arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1902.03200cond-mat.mtrl-sci
收藏

劳厄三维中子衍射

Laue three dimensional neutron diffraction

Marc Raventós, Michael Tovar, Marisa Medarde, Tian Shang, Markus Strobl, Stavros Samothrakitis, Ekaterina Pomjakushina, Christian Grünzweig, Søren Schmidt

摘要:

本文介绍了一种测量技术和数据分析工具,使用中子进行三维晶粒分布映射和索引的低聚晶体样品:劳厄三维中子衍射(劳厄3DND)。该方法建立在用于测量衍射斑点相对于单个颗粒的相关性和多重拟合的正向建模的基础上,这不仅可以识别单个颗粒,还可以识别它们在样品中的位置和方向。利用立方(α-Fe)和四方(YBaCuFeO 5)对称性的多晶粒合成数据集测试了Laue 3DND方法的可行性和性能。接下来,给出了在柏林亥姆霍兹中心的ECOCON仪器上测量的两个数据集的实验结果:一个直径为5 mm、高度为5 mm的圆柱形α铁(α-Fe)参考样品,以及一个2 mm 3的层状钙钛矿(YBaCuFeO 5)。利用Laue 3DND,我们能够从合成的α-Fe数据集中检索出100个晶粒中的97个,以及在TSCCON测量的α-Fe和YBaCuFeO 5样品中分别检索出24个和9个晶粒的位置和取向。合成测试的结果还表明,劳厄3DND能够在两种极端情况下为两种对称性索引10个颗粒中的10个颗粒:仅使用6个劳厄投影和使用360个具有极强噪声数据的投影。该方法的空间分辨率和方向分辨率分别为430μm和1度。基于这些结果,我们有信心提出一种工具,扩展了标准劳厄衍射的能力,提供了数量,位置,取向和相对大小的晶粒在寡晶样品。

英文摘要:

This article presents a measurement technique and data analysis tool to perform 3D grain distribution mapping and indexing of oligocrystalline samples using neutrons: Laue three-dimensional neutron diffraction (Laue3DND). The approach builds on forward modelling used for correlation and multiple fitting of the measured diffraction spots relative to individual grains.This enables not only to identify individual grains, but also their position and orientation in the sample. The feasibility and performance of the Laue3DND approach are tested using multi-grain synthetic datasets from cubic (α-Fe) and tetragonal(YBaCuFeO5) symmetries. Next, experimental results from two data sets measured at the FALCON instrument of Helmholtz-Zentrum Berlin are presented: A cylindrical alpha iron (α-Fe) reference sample with 5 mm diameter and 5 mm height, as well as a 2 mm3 layered perovskite (YBaCuFeO5). Using Laue3DND, we were able to retrieve the position and orientation of 97 out of 100 grains from a syntheticα-Fe data set, as well as 24 and 9 grains respectively from theα-Fe and YBaCuFeO5 sample measured at FALCON. Results from the synthetic tests also indicate that Laue3DND is capable of indexing 10 out of 10 grains for both symmetries in two extreme scenarios: using only 6 Laue projections and using 360 projections with extremely noisy data. The precision achieved in terms of spatial and orientation resolution for the current version of the method is 430μm and 1 degree respectively. Based on these results obtained, we are confident to present a tool that expands the capabilities of standard Laue diffraction, providing the number, position, orientation and relative size of grains in oligocrystalline samples.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑