In 2017, the LHC (Large Hadron Collider) at CERN has obtained an astonishing result providing proton-proton collisions with an integrated luminosity of 50.25 fb-1. The CMS (Compact Muon Solenoid), a general-purpose detector operating at the LHC, has been able to record 45.39 fb-1. ECAL (Electromagnetic Calorimeter), has shown a good performance with a very stable DAQ (Data Acquisition) system even during higher LHC luminosity peaks. This has been partly because of the electronics auto-recovery system that has been developed to identify errors like SEU (Single Event Upset) and to resolve them. A new monitoring system has been developed called ecalView which is used for monitoring the errors from different electronics of the ECAL and to keep a log of these errors in a database for future reference.
The CMS electromagnetic calorimeter (ECAL) is a high-resolution, hermetic, and homogeneous calorimeter made of 75,848 scintillating lead tungstate crystals. Following the discovery of the Higgs boson, the CMS ECAL is at the forefront of precision measurements and the search for new physics in data from the LHC, which recently began producing collisions at the unprecedented energy of 13 TeV. The exceptional precision of the CMS ECAL, as well as its timing performance, are invaluable tools for the discovery of new physics at the LHC Run 2. The excellent performance of the ECAL relies on precise …
While the CMS experiment is currently harvesting LHC collision data at CERN, the performance of its electromagnetic calorimeter (ECAL) is being constantly monitored, and work has started to assess the need for changes to the detector to ensure an adequate performance for High-Luminosity LHC (HL-LHC) running, which is planned for 2022 and beyond. In this paper, results from CMS running, beam tests and laboratory measurements are combined to anticipate the detector performance evolution at the HL-LHC. Further, various R&D studies are illustrated, that will provide a useful choice for electromagn…
High-Luminosity running at the LHC, which is planned for 2022 and beyond, will imply an order of magnitude increase in radiation levels and particle fluences with respect to the present LHC running conditions. The performance evolution of the CMS electromagnetic calorimeter (ECAL), comprising 75,848 scintillating lead tungstate crystals, indicates that an upgrade of its endcaps will be needed for HL-LHC running, to ensure an adequate performance. Results from LHC collision periods, beam tests and laboratory measurements of proton-irradiated crystals are combined to predict the performance of t…
The CMS Electromagnetic Calorimeter (ECAL) is a high resolution crystal calorimeter operating at the CERN LHC. It is responsible for the identification and precise reconstruction of electrons and photons in CMS, which were crucial in the discovery and subsequent characterization of the Higgs boson. It also contributes to the reconstruction of tau leptons, jets, and calorimeter energy sums, which are vital components of many CMS physics analyses. The ECAL trigger system employs fast digital signal processing algorithms to precisely measure the energy and timing information of ECAL energy deposi…
CMS ECAL physicists must be able to extract physics characteristics from the ECAL construction database for the calibration of sets of detector components. Other applications, such as geometry for simulation and physics event reconstruction, will also need to extract data from the construction database. In each case, application software needs to query the construction database and to extract data that satisfies a particular view. These viewpoints are defined for a specific purpose (e.g. simulation, slow control, calibration) and data must be extracted into the viewpoint for a set of defined d…
ETH Zurich(苏黎世联邦理工学院);INFN(意大利国家核物理研究所);Università degli studi di Milano-Bicocca(米兰比可卡大学)
The reconstruction of electrons and photons in CMS depends on topological clustering of the energy deposited by an incident particle in different crystals of the electromagnetic calorimeter (ECAL). These clusters are formed by aggregating neighbouring crystals according to the expected topology of an electromagnetic shower in the ECAL. The presence of upstream material (beampipe, tracker and support structures) causes electrons and photons to start showering before reaching the calorimeter. This effect, combined with the 3.8T CMS magnetic field, leads to energy being spread in several clusters…
A description is provided of the performance of the CMS detector for photon reconstruction and identification in proton-proton collisions at a centre-of-mass energy of 8 TeV at the CERN LHC. Details are given on the reconstruction of photons from energy deposits in the electromagnetic calorimeter (ECAL) and the extraction of photon energy estimates. The reconstruction of electron tracks from photons that convert to electrons in the CMS tracker is also described, as is the optimization of the photon energy reconstruction and its accurate modelling in simulation, in the analysis of the Higgs bos…
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these reasons the electronics readout has been completely redesigned. A dual gain trans-impedance amplifier and an ASIC providing two 160 MHz ADC channels, gain selection, and data compression will be used…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energ…
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
Although CMS will not start operation for several years, many subdetector groups have active testbeam programs involving final or near-final electronics. The high-bandwidth electronics require the development of new DAQ systems including hardware and software. This paper presents the design and performance of the DAQ software used for the summer 2002 HCAL testbeam at CERN. This system successfully acquired over 80M testbeam events, running at rate of 200-1000 Hz. The paper also describes some of the developments made for the 2003 testbeam, including the integration of the CMS xDAQ framework.
We give an overview of the main features of the CMS trigger and data acquisition (DAQ) system. Then, we illustrate the strategies and trigger configurations (trigger tables) developed for the detector calibration and physics program of the CMS experiment, at start-up of LHC operations, as well as their possible evolution with increasing luminosity. Finally, we discuss the expected CPU time performance of the trigger algorithms and the CPU requirements for the event filter farm at start-up.
The Pixel Detector is the innermost part of the CMS Tracker. It therefore has to prevail in the harshest environment in terms of particle fluence and radiation. There are several mechanisms that may decrease the efficiency of the detector. These are mainly caused by data acquisition (DAQ) problems and/or Single Event Upsets (SEU). Any remaining efficiency loss is referred to as the dynamic inefficiency. It is caused by various mechanisms inside the Readout Chip (ROC) and depends strongly on the data occupancy. In the 2012 data, at high values of instantaneous luminosity the inefficiency reache…
Throughout the year 2011, the Large Hadron Collider (LHC) has operated with an instantaneous luminosity that has risen continually to around 4x10^33cm-2 s-1. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS) experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 106. The first level (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger …
The High-Luminosity LHC (HL-LHC) will usher in a new era in high-energy physics. The HL-LHC experimental conditions entail an instantaneous luminosity of up to $7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ and up to 200 simultaneous collisions per bunch crossing (pileup). To cope with those conditions, the CMS detector will undergo a series of improvements, in what is known as the Phase-2 upgrade. In particular, the upgrade of the Data Acquisition and of the High-Level Trigger (DAQ-HLT) will have to address a much higher event rate and more complex events. In this paper, we will discuss the aspects …
A study of the electron identification and selection efficiency of the L1 Trigger algorithm has been performed using the combined ECAL/HCAL test beam data. A detailed discussion of the electron isolation and its impact on the selection efficiency is presented. The L1 electron algorithm is studied for different beam energies and the results indicate that efficiencies of 98% or more can be achieved for electrons with energies between 15 and 100 GeV. The fraction of charged hadrons with energies from 3 up to 100 GeV rejected by the L1 electron trigger algorithm is estimated to be larger than 93%.
We have exposed seven full length production quality crystals of the electromagnetic calorimeter (ECAL) of the CMS detector to a 20 GeV/c proton beam at the CERN PS accelerator. The exposure was done at fluxes of 10**12 p/cm**2/h and 10**13 p/cm**2/h and integral fluences of 10**12 p/cm**2 and 10**13 p/cm**2 were reached at both rates. The light transmission of the crystals was measured after irradiation and suitable cooling time for induced radioactivity to decrease to a safe level. First results of these measurements are shown. The possible damage mechanisms are discussed and simulations bas…
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam…