arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1809.02175physics.opticsphysics.ins-det
收藏

光学频率梳光声光谱

Optical frequency comb photoacoustic spectroscopy

Ibrahim Sadiek, Tommi Mikkonen, Markku Vainio, Juha Toivonen, Aleksandra Foltynowicz

AI总结:

本文首次提出光学频率梳光声光谱(OFC-PAS),结合频率梳宽带高分辨率与悬臂增强光声检测,实现小体积样品中多组分痕量气体的高分辨高选择性分析。

摘要:

我们报道了首个使用光学频率梳的光声检测方案——光学频率梳光声光谱(OFC-PAS)。OFC-PAS将光学频率梳的宽光谱覆盖范围和高分辨率与悬臂增强光声检测的小样品体积相结合。在OFC-PAS中,使用傅里叶变换光谱仪(FTS)以由其扫描速度决定的频率调制激发频率梳源的强度。FTS的一个输出被导向光声池,另一个输出同时用光电二极管测量并用于归一化光声信号。悬臂增强光声探测器工作在非共振模式,能够检测宽带频率响应。通过测量CH₄的基频C-H伸缩振动带的振转光谱,在1000 mbar、650 mbar和400 mbar的总压力下,展示了OFC-PAS的宽带和高分辨率能力,且没有仪器线形畸变。在首次演示中,获得了比先前报道的宽带光声光谱高两个数量级的光谱分辨率,该分辨率受压力展宽限制。在单次干涉图测量中(200 s测量时间,1000 MHz分辨率,1000 mbar总压力),对于42 μW/cm⁻¹的激发功率谱密度,实现了对N₂中甲烷0.8 ppm的检测限。获得了8×10⁻¹⁰ W cm⁻¹ Hz⁻¹/²的归一化噪声等效吸收,仅比基于连续波激光的光声光谱所报道的最佳值高三倍。实现了高达四个数量级的宽动态范围,以及在两个数量级范围内非常好的线性度(受比尔-朗伯定律限制)。OFC-PAS扩展了光学传感器在小样品体积中以高分辨率和选择性进行多组分痕量气体分析的能力。

英文摘要:

We report the first photoacoustic detection scheme using an optical frequency comb - the optical frequency comb photoacoustic spectroscopy (OFC-PAS). OFC-PAS combines the broad spectral coverage and the high resolution of OFCs with the small sample volume of cantilever-enhanced PA detection. In OFC-PAS, a Fourier transform spectrometer (FTS) is used to modulate the intensity of the exciting comb source at a frequency determined by its scanning speed. One of the FTS outputs is directed to the PA cell and the other is measured simultaneously with a photodiode and used to normalize the PA signal. The cantilever-enhanced PA detector operates in a non-resonant mode, enabling detection of broadband frequency response. The broadband and the high-resolution capabilities of OFC-PAS are demonstrated by measuring the rovibrational spectra of the fundamental C-H stretch band of CH${_4}$, with no instrumental line shape distortions, at total pressures of 1000 mbar, 650 mbar, and 400 mbar. In this first demonstration, a spectral resolution two orders of magnitude higher than previously reported with broadband PAS is obtained, limited by the pressure broadening. A limit of detection of 0.8 ppm of methane in N${_2}$ is accomplished in a single interferogram measurement (200 s measurement time, 1000 MHz resolution, 1000 mbar total pressure) for an exciting power spectral density of 42 μW/cm${^{-1}}$. A normalized noise equivalent absorption of 8x10${^{-10}}$ W cm${^{-1}}$ Hz${^{-1/2}}$ is obtained, which is only a factor of three higher than the best reported with PAS based on continuous wave lasers. A wide dynamic range of up to four orders of magnitude and a very good linearity (limited by the Beer-Lambert law) over two orders of magnitude are realized. OFC-PAS extends the capability of optical sensors for multispecies trace gas analysis in small sample volume with high resolution and selectivity.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑