In PET/CT imaging, CT is used for PET attenuation correction (AC). Mismatch between CT and PET due to patient body motion results in AC artifacts. In addition, artifact caused by metal, beam-hardening and count-starving in CT itself also introduces inaccurate AC for PET. Maximum likelihood reconstruction of activity and attenuation (MLAA) was proposed to solve those issues by simultaneously reconstructing tracer activity ($λ$-MLAA) and attenuation map ($μ$-MLAA) based on the PET raw data only. However, $μ$-MLAA suffers from high noise and $λ$-MLAA suffers from large bias as compared to the reconstruction using the CT-based attenuation map ($μ$-CT). Recently, a convolutional neural network (CNN) was applied to predict the CT attenuation map ($μ$-CNN) from $λ$-MLAA and $μ$-MLAA, in which an image-domain loss (IM-loss) function between the $μ$-CNN and the ground truth $μ$-CT was used. However, IM-loss does not directly measure the AC errors according to the PET attenuation physics, where the line-integral projection of the attenuation map ($μ$) along the path of the two annihilation events, instead of the $μ$ itself, is used for AC. Therefore, a network trained with the IM-loss may yield suboptimal performance in the $μ$ generation. Here, we propose a novel line-integral projection loss (LIP-loss) function that incorporates the PET attenuation physics for $μ$ generation. Eighty training and twenty testing datasets of whole-body 18F-FDG PET and paired ground truth $μ$-CT were used. Quantitative evaluations showed that the model trained with the additional LIP-loss was able to significantly outperform the model trained solely based on the IM-loss function.
POUR-Net: A Population-Prior-Aided Over-Under-Representation Network for Low-Count PET Attenuation Map Generation
Yale University(耶鲁大学);University of California Irvine(加利福尼亚大学尔湾分校);Canon Medical Research USA Inc.(佳能医疗研究美国公司);Siemens Medical Solutions Inc.(西门子医疗解决方案公司)
2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction
Yale School of Medicine(耶鲁医学院);University of California Irvine(加州大学欧文分校);Yale University(耶鲁大学)
Generalizable CT-Free PET Attenuation and Scatter Correction for Pediatric Patients
School of Computing and Artificial Intelligence, Southwestern University of Finance and Economics(西南财经大学计算机学院);Department of Nuclear Medicine, Beijing Friendship Hospital, Capital Medical University(首都医科大学北京友谊医院核医学科);Department of Radiology, Beijing Children’s Hospital, Capital Medical University, National Center for Children’s Health(首都医科大学北京儿童医院放射科)
Attenuation artifact detection and severity classification in intracoronary OCT using mixed image representations
Amsterdam UMC(阿姆斯特丹大学医学中心);University of Amsterdam(阿姆斯特丹大学);Amsterdam Cardiovascular Sciences(阿姆斯特丹心血管科学中心);Radboud University Medical Center(拉德堡德大学医学中心)
A robust multi-domain network for short-scanning amyloid PET reconstruction
National Institute for Mathematical Sciences(数学科学国家研究院);Department of Nuclear Medicine, Dong-A University Hospital(东阿大学医院核医学系);College of Medicine, Dong-A University(东阿大学医学院)
FedFTN: Personalized Federated Learning with Deep Feature Transformation Network for Multi-institutional Low-count PET Denoising
Yale University(耶鲁大学);University of Southern California(南加州大学);University of California Irvine(加州大学欧文分校);University of Science and Technology of China(中国科学技术大学);Ruijin Hospital, Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属瑞金医院);Inselspital, Bern University Hospital(伯尔尼大学医院 Inselspital);University of Bern(伯尔尼大学);Technical University of Munich(慕尼黑工业大学)
Cycle-Constrained Adversarial Denoising Convolutional Network for PET Image Denoising: Multi-Dimensional Validation on Large Datasets with Reader Study and Real Low-Dose Data