arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1908.08947eess.IVcs.CV

Fast Dynamic Perfusion and Angiography Reconstruction using an end-to-end 3D Convolutional Neural Network

Leiden University Medical Center(莱顿大学医学中心);Delft University of Technology(代尔夫特理工大学)

Sahar Yousefi, Lydiane Hirschler, Merlijn van der Plas, Mohamed S. Elmahdy, Hessam Sokooti, Matthias Van Osch, Marius Staring

英文摘要:

Hadamard time-encoded pseudo-continuous arterial spin labeling (te-pCASL) is a signal-to-noise ratio (SNR)-efficient MRI technique for acquiring dynamic pCASL signals that encodes the temporal information into the labeling according to a Hadamard matrix. In the decoding step, the contribution of each sub-bolus can be isolated resulting in dynamic perfusion scans. When acquiring te-ASL both with and without flow-crushing, the ASL-signal in the arteries can be isolated resulting in 4D-angiographic information. However, obtaining multi-timepoint perfusion and angiographic data requires two acquisitions. In this study, we propose a 3D Dense-Unet convolutional neural network with a multi-level loss function for reconstructing multi-timepoint perfusion and angiographic information from an interleaved $50\%$-sampled crushed and $50\%$-sampled non-crushed data, thereby negating the additional scan time. We present a framework to generate dynamic pCASL training and validation data, based on models of the intravascular and extravascular te-pCASL signals. The proposed network achieved SSIM values of $97.3 \pm 1.1$ and $96.2 \pm 11.1$ respectively for 4D perfusion and angiographic data reconstruction for 313 test data-sets.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑