Overview of the spectrometer optical fiber feed for the Habitable-zone Planet Finder
Shubham Kanodia, Suvrath Mahadevan, Lawrence. W. Ramsey, Gudmundur K. Stefansson, Andrew J. Monson, Frederick R. Hearty, Scott Blakeslee, Emily Lubar, Chad F. B… 展开作者
Shubham Kanodia, Suvrath Mahadevan, Lawrence. W. Ramsey, Gudmundur K. Stefansson, Andrew J. Monson, Frederick R. Hearty, Scott Blakeslee, Emily Lubar, Chad F. Bender, J. P. Ninan, David Sterner, Arpita Roy, Samuel P. Halverson, Paul M. Robertson
备注:
Presented at 2018 SPIE Astronomical Telescopes + Instrumentation, Austin, Texas, USA. 18 pages, 25 figures, and 2 tables
The Habitable-zone Planet Finder (HPF) is a highly stabilized fiber fed precision radial velocity (RV) spectrograph working in the Near Infrared (NIR): 810 - 1280 nm . In this paper we present an overview of the preparation of the optical fibers for HPF. The entire fiber train from the telescope focus down to the cryostat is detailed. We also discuss the fiber polishing, splicing and its integration into the instrument using a fused silica puck. HPF was designed to be able to operate in two modes, High Resolution (HR- the only mode mode currently commissioned) and High Efficiency (HE). We discuss these fiber heads and the procedure we adopted to attach the slit on to the HR fibers.
The Herschel SPIRE Fourier Transform Spectrometer Spectral Feature Finder IV. Neutral Carbon Detection in the SPIRE FTS Spectra
SPIRE FTS光谱特征拟合程序(FF)由赫歇尔光谱和光度成像接收器(SPIRE)傅立叶变换光谱仪(FTS)仪器团队开发,是一种自动化光谱特征拟合程序,试图在SPIRE FTS光谱中找到重要特征。$^3$ P $_1$ - $^3$ P $_0$和$^3$ P $_2$ - $^3$ P $_1$中性碳精细结构线是富碳远红外天体物理源的共同特征。这些特征可能难以使用自动特征检测例程来检测,这是由于它们通常是低幅度和线混合。在本文中,我们描述和验证FF子例程设计检测中性碳排放SPIRE光谱数据中观察到的。
The Habitable Zone Planet Finder: A Proposed High Resolution NIR Spectrograph for the Hobby Eberly Telescope to Discover Low Mass Exoplanets around M Dwarfs
The Habitable-zone Planet Finder Calibration System
我们提出了宜居带行星探测仪(HPF)的波长校准系统的设计概念,HPF是一个精密的径向速度(RV)摄谱仪,旨在探测M矮星周围的地球质量的行星。HPF是一种稳定的光纤馈入式R $\sim$ 50,000摄谱仪,工作在0.84至1.3微米的近红外(NIR)z/Y/J波段。对于HPF实现1 m s $^{-1}$或更好的测量精度,将需要一个独特的校准系统,稳定到几倍更好的精度,以准确地消除仪器的影响,在一个前所未有的水平在近红外。主要的波长校准源是一个激光频率梳(LFC),目前正在开发中的NIST博尔德,在这些会议记录中单独讨论。LFC将由稳定的单模光纤法布里-珀罗干涉仪参考源和铀霓虹灯补充。HPF校准系统将结合宾夕法尼亚州立大学光学红外仪器组开发的其他几项新技术,以提高RV测量精度,包括动态光学耦合系统,可显著降低模态噪声效应。每个组件都在实验室进行了全面测试,并显示出比以前的近红外校准系统有显着的性能增益。
The Herschel SPIRE Fourier Transform Spectrometer Spectral Feature Finder II. Estimating Radial Velocity of SPIRE Spectral Observation Sources
Herschel SPIRE FTS光谱特征探测器(FF)探测SPIRE光谱中的重要光谱特征,并采用两个例程和外部参考来估计源径向速度。第一个程序是基于旋转CO发射的识别,第二个互相关检测到的功能与线模板包含在典型的远红外观测的大部分特征线。在本文中,我们概述和验证这些例程,总结的结果,因为它们涉及到FF,并评论如何外部参考文献被纳入。
Broadband stability of the Habitable Zone Planet Finder Fabry-Pérot etalon calibration system: evidence for chromatic variation
白光照明的法布里-珀罗标准具的梳状光谱可以作为精确多普勒测量的成本效益和稳定的参考。了解这些器件在其宽光谱带宽(100 nm)范围内的稳定性对于实现其作为多普勒校准器的全部潜力至关重要。然而,公开的描述仍然限于小带宽或短时间跨度。我们提出了一个$\sim6$月的宽带稳定性监测活动的法布里-珀罗标准具系统部署的近红外宜居带行星光谱仪(HPF)。我们监测的$\sim3500$谐振模式中的每一个的波长测量HPF光谱的法布里-珀罗标准具(自由光谱范围= 30 GHz,带宽= 820 - 1280纳米),利用电光频率梳参考的准确性和精度。这些结果揭示了色结构的法布里-珀罗模式的位置,并在其随时间的演变。我们测量的平均漂移为2 cm s $^{-1}$ d $^{-1}$,局部偏差高达$\pm5$ cm s $^{-1}$ d $^{-1}$。我们讨论了这些行为的背景下的法布里-珀罗标准具镜色散和其他光学性质的系统,以及使用类似的系统进行精确的多普勒测量的影响。我们的结果表明,该系统支持HPF的波长校准在$\lesssim10$ cm s $^{-1}$水平超过一夜,并在$\lesssim30$ cm s $^{-1}$水平超过$\sim10$ d。我们的研究结果还强调了需要长期和光谱分辨的类似系统,将部署到支持多普勒测量精度接近$\sim10$厘米秒$^{-1}$的研究。
A Versatile Technique to Enable sub-milli-Kelvin Instrument Stability for Precise Radial Velocity Measurements: Tests with the Habitable-zone Planet Finder
The Breakthrough Listen Search for Intelligent Life: No Evidence of Claimed Periodic Spectral Modulations in High Resolution Optical Spectra of Nearby Stars
Direct In-Situ Capture, Separation and Visualization of Biological Particles with Fluid-Screen in the Context of Venus Life Finder Mission Concept Study
Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared Calibration Sources for High Resolution Spectrographs
我们讨论了单模光纤法布里-珀罗(FFP)干涉仪作为高精度径向速度(RV)光谱仪的精确天文光子校准源的持续发展。FFP是简单、廉价的单片单元,可以产生稳定和可重复的输出光谱。FFP是传统标准具的独特替代品,因为干涉腔由单模光纤而不是气隙间隔器制成。这种设计允许出色的准直,高光谱精细度,刚性机械稳定性,对振动不敏感,并且不需要真空操作。我们测试的设备是Micron Optics的市售产品。我们的发展道路是针对校准源的可扩展区行星光谱仪(HPF),近红外光谱仪,旨在检测低质量恒星周围的地球质量行星,但这个参考也可以用于许多现有的和计划中的光纤光谱仪,因为我们说明使用Apache点天文台星系演化实验(APOGEE)仪器。通过对光纤标准具的精确温度控制,我们实现了100 $μ$ K的热稳定性和22 cm s $^{-1}$的相关速度不确定性。我们实现了$\approx$ 2 m s $^{-1}$的精度在一个单一的APOGEE光纤超过12小时,使用这个新的光子参考后,删除系统的相关性。这种高精度(接近预期的光子极限下限)证明了光纤干涉仪出色的固有波长稳定性和APOGEE仪器设计的稳定性。当在所有300个APOGEE光纤上取平均值并去除已知趋势和压力相关性后,12小时内的总体仪器速度精度为80 cm s $^{-1}$,这意味着光纤标准具在本质上稳定到显著更高的精度。
SUPERSHARP - Segmented Unfolding Primary for Exoplanet Research via Spectroscopic High Angular Resolution Photography
我们建议从大约100个地球大小的行星反射光的光谱中寻找生物特征,这些行星已经知道在它们的宜居带(HZ)中运行。对于G型和K型宿主的样本,这些行星中的大多数将与它们的宿主恒星相距25至50毫角秒(mas),并且暗10亿至100亿倍。为了在氧生物特征的波长(763纳米)处将行星的图像与其宿主恒星的图像分开,我们需要一个孔径为16米的望远镜。此外,在系外行星图像中的位置,来自主恒星的光的强度必须被抑制,否则系外行星将在眩光中消失。这带来了巨大的技术挑战。地球的大气层是湍流的,这使得它不可能在763 nm的地面上达到所需的对比度。因此,望远镜需要在太空中,为了将望远镜安装在火箭整流罩中,它必须在折叠时比工作时小4倍或更多倍。为了获得763 nm处的行星生物特征光谱,我们需要使用一个视场(FOV)为1000 x 1000毫角秒(mas)和光谱分辨率为100的积分场光谱仪(IFS)。这是一种设备,可以同时拍摄系外行星的许多照片,每张照片的波长略有不同,然后记录为具有两个空间维度和一个波长维度的数据立方体。在每一个数据立方体波长切片中,来自行星图像所在位置的主星的背景光必须最小化。这是通过阻挡来自主星的光的日冕仪和持续保持非常高精度的光学对准以使图像尽可能清晰的主动/自适应光学技术来实现的。这些都是设计研究中需要解决的技术挑战。