基于深度学习的单次扫描光学相干断层扫描血管造影(OCTA)血管提取

Deep-Learning-based Vasculature Extraction for Single-Scan Optical Coherence Tomography Angiography

School of Science and Engineering, University of Dundee(邓迪大学科学与工程学院)

Jinpeng Liao, Tianyu Zhang, Yilong Zhang, Chunhui Li, Zhihong Huang

AI总结:

针对传统OCTA血管提取需多次重复扫描、采集时间长且易产生运动伪影的问题,提出基于卷积投影的血管提取Transformer(VET),单次扫描即可生成中等质量、高对比度的OCTA图像,大幅缩短采集时间且在难扫描区域表现更优。

摘要:

光学相干断层扫描血管造影(Optical coherence tomography angiography, OCTA)是一种非侵入性成像模态,通过从周围静态生物组织中提取运动的红细胞信号来扩展光学相干断层扫描(OCT)的功能。OCTA 已成为分析皮肤微血管系统的宝贵工具,可实现更准确的诊断和治疗监测。\n现有的大多数 OCTA 提取算法,例如散斑方差(speckle variance, SV)-OCTA 和特征分解(eigen-decomposition, ED)-OCTA,都需要在同一位置进行大量重复(number of repeated, NR)OCT 扫描才能生成高质量的血管造影图像。然而,更高的 NR 需要更长的数据采集时间,会导致更多不可预测的运动伪影。\n在本研究中,我们提出了一种仅使用1次重复 OCT 扫描即可生成 OCTA 图像的血管提取流程。该流程基于我们提出的血管提取Transformer(Vasculature Extraction Transformer, VET),它利用卷积投影更好地学习图像块之间的空间关系。\n与使用4次重复 OCT 扫描的 SV-OCTA(峰值信噪比 PSNR:17.809)和 ED-OCTA(PSNR:18.049)获得的 OCTA 图像相比,VET 提取的 OCTA 图像质量中等(PSNR:17.515)且图像对比度更高,同时将所需的数据采集时间从约8秒缩短至约2秒。基于视觉观察,在颈部和面部的 OCTA 数据扫描困难区域中,所提出的 VET 表现优于 SV 和 ED 算法。本研究表明,VET 能够从快速的单次重复 OCT 扫描中提取血管图像,为患者的准确诊断提供助力。

英文摘要:

Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that extends the functionality of OCT by extracting moving red blood cell signals from surrounding static biological tissues. OCTA has emerged as a valuable tool for analyzing skin microvasculature, enabling more accurate diagnosis and treatment monitoring. Most existing OCTA extraction algorithms, such as speckle variance (SV)- and eigen-decomposition (ED)-OCTA, implement a larger number of repeated (NR) OCT scans at the same position to produce high-quality angiography images. However, a higher NR requires a longer data acquisition time, leading to more unpredictable motion artifacts. In this study, we propose a vasculature extraction pipeline that uses only one-repeated OCT scan to generate OCTA images. The pipeline is based on the proposed Vasculature Extraction Transformer (VET), which leverages convolutional projection to better learn the spatial relationships between image patches. In comparison to OCTA images obtained via the SV-OCTA (PSNR: 17.809) and ED-OCTA (PSNR: 18.049) using four-repeated OCT scans, OCTA images extracted by VET exhibit moderate quality (PSNR: 17.515) and higher image contrast while reducing the required data acquisition time from ~8 s to ~2 s. Based on visual observations, the proposed VET outperforms SV and ED algorithms when using neck and face OCTA data in areas that are challenging to scan. This study represents that the VET has the capacity to extract vascularture images from a fast one-repeated OCT scan, facilitating accurate diagnosis for patients.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑