用GATE/Geant4、MCNP6和FLUKA计算复杂介质中质子射程的比较
A comparison of proton ranges in complex media using GATE/Geant4, MCNP6 and FLUKA
摘要:
蒙特卡罗(MC)模拟方法是辐射物理学家的强大工具,当今多种通用软件包通常应用于无数不同的辐射物理领域。在医学物理学中,用于质子计算机断层成像的带电粒子探测器正在开发中,这是为了提高质子放射治疗的准确性而引入的一种模式。MC模拟在这种探测器系统的开发和优化阶段是有帮助的。为了证明MC用于这些目的的合理性,必须根据实验或理论数据验证模拟输出,甚至在不同MC软件包之间进行交叉检查。在这项研究中,我们比较了三个通用MC软件包(GATE/Geant 4,MCNP 6和FLUKA),他们如何预测质子的停止位置的空间分布。它们相互比较和半经验数据,使用平均质子范围,纵向和横向变化的个别质子范围,和初级质子丢失的核相互作用的分数。该比较在两种均质材料和为质子计算机断层成像设计的探测器几何结构中进行。三个MC软件包一致,并充分再现半经验数据。观察到一些差异,例如GATE/Geant 4中的横向束扩散较少,以及MCNP 6质子范围在水中的小缺陷:这与先前发表的数据一致。由于普遍的协议,模拟框架的选择可能会根据个人喜好。重要的是要注意,物理包的选择,模拟参数设置和材料定义是执行MC模拟时的重要方面,无论是在模拟结果的准备,执行和解释。
英文摘要:
The Monte Carlo (MC) simulation method is a powerful tool for radiation physicists, and several general-purpose software packages are commonly applied in a myriad of different radiation physics fields today. In medical physics, charged particle detectors for proton Computed Tomography are under development, a modality introduced in order to increase the accuracy of proton radiation therapy. MC simulations are helpful during the development and optimization phase of such detector systems. In order to justify the usage of MC for such purposes, the simulation output must be validated against experimental or theoretical data, or even cross-checked between different MC software packages. In this study, we compare three general-purpose MC software packages (GATE/Geant4, MCNP6 and FLUKA) with respect to how they predict the spatial distribution of the stopping position of protons. They are compared to each other and to semi-empirical data, using the mean proton range, the longitudinal and lateral variation of individual proton ranges, and the fraction of primary protons lost to nuclear interactions. This comparison is performed in two homogeneous materials and in a detector geometry designed for proton Computed Tomography. The three MC software packages agree well, and sufficiently reproduce the semi-empirical data. Some discrepancies are observed, such as less lateral beam spreading in GATE/Geant4, and a small deficiency in the MCNP6 proton range in water: This is consistent with previously published data. Due to the general agreement, the choice of simulation framework may be made on personal preferences. It is important to note that the choice of physics packages, simulation parameter settings and material definitions are important aspects when performing MC simulations, both during the preparation, execution and interpretation of the simulation results.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。