参数化质子射程模型的精确度;比较
Accuracy of parameterized proton range models; a comparison
摘要:
在体模或探测器几何结构中准确计算质子范围对于质子治疗和质子成像中的决策至关重要。为此目的,存在几种范围-能量关系的参数化,具有不同程度的复杂性和准确性。在这项研究中,我们比较了四种不同的参数化模型的准确性:两个分析模型来自贝特方程,和两个不同的插值方案适用于范围能量表。总之,样条插值方案产生最高的再现精度,而能量损失曲线的形状是最好的再现与微分布拉格-克莱曼方程。
英文摘要:
An accurate calculation of proton ranges in phantoms or detector geometries is crucial for decision making in proton therapy and proton imaging. To this end, several parameterizations of the range-energy relationship exist, with different levels of complexity and accuracy. In this study we compare the accuracy four different parameterizations models: Two analytical models derived from the Bethe equation, and two different interpolation schemes applied to range-energy tables. In conclusion, a spline interpolation scheme yields the highest reproduction accuracy, while the shape of the energy loss-curve is best reproduced with the differentiated Bragg-Kleeman equation.