Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.
Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers
与普通物质弱相互作用的粒子,其相关质量为原子核(WIMPs)量级,是暗物质的可能候选者。由这些WIMP之一引起的靶核的弹性碰撞的直接检测必须与由中子产生的信号区分开,中子产生的信号在检测器中留下相同的信号。MIMAC(MIcro-tpc MAGNETIC of Chambers)合作开发了一种原始的原型探测器,该探测器将大型像素化Micromegas与快速自触发电子器件相结合。介绍了Modane地下实验室中运行的双室模块的各个方面:$^{222}$ Rn子体的校准和表征。建立了一个新的实验台,它结合了MIMAC室和COMIMAC便携式淬火线,用于表征MIMAC混合气体中低能离子的三维径迹:给出了初步结果。简要讨论了今后的步骤。
He-CF4-CH4 ternary mixtures as target gas for the CYGNO directional dark matter experiment
University of Coimbra(科英布拉大学);Universit`a Roma TRE(罗马三所大学);Istituto Nazionale di Fisica Nucleare(意大利国家核物理研究所;罗马三分所);Sezione di Roma Tre(格兰萨索科学研究所);Gran Sasso Science Institute(意大利国家核物理研究所;格兰萨索国家实验室);Istituto Nazionale di Fisica Nucleare(意大利国家核物理研究所;弗拉斯卡蒂国家实验室);Laboratori Nazionali del Gran Sasso(意大利国家新科技、能源和可持续经济发展局弗拉斯卡蒂研究中心);Istituto Nazionale di Fisica Nucleare(茹伊斯迪福拉联邦大学);Laboratori Nazionali di Frascati(罗马大学);ENEA Centro Ricerche Frascati(意大利国家核物理研究所;罗马分所);Universidade Federal de Juiz de Fora(罗马大学);Universit`a di Roma Sapienza(谢菲尔德大学);Istituto Nazionale di Fisica Nucleare;Sezione di Roma;Sapienza Universit`a di Roma;University of Sheffield
Bayesian network 3D event reconstruction in the Cygno optical TPC for dark matter direct detection
University of Coimbra(科英布拉大学);Istituto Nazionale di Fisica Nucleare, Sezione di Roma TRE(意大利国家核物理研究所罗马三分部);Gran Sasso Science Institute(格兰萨索科学研究所);Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所格兰萨索国家实验室);Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati(意大利国家核物理研究所弗拉斯卡蒂国家实验室);Istituto Nazionale di Fisica Nucleare, Sezione di Roma(意大利国家核物理研究所罗马分部);ENEA Centro Ricerche Frascati(意大利国家新科技、能源和可持续经济发展局弗拉斯卡蒂研究中心);Universidade Estadual de Campinas - UNICAMP(坎皮纳斯州立大学);University of Sheffield(谢菲尔德大学);Universidade Federal de Juiz de Fora(茹伊斯德福拉联邦大学)
A Large-Area Optical Time Projection Chamber for Hard X-ray Polarimetry with Directional Imaging of Low-Energy Electron Recoils
Gran Sasso Science Institute(格兰萨索科学研究所);INFN Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所大萨索国家实验室);INFN Laboratori Nazionali di Frascati(意大利国家核物理研究所弗拉斯卡蒂国家实验室);IAPS - INAF Istituto di Astrofisica e Planetologia Spaziali(空间天体物理学和行星学研究所-意大利国家天体物理研究所)
MIMAC low energy electron-recoil discrimination measured with fast neutrons
MIMAC(MIcro-TPC MATERIAL of Chambers)是一个定向WIMP暗物质探测器项目。直接的暗物质实验需要高水平的电子/反冲鉴别来寻找由WIMP-核弹性散射产生的核反冲。在本文中,我们提出了一个原始的方法,电子事件拒绝的基础上,应用于实验数据采集单色中子场的多元分析。该分析表明,$10^5$抑制功率对于电子/反冲辨别是可达到的。此外,通过蒙特卡罗模拟估计效率,表明在考虑全能量范围的情况下,利用$86.49\pm 0.17$ \%的核反冲效率达到105电子排斥功率,并且在考虑5 keV的低阈值的情况下,利用$94.67\pm0.19$ \%的核反冲效率达到105电子排斥功率。