数字束流位置测量采样方法研究
Research into the sampling methods of digital beam position measurement
摘要:
束流位置测量系统是加速器中最重要的束流诊断仪器之一。为上海同步辐射装置(SSRF)设计了一个全数字式BPM(DBPM)。由于模数转换器(ADC)是DBPM系统中的关键部件,因此需要对采样方法进行研究以获得最佳性能。我们实现了不同的采样模式,并通过测试进行了比较。同时,四个采样通道之间的长期变化是另一个问题,这将在束流位置测量中引入误差。我们设计了一个交错分布方案来解决这个问题。为了评估这些采样方法,我们在SSRF中对束流进行了调试测试。测试结果表明,采用适当的采样方法,可以获得优于1 μ m的逐圈(TBT)位置分辨率,采用交错分布后,可以将慢捕获(SA)位置分辨率从4.28 μm提高到0.17 μm,均达到要求。
英文摘要:
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter (ADC) is one crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. We implemented different sampling modes and compared them through tests. Meanwhile, long term variation among four sampling channels is another concern, which would introduce errors in beam position measurement. We designed an interleaved distribution scheme to address this issue. To evaluate these sampling methods, we conducted commissioning tests with the beam in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn (TBT) position resolution better than 1 um is achieved, and the slow-acquisition (SA) position resolution is enhanced from 4.28 μm to 0.17 μm successfully with interleaved distribution applied, both beyond requirement.