NEID光谱仪的超稳定环境控制:设计和性能验证

Ultra-Stable Environment Control for the NEID Spectrometer: Design and Performance Demonstration

Paul Robertson, Tyler Anderson, Gudmundur Stefansson, Frederick R. Hearty, Andrew Monson, Suvrath Mahadevan, Scott Blakeslee, Chad Bender, Joe P. Ninan, David C… 展开作者

Paul Robertson, Tyler Anderson, Gudmundur Stefansson, Frederick R. Hearty, Andrew Monson, Suvrath Mahadevan, Scott Blakeslee, Chad Bender, Joe P. Ninan, David Conran, Eric Levi, Emily Lubar, Amanda Cole, Adam Dykhouse, Shubham Kanodia, Colin Nitroy, Joseph Smolsky, Demetrius Tuggle, Basil Blank, Matthew Nelson, Cullen Blake, Samuel Halverson, Chuck Henderson, Kyle F. Kaplan, Dan Li, Sarah E. Logsdon, Michael W. McElwain, Jayadev Rajagopal, Lawrence W. Ramsey, Arpita Roy, Christian Schwab, Ryan Terrien, Jason T. Wright

摘要:

当代实验性系外行星科学的两个重点领域是凌日类地行星的详细特征,以及寻找未来成像任务的目标地球类地行星。这两种追求都依赖于恒星径向速度(RV)测量的数量级改进,要求单次测量仪器的不确定度为10 cm/s。要在高分辨率光谱仪上实现如此非凡的精度,需要将仪器的热机械稳定性提高到前所未有的水平。本文介绍了NEID光谱仪的环境控制系统(ECS),该系统将于2019年在Kitt Peak国家天文台3.5 m WIYN望远镜上投入使用,其性能指标为天内RV精度< 50 cm/s。由于NEID的光学工作台和底座是由铝制成的,而铝具有很高的热膨胀系数,因此亚毫开尔文温度控制尤为关键。NEID继承了其ECS从可压缩区行星轨道(HPF),但与改进的性能和操作接近室温的修改。我们的全系统稳定性测试表明,NEID系统超过了HPF已经令人印象深刻的性能,在30天内保持真空压力低于$10^{-6}$ Torr,RMS温度稳定性优于0.4 mK。我们的ECS设计是完全开源的;我们的温控真空室的设计已经公开,在这里我们发布了我们定制的温度监测和控制(TMC)系统的电气原理图。

英文摘要:

Two key areas of emphasis in contemporary experimental exoplanet science are the detailed characterization of transiting terrestrial planets, and the search for Earth analog planets to be targeted by future imaging missions. Both of these pursuits are dependent on an order-of-magnitude improvement in the measurement of stellar radial velocities (RV), setting a requirement on single-measurement instrumental uncertainty of order 10 cm/s. Achieving such extraordinary precision on a high-resolution spectrometer requires thermo-mechanically stabilizing the instrument to unprecedented levels. Here, we describe the Environment Control System (ECS) of the NEID Spectrometer, which will be commissioned on the 3.5 m WIYN Telescope at Kitt Peak National Observatory in 2019, and has a performance specification of on-sky RV precision < 50 cm/s. Because NEID's optical table and mounts are made from aluminum, which has a high coefficient of thermal expansion, sub-milliKelvin temperature control is especially critical. NEID inherits its ECS from that of the Habitable-zone Planet Finder (HPF), but with modifications for improved performance and operation near room temperature. Our full-system stability test shows the NEID system exceeds the already impressive performance of HPF, maintaining vacuum pressures below $10^{-6}$ Torr and an RMS temperature stability better than 0.4 mK over 30 days. Our ECS design is fully open-source; the design of our temperature-controlled vacuum chamber has already been made public, and here we release the electrical schematics for our custom Temperature Monitoring and Control (TMC) system.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑