scanning nanoscale superconducting quantum interference devices (nanoSQUIDs) are of growing interest for highly sensitive quantitative imaging of magnetic, spintronic, and transport properties of low-dimensional systems. Utilizing specifically designed grooved quartz capillaries pulled into a sharp pipette, we have fabricated the smallest SQUID-on-tip (SOT) devices with effective diameters down to 39 nm. Integration of a resistive shunt in close proximity to the pipette apex combined with self-aligned deposition of In and Sn, have resulted in SOT with a flux noise of 42 n$Φ_0$Hz$^{-1/2}$, yielding a record low spin noise of 0.29 $μ_B$Hz$^{-1/2}$. In addition, the new SOTs function at sub-Kelvin temperatures and in high magnetic fields of over 2.5 T. Integrating the SOTs into a scanning probe microscope allowed us to image the stray field of a single Fe$_3$O$_4$ nanocube at 300 mK. Our results show that the easy magnetization axis direction undergoes a transition from the (111) direction at room temperature to an in-plane orientation, which could be attributed to the Verwey phase transition in Fe$_3$O$_4$.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑