A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024 %. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058 %. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.
Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized $^{3}$He neutron spin-filter
Results for the response function determination of the Compact Neutron Spectrometer
紧凑型中子谱仪(CNS)是一个联合欧洲环(JET)增强项目,设计用于不同等离子体场景下的聚变诊断。CNS基于液体闪烁体(BC 501 A),可以很好地区分中子和伽马辐射。使用BC 501 A谱仪进行中子能谱测量需要使用可靠的、完全表征的探测器。响应矩阵的测定在联邦物理技术研究所(PTB)的离子加速器设施(PIAF)进行。该设施提供了几个单能束(2.5,8,10,12和14 MeV)和一个“白场”(Emax ~17 MeV),这使得光谱仪在感兴趣的区域(从~1.5 MeV到~17 MeV)的全面表征成为可能。入射中子的能量由飞行时间方法(TOF)确定,时间分辨率为1 ns。为了检查响应矩阵,测量的脉冲高度谱展开与代码MAXED和由此产生的能量分布从TOF得到的那些进行了比较。CNS项目需要修改PTB BC 501 A光谱仪的设计,用Ente per le Nuove tecnologie,l 'Energia e l' Ambiente '(ENEA)开发的数字系统取代模拟数据采集系统(NIM模块)。使用专门为此项目开发的新软件对新数字系统的结果进行了评估。
Application of the Monte-Carlo refractive index matching (MCRIM) technique to the determination of the absolute light yield of a calcium molybdate scintillator
40 Ca 100 MoO在无中微子双β衰变(0νDBD)实验研究中的应用依赖于对该材料基本闪烁特性的了解。在这项工作中,我们确定的绝对光产额的钙离子使用蒙特卡罗折射率匹配技术(MCRIM)。MCRIM技术是实验和模拟的结合,允许通过考虑材料中的折射、散射和吸收的影响来确定反射器的绝对光产额。使用ZEMAX光线跟踪软件模拟了反射器-检测器组件的光收集效率。通过调节闪烁晶体的光学参数,推导出了与实验结果吻合较好的模型。结果表明,由于光子逃逸晶体体积的概率增加,光收集效率的增加与透射率和散射。用MCRIM测得40 Ca_(100)MoO_4闪烁体在室温下的绝对光产额为7.5 ± 1.2ph/keV。使用CaWO 4闪烁体作为参考的比较测量显示与该结果良好的一致性。通过这种方式,该研究证明了MCRIM技术作为闪烁材料定量表征工具的潜力。
Unambiguous determination of structure parameters for soft matter samples made possible with polarization analysis on JCNS SANS using a 3He spin filter