本文研究分布式发电在暂态故障下对SAIFI可靠性指标的负面影响,通过网络建模展示故障影响机制,发现不当的DG安装位置和继电保护设置会导致可靠性下降。

摘要:

本文揭示了分布式发电在配电网络中因暂态故障而对SAIFI可靠性指标产生负面影响的潜在问题。通过详细的网络建模进行准确的时域仿真,展示了可靠性指标下降的具体机制。问题源于因DG安装位置不当和继电保护设置不合理导致的熔断器断开。选取了一个4kV的城市配电系统进行分析。在研究的网络中,超过50%的可能DG安装位置会导致可靠性降低。

英文摘要:

This paper uncovers potential negative impacts on the SAIFI reliability index produced by the installation of Distributed Generation (DG) in distribution networks when subjected to temporary faults. Detailed network modeling produces accurate time-domain simulations which show how the negative effects on reliability index occur. The problem is caused by fuse opening due to the wrong location of the DG and unsuitable relay settings. A 4 kV urban distribution system is chosen for the analysis. Over 50% of the possible locations where DG can be installed in the network under study yield reduce reliability.