arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1709.08829astro-ph.IM
收藏

Hitomi(ASTRO-H)上软X射线成像系统的在轨性能

In-orbit performance of the soft X-ray imaging system aboard Hitomi (ASTRO-H)

H. Nakajima, Y. Maeda, H. Uchida, T. Tanaka, H. Tsunemi, K. Hayashida, T. G. Tsuru, T. Dotani, R. Nagino, S. Inoue, M. Ozaki, H. Tomida, C. Natsukari, S. Ueda, … 展开作者

H. Nakajima, Y. Maeda, H. Uchida, T. Tanaka, H. Tsunemi, K. Hayashida, T. G. Tsuru, T. Dotani, R. Nagino, S. Inoue, M. Ozaki, H. Tomida, C. Natsukari, S. Ueda, K. Mori, M. Yamauchi, I. Hatsukade, Y. Nishioka, M. Sakata, T. Beppu, D. Honda, M. Nobukawa, J. S. Hiraga, T. Kohmura, H. Murakami, K. K. Nobukawa, A. Bamba, J. P. Doty, R. Iizuka, T. Sato, S. Kurashima, N. Nakaniwa, R. Asai, M. Ishida, H. Mori, Y. Soong, T. Okajima, P. Serlemitsos, Y. Tawara, I. Mitsuishi, K. Ishibashi, K. Tamura, T. Hayashi, A. Furuzawa, S. Sugita, T. Miyazawa, H. Awaki, E. D. Miller, H. Yamaguchi

摘要:

介绍了由软X射线望远镜和软X射线成像仪组成的软X射线成像系统的在轨性能。对成像和光谱性能进行了核查和校准,最大限度地利用了不到三周的有限数据。包括38'x38'大视场的基本性能通过英仙座星系团的第一张光图像得到验证。在观测到的少数目标中,蟹状星云脉冲星的时间外事件的开关脉冲图像使我们能够测量望远镜的半功率直径约为1.3 '。在5.89 keV的板载校准源事件测量的平均能量分辨率为179 pm 3 eV的半高全宽。光泄漏和串扰问题分别影响有效曝光时间和有效面积,因为所有的观察都是在优化暗水平计算的观察时间表和参数之前进行的。通过对受这两个问题影响的数据进行筛选,我们在5-12 keV的能带内测量到本底能级为5.6 × 10 ^{-6}计数s^{-1} arcmin^{-2} cm^{-2},比朱雀XIS-BI的本底能级低7倍。

英文摘要:

We describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out making the best use of the limited data of less than three weeks. Basic performance including a large field of view of 38'x38' is verified with the first light image of the Perseus cluster of galaxies. Amongst the small number of observed targets, the on-minus-off pulse image for the out-of-time events of the Crab pulsar enables us to measure a half power diameter of the telescope as about 1.3'. The average energy resolution measured with the onboard calibration source events at 5.89 keV is 179 pm 3 eV in full width at half maximum. Light leak and cross talk issues affected the effective exposure time and the effective area, respectively, because all the observations were performed before optimizing an observation schedule and parameters for the dark level calculation. Screening the data affected by these two issues, we measure the background level to be 5.6x10^{-6} counts s^{-1} arcmin^{-2} cm^{-2} in the energy band of 5-12 keV, which is seven times lower than that of the Suzaku XIS-BI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑