高速离子电导显微镜的发展
Development of High-Speed Ion Conductance Microscopy
摘要:
扫描离子电导显微镜(SICM)可以在离子溶液中成像样品的表面形貌,而无需机械探针-样品接触。这种独特的能力有利于对脆弱的生物样品进行成像,但其最高可能的成像率远低于生物研究中所需的水平。在这里,我们介绍了高速SICM的发展。通过具有主动振动控制的快速Z扫描仪和具有增强的离子电导的移液管探针来实现快速成像能力。通过前者,探头Z定位的延迟被最小化到低于10 μ s,而其最大行程被保证在6 μ m。增强的离子电导降低了离子电流检测中的本底噪声,将检测带宽增加到100 kHz。因此,实现了比传统系统高100倍的时间分辨率,以及约20 nm的空间分辨率。
英文摘要:
Scanning ion conductance microscopy (SICM) can image the surface topography of specimens in ionic solutions without mechanical probe--sample contact. This unique capability is advantageous for imaging fragile biological samples but its highest possible imaging rate is far lower than the level desired in biological studies. Here, we present the development of high-speed SICM. The fast imaging capability is attained by a fast Z-scanner with active vibration control and pipette probes with enhanced ion conductance. By the former, the delay of probe Z-positioning is minimized to sub-10 us, while its maximum stroke is secured at 6 um. The enhanced ion conductance lowers a noise floor in ion current detection, increasing the detection bandwidth up to 100 kHz. Thus, temporal resolution 100-fold higher than that of conventional systems is achieved, together with spatial resolution around 20 nm.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。