收藏

基于深度学习的CT血管造影颅内动脉瘤检测与定位

Deep Learning Based Detection and Localization of Intracranial Aneurysms in Computed Tomography Angiography

Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School(麻省总医院与哈佛医学院高级医学计算与分析中心);Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School(麻省总医院与哈佛医学院戈登医学影像中心);Department of Radiology, Massachusetts General Hospital and Harvard Medical School(麻省总医院与哈佛医学院放射科)

Dufan Wu, Daniel Montes, Ziheng Duan, Yangsibo Huang, Javier M. Romero, Ramon Gilberto Gonzalez, Quanzheng Li

摘要:

目的:开发CADIA,一种基于区域建议网络的监督式深度学习模型,结合假阳性减少模块,用于从计算机断层扫描血管造影(CTA)中检测和定位颅内动脉瘤(IA),并评估我们的模型在类似检测网络中的性能。研究方法:在这项回顾性研究中,我们评估了来自两个独立机构的1,216例接受CT检查的囊性IA>=2.5 mm的患者。实施了两步模型:用于初始动脉瘤检测的3D区域建议网络和用于假阳性减少和进一步确定可疑IA的3D DenseNets。还进行了自由应答受试者操作特征(FROC)曲线和在确定的每体积假阳性(FPPV)下的病变/患者水平性能。使用Fisher精确检验与类似的可用模型进行比较。结果:CADIA在0.25和1FPPV时的灵敏度分别为63.9%和77.5%。我们的模型的性能随尺寸和位置而变化,并且在5-10 mm的IA和前交通动脉中实现了最佳性能,在1 FPPV处的灵敏度分别为95.8%和94%。与0.25 FPPV和最佳F-1评分的可用模型相比,我们的模型显示出统计学上更高的患者水平准确性、灵敏度和特异性(P<=0.001)。在1 FPPV阈值时,我们的模型显示出更好的准确性和特异性(P<=0.001)和等效的灵敏度。结论:CADIA在IA的检测任务中优于可比网络。增加一个假阳性减少模块是一个可行的步骤,以改善IA检测模型。

英文摘要:

Purpose: To develop CADIA, a supervised deep learning model based on a region proposal network coupled with a false-positive reduction module for the detection and localization of intracranial aneurysms (IA) from computed tomography angiography (CTA), and to assess our model's performance to a similar detection network. Methods: In this retrospective study, we evaluated 1,216 patients from two separate institutions who underwent CT for the presence of saccular IA>=2.5 mm. A two-step model was implemented: a 3D region proposal network for initial aneurysm detection and 3D DenseNetsfor false-positive reduction and further determination of suspicious IA. Free-response receiver operative characteristics (FROC) curve and lesion-/patient-level performance at established false positive per volume (FPPV) were also performed. Fisher's exact test was used to compare with a similar available model. Results: CADIA's sensitivities at 0.25 and 1 FPPV were 63.9% and 77.5%, respectively. Our model's performance varied with size and location, and the best performance was achieved in IA between 5-10 mm and in those at anterior communicating artery, with sensitivities at 1 FPPV of 95.8% and 94%, respectively. Our model showed statistically higher patient-level accuracy, sensitivity, and specificity when compared to the available model at 0.25 FPPV and the best F-1 score (P<=0.001). At 1 FPPV threshold, our model showed better accuracy and specificity (P<=0.001) and equivalent sensitivity. Conclusions: CADIA outperformed a comparable network in the detection task of IA. The addition of a false-positive reduction module is a feasible step to improve the IA detection models.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑