为了满足通用反粒子谱仪(GAPS)实验的特殊要求,研制了一种Si(Li)探测器的制作工艺。Si(Li)探测器特别适合于GAPS探测方案,其中几个探测器平面作为目标,以减缓和捕获进入奇异原子的反粒子,以及光谱仪和跟踪器来测量产生的衰变X射线和湮灭产物。这些探测器必须提供这种技术所需的吸收深度、能量分辨率、跟踪效率和有效面积,所有这些都在南极长期气球飞行的显著温度、功率和成本限制范围内。我们在这里报告的原型2”直径,1-1.25毫米厚,单条硅(锂)探测器的制造和性能,提供必要的X射线能量分辨率为$\sim$ 4 keV的单位面积的成本远低于以前获得的商业探测器。目前正在对这种制造程序进行优化,以用于GAPS飞行探测器的4”直径、2.5 mm厚、多条几何形状。
英文摘要:
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1-1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of $\sim$4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. This fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.