使用基于高斯过程的模块贝叶斯方法的逆不确定性量化,第2部分:应用于TRACE
Inverse Uncertainty Quantification using the Modular Bayesian Approach based on Gaussian Process, Part 2: Application to TRACE
摘要:
逆不确定性量化(UQ)是量化随机输入参数中的不确定性同时实现代码模拟与物理观测之间的一致性的过程。在本文中,我们进行了反UQ使用改进的模块贝叶斯方法的基础上高斯过程(GP)的TRACE物理模型参数使用BWR全尺寸细网格束试验(BFBT)基准稳态空隙率数据。用GP仿真器描述了模型差异。数值试验表明,这种对模型偏差的处理可以避免过拟合。在此基础上,构建了一个运行速度快、精度高的GP仿真器来代替马尔可夫链蒙特卡罗(MCMC)采样过程中的TRACE全模型。计算成本被证明是减少了几个数量级。一个顺序的方法也被开发为有效的测试源分配(TSA)的逆UQ和验证。该顺序TSA方法首先选择实验测试进行验证,该实验测试具有测试域的完全覆盖,以避免在逆UQ测试的输入设置处进行评估时模型差异项的外推。然后,它选择的测试,往往驻留在测试域的未填充区的逆UQ,这样就可以提取的校准参数的后验概率分布的信息,只有相对较少的测试数量。该研究解决了TRACE物理输入参数“缺乏输入不确定性信息”的问题,在以前的工作中,该问题通常被忽略或使用专家意见或用户自评估来描述。所得到的TRACE参数的后验概率分布可用于未来TRACE程序的不确定性、灵敏度和验证研究,用于核反应堆系统设计和安全分析。
英文摘要:
Inverse Uncertainty Quantification (UQ) is a process to quantify the uncertainties in random input parameters while achieving consistency between code simulations and physical observations. In this paper, we performed inverse UQ using an improved modular Bayesian approach based on Gaussian Process (GP) for TRACE physical model parameters using the BWR Full-size Fine-Mesh Bundle Tests (BFBT) benchmark steady-state void fraction data. The model discrepancy is described with a GP emulator. Numerical tests have demonstrated that such treatment of model discrepancy can avoid over-fitting. Furthermore, we constructed a fast-running and accurate GP emulator to replace TRACE full model during Markov Chain Monte Carlo (MCMC) sampling. The computational cost was demonstrated to be reduced by several orders of magnitude. A sequential approach was also developed for efficient test source allocation (TSA) for inverse UQ and validation. This sequential TSA methodology first selects experimental tests for validation that has a full coverage of the test domain to avoid extrapolation of model discrepancy term when evaluated at input setting of tests for inverse UQ. Then it selects tests that tend to reside in the unfilled zones of the test domain for inverse UQ, so that one can extract the most information for posterior probability distributions of calibration parameters using only a relatively small number of tests. This research addresses the "lack of input uncertainty information" issue for TRACE physical input parameters, which was usually ignored or described using expert opinion or user self-assessment in previous work. The resulting posterior probability distributions of TRACE parameters can be used in future uncertainty, sensitivity and validation studies of TRACE code for nuclear reactor system design and safety analysis.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。