arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1910.05152physics.plasm-ph
收藏

脉冲DC偏压用于低压氢等离子体中绝缘材料表面负离子产生的研究

Pulsed DC bias for the study of negative-ion production on surfaces of insulating materials in low pressure hydrogen plasmas

K. Achkasov, R. Moussaoui, D. Kogut, E. Garabedian, J. Layet, A. Simonin, A. Gicquel, J. Achard, A. Boussadi, G. Cartry

摘要:

在这项工作中,负离子的产生上的负直流偏置在氢等离子体中的样品的表面上进行了研究。在正离子轰击下产生的负离子被加速朝向等离子体,通过放置在样品前面的质谱仪根据它们的能量和质量自提取和检测。脉冲偏压的使用允许在短时间内在绝缘材料上施加准直流偏压,并提供了将测量方法扩展到非导电样品的可能性。首先用高取向热解石墨(HOPG)导电材料进行脉冲偏压测试,以证明该方法的可行性。通过改变脉冲偏置频率,可以获得具有不同氢表面覆盖率的HOPG材料,因此不同的表面状态导致负离子产生与连续偏置情况相比增加高达30-50%。为了建立一个协议的绝缘材料,电荷积累的表面上的偏置脉冲和偏压的持续时间和频率的影响进行了探讨,使用微晶金刚石(MCD)薄层。通过在1 kHz频率下使用足够短(10 $μ$ s)的脉冲,可以在130 V的准恒定表面偏压下测量MCD样品上的负离子,在测量期间只有1 V的变化。在脉冲模式下研究了MCD表面负离子的产生,表面温度从室温到800{ \textdegree }C。结果表明,脉冲偏压和提高温度允许限制MCD上的缺陷产生,这有利于负离子的产生。因此,在400{ \textdegree }C下,在脉冲模式下MCD上的产率比在室温下连续模式下HOPG上的产率高一个数量级。

英文摘要:

In this work negative-ion production on the surface of a sample negatively DC biased in a hydrogen plasma is studied. The negative ions created under the positive ion bombardment are accelerated towards the plasma, self-extracted and detected according to their energy and mass, by a mass spectrometer placed in front of the sample. The use of a pulsed bias allows applying a quasi-DC bias on insulating material during a short period of time and offers the possibility to extend the measurement method to nonconductive samples. The pulsed-bias tests were performed first with Highly Oriented Pyrolitic Graphite (HOPG), a conductive material, to demonstrate the feasibility of the method. By changing the pulsed-bias frequency it was possible to obtain HOPG material with different hydrogen surface coverages and hence different surface states leading to an increase of negative-ion production by up to 30-50% as compared to the continuous bias case. To establish a protocol for insulating materials, charge accumulation on the surface during the bias pulse and influence of the bias duration and frequency were explored using microcrystalline diamond (MCD) thin layers. By using a pulse short enough (10 $μ$s) at 1 kHz frequency, it has been possible to measure negative-ions on MCD sample at a quasi-constant surface bias of 130 V, with only 1 V variation during the measurement. Negative-ion surface production on MCD has been studied in pulsed mode with surface temperature from room temperature to 800{\textdegree}C. It is shown that pulsing the bias and increasing the temperature allows limiting defect creation on MCD which is favorable for negative-ion production. Consequently, at 400{\textdegree}C the yield on MCD in pulsed mode is one order of magnitude higher than the yield on HOPG in continuous mode at room temperature.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑